60
TK 56430-18-IP-EN
S
Sn
na
ap
p o
on
n tth
he
e C
Ca
ag
ge
e
5. Snap the cage into the groove on the nipple. The arms should extend over the hose length. When the cage has been
carefully installed in the cage grove, the cage will be able to rotate in the grove. This step must be performed to
verify:
•
The clips will be located over the O-ring on the nipple.
•
The connection will be compatible with the connection’s pressure rating.
Figure 58.
Cage shown installed into the groove on the nipple.
S
Slliid
de
e tth
he
e C
Clliip
pss
6. Slide the clips over the cage arms and into the channels on each arm.
Figure 59.
Clips shown installed correctly.
C
Cllo
osse
e tth
he
e C
Clliip
pss
7. Use the fitting tool (204-1045 or 204-1128) to close the clips. The tool should be positioned squarely on the clip
connection points and should remain square during the closing of the clip.
•
For easiest assembly, the clasp should be closed between the cage arms.
•
Nose of the tool should be firmly seated under the assembly bump and lock latch.
•
If the tool is not kept square during closing the clip, the clasp may have an offset. Use the tool to correct the
clasp alignment.
Figure 60.
Use the fitting tool to close the clips correctly.