Operating Instructions
55
Examples of Products Normally
Acceptable for CYCLE-SENTRY Operation
•
Frozen foods (in adequately insulated trailers)
•
Boxed or processed meats
•
Poultry
•
Fish
•
Dairy products
•
Candy
•
Chemicals
•
Film
•
All non-edible products.
Examples of Products Normally Requiring
Continuous Run Operation of Air Flow
•
Fresh fruits and vegetables, especially
asparagus, bananas, broccoli, carrots, citrus,
green peas, lettuce, peaches, spinach,
strawberries, sweet corn, etc.
•
Non-processed meat products (unless
pre-cooled to recommended temperature)
•
Fresh flowers and foliage.
The above listings are not all inclusive. Consult
your grower or shipper if you have any questions
above the operating mode selection on your type
of load.
Continuous Run Operation
With the selector switch in the Cont Run position,
the CYCLE-SENTRY unit will operate in its
regular cooling and heating modes. Refer to
“Manually Starting Units on Diesel Operation” on
page 54 or “Starting the Unit—CYCLE-SENTRY
Units on Diesel Operation” on page 54.
CYCLE-SENTRY Operation
With the selector switch placed in the
CYCLE-SENTRY position, the
CYCLE-SENTRY system shuts down the unit
when the compartment temperature reaches the
thermostat setpoint, and restarts the unit on
thermostat demand.
On CYCLE-SENTRY equipped units, the unit
start-ups may also be initiated by Defrost cycle
initiation or engine block temperature switch
demand.
If Defrost is initiated either manually, or
automatically by the defrost timer, the unit will
start and run in Defrost. When the Defrost cycle is
complete, the unit will run in whichever operating
mode the thermostat demands until the
compartment temperature reaches setpoint.
In cold ambients, the CYCLE-SENTRY system
automatically maintains engine temperature by
restarting the unit if the engine block temperature
drops to 30 F (-1 C). When the unit starts up
because of low engine block temperature, the unit
will run in whichever operating mode the unit
thermostat is calling for until the battery is fully
charged and the engine block temperature rises to
90 F (32 C).
After the unit starts from thermostat demand,
Defrost initiation, or engine block temperature
switch demand, a Battery Sentry switch monitors
the voltage across the field of the alternator and
will keep the unit running until the battery is
recharged sufficiently. The unit runs in whichever
operating mode the thermostat demands to
properly maintain the compartment temperature.
When the battery is sufficiently recharged, the
unit will shut down on thermostat demand.
NOTE: A buzzer sounds when the unit is
automatically preheating.
CAUTION: With the Auto Start/Stop -
Continuous Run switch in the
CYCLE-SENTRY position and the On/Off
switches in the On position, The unit may
start at any time without prior warning.
Содержание MD-MT
Страница 4: ...4...
Страница 10: ...Table of Contents 10...
Страница 22: ...Specifications 22...
Страница 41: ...Unit Description 41 Unit Photographs Figure 12 Roadside View Figure 13 Curbside View ARD024 ARD025...
Страница 43: ...Unit Description 43 Figure 15 Engine Side Door Open ARD041...
Страница 48: ...Unit Description 48...
Страница 128: ...Refrigeration Service Operations 128...
Страница 134: ...Hilliard Clutch Maintenance 134...
Страница 136: ...Structural Maintenance 136...
Страница 148: ...Refrigeration Diagnosis 148...
Страница 150: ...Remote Evaporator Specifications 150...
Страница 152: ...Remote Evaporator Maintenance Inspection Schedule 152...
Страница 156: ...Remote Evaporator Unit Description 156...
Страница 160: ...Remote Evaporator Structural Maintenance 160...
Страница 162: ...Remote Evaporator System Diagnosis 162...
Страница 166: ...Wiring and Schematic Diagrams Index 166...
Страница 167: ...167 MD RD MT Model 30 w In Cab Schematic Diagram Page 1 of 2...
Страница 168: ...168 MD RD MT Model 30 w In Cab Schematic Diagram Page 2 of 2...
Страница 169: ...169 MD RD MT Model 30 w In Cab Wiring Diagram Page 1 of 3...
Страница 170: ...170 MD RD MT Model 30 w In Cab Wiring Diagram Page 2 of 3...
Страница 171: ...171 MD RD MT Model 30 w In Cab Wiring Diagram Page 3 of 3...
Страница 172: ...172 MD RD MT Model 30 w In Cab CYCLE SENTRY Schematic Diagram Page 1 of 2...
Страница 173: ...173 MD RD MT Model 30 w In Cab CYCLE SENTRY Schematic Diagram Page 2 of 2...
Страница 174: ...174 MD RD MT Model 30 w In Cab CYCLE SENTRY Wiring Diagram Page 1 of 3...
Страница 175: ...175 MD RD MT Model 30 w In Cab CYCLE SENTRY Wiring Diagram Page 2 of 3...
Страница 176: ...176 MD RD MT Model 30 w In Cab CYCLE SENTRY Wiring Diagram Page 3 of 3...
Страница 177: ...177 MD RD MT Model 30 CYCLE SENTRY Wiring Diagram Page 1 of 3...
Страница 178: ...178 MD RD MT Model 30 CYCLE SENTRY Wiring Diagram Page 2 of 3...
Страница 179: ...179 MD RD MT Model 30 CYCLE SENTRY Wiring Diagram Page 3 of 3...
Страница 180: ...180 MD RD MT Model 50 w In Cab Schematic Diagram Page 1 of 2...
Страница 181: ...181 MD RD MT Model 50 w In Cab Schematic Diagram Page 2 of 2...
Страница 182: ...182 MD RD MT Model 50 w In Cab Wiring Diagram Page 1 of 3...
Страница 183: ...183 MD RD MT Model 50 w In Cab Wiring Diagram Page 2 of 3...
Страница 184: ...184 MD RD MT Model 50 w In Cab Wiring Diagram Page 3 of 3...
Страница 185: ...185 MD RD MT Model 50 w In Cab CYCLE SENTRY Schematic Diagram Page 1 of 2...
Страница 186: ...186 MD RD MT Model 50 w In Cab CYCLE SENTRY Schematic Diagram Page 2 of 2...
Страница 187: ...187 MD RD MT Model 50 w In Cab CYCLE SENTRY Wiring Diagram Page 1 of 3...
Страница 188: ...188 MD RD MT Model 50 w In Cab CYCLE SENTRY Wiring Diagram Page 2 of 3...
Страница 189: ...189 MD RD MT Model 50 w In Cab CYCLE SENTRY Wiring Diagram Page 3 of 3...
Страница 190: ...190 MD RD MT Model 50 CYCLE SENTRY Wiring Diagram Page 1 of 3...
Страница 191: ...191 MD RD MT Model 50 CYCLE SENTRY Wiring Diagram Page 2 of 3...
Страница 192: ...192 MD RD MT Model 50 CYCLE SENTRY Wiring Diagram Page 3 of 3...