Refrigeration Maintenance
107
6. By the time the discharge pressure decreases
approximately 50 psig (345 kPa), the ball in
the receiver tank sight glass should begin to
move and the liquid level should decline.
a. When discharge pressure stabilizes, the
ball and liquid level (liquid level in liquid
line sight glass) will rise.
b. If the ball will not begin to move or if the
liquid level (liquid level in liquid line sight
glass) will not decline, the unit most likely
has an overcharge of refrigerant. The
refrigerant level should be adjusted.
Adjusting the refrigerant level
1. With the condensing unit operating in High
Speed Cool and the Zone 2 evaporator in
Cool, use a gauge manifold set to pump
refrigerant from the receiver tank into an
approved container.
2. When the liquid level begins to decline in the
receiver tank sight glass (or liquid line sight
glass), close the hand valve on the gauge
manifold immediately. Allow the new liquid
level in the sight glass to stabilize (1 to 2
minutes).
3. If the liquid level is less than a full sight glass,
add refrigerant vapor to increase the liquid
level. With the unit operating in high speed
Cool, add refrigerant vapor through the
suction service valve until the ball is near the
top of the sight glass. Allow the level to
stabilize (1 to 2 minutes).
NOTE: R-404A refrigerant must be added as
a liquid. Maintain a discharge pressure of
275 psig (1900 kPa) or more and control
refrigerant flow so that suction pressure
increases approximately 20 psig (140 kPa).
4. Repeat the overcharge test.
Moisture Indicating Sight
Glasses
The receiver tank is equipped with a moisture
indicating sight glass. The outer edge of the sight
glass has a colored ring approximately 0.1 in.
(2.5 mm) thick. The color of the ring indicates the
moisture content of the refrigerant, but it may not
be completely reliable.
Green = Dry
Chartreuse = Caution
Yellow = Wet
A system has to run for at least 15 minutes to
change the color of the indicator ring after the
moisture content of the system has been changed.
For example, evacuating a system to remove the
moisture will not change the color of the indicator
ring until the system has been recharged and then
operated for at least 15 minutes.
1.
Floating Ball
2.
Colored Ring
Figure 57: Moisture Indicating Sight Glasses
1
2
sp2026
Содержание MD-MT
Страница 4: ...4...
Страница 10: ...Table of Contents 10...
Страница 22: ...Specifications 22...
Страница 41: ...Unit Description 41 Unit Photographs Figure 12 Roadside View Figure 13 Curbside View ARD024 ARD025...
Страница 43: ...Unit Description 43 Figure 15 Engine Side Door Open ARD041...
Страница 48: ...Unit Description 48...
Страница 128: ...Refrigeration Service Operations 128...
Страница 134: ...Hilliard Clutch Maintenance 134...
Страница 136: ...Structural Maintenance 136...
Страница 148: ...Refrigeration Diagnosis 148...
Страница 150: ...Remote Evaporator Specifications 150...
Страница 152: ...Remote Evaporator Maintenance Inspection Schedule 152...
Страница 156: ...Remote Evaporator Unit Description 156...
Страница 160: ...Remote Evaporator Structural Maintenance 160...
Страница 162: ...Remote Evaporator System Diagnosis 162...
Страница 166: ...Wiring and Schematic Diagrams Index 166...
Страница 167: ...167 MD RD MT Model 30 w In Cab Schematic Diagram Page 1 of 2...
Страница 168: ...168 MD RD MT Model 30 w In Cab Schematic Diagram Page 2 of 2...
Страница 169: ...169 MD RD MT Model 30 w In Cab Wiring Diagram Page 1 of 3...
Страница 170: ...170 MD RD MT Model 30 w In Cab Wiring Diagram Page 2 of 3...
Страница 171: ...171 MD RD MT Model 30 w In Cab Wiring Diagram Page 3 of 3...
Страница 172: ...172 MD RD MT Model 30 w In Cab CYCLE SENTRY Schematic Diagram Page 1 of 2...
Страница 173: ...173 MD RD MT Model 30 w In Cab CYCLE SENTRY Schematic Diagram Page 2 of 2...
Страница 174: ...174 MD RD MT Model 30 w In Cab CYCLE SENTRY Wiring Diagram Page 1 of 3...
Страница 175: ...175 MD RD MT Model 30 w In Cab CYCLE SENTRY Wiring Diagram Page 2 of 3...
Страница 176: ...176 MD RD MT Model 30 w In Cab CYCLE SENTRY Wiring Diagram Page 3 of 3...
Страница 177: ...177 MD RD MT Model 30 CYCLE SENTRY Wiring Diagram Page 1 of 3...
Страница 178: ...178 MD RD MT Model 30 CYCLE SENTRY Wiring Diagram Page 2 of 3...
Страница 179: ...179 MD RD MT Model 30 CYCLE SENTRY Wiring Diagram Page 3 of 3...
Страница 180: ...180 MD RD MT Model 50 w In Cab Schematic Diagram Page 1 of 2...
Страница 181: ...181 MD RD MT Model 50 w In Cab Schematic Diagram Page 2 of 2...
Страница 182: ...182 MD RD MT Model 50 w In Cab Wiring Diagram Page 1 of 3...
Страница 183: ...183 MD RD MT Model 50 w In Cab Wiring Diagram Page 2 of 3...
Страница 184: ...184 MD RD MT Model 50 w In Cab Wiring Diagram Page 3 of 3...
Страница 185: ...185 MD RD MT Model 50 w In Cab CYCLE SENTRY Schematic Diagram Page 1 of 2...
Страница 186: ...186 MD RD MT Model 50 w In Cab CYCLE SENTRY Schematic Diagram Page 2 of 2...
Страница 187: ...187 MD RD MT Model 50 w In Cab CYCLE SENTRY Wiring Diagram Page 1 of 3...
Страница 188: ...188 MD RD MT Model 50 w In Cab CYCLE SENTRY Wiring Diagram Page 2 of 3...
Страница 189: ...189 MD RD MT Model 50 w In Cab CYCLE SENTRY Wiring Diagram Page 3 of 3...
Страница 190: ...190 MD RD MT Model 50 CYCLE SENTRY Wiring Diagram Page 1 of 3...
Страница 191: ...191 MD RD MT Model 50 CYCLE SENTRY Wiring Diagram Page 2 of 3...
Страница 192: ...192 MD RD MT Model 50 CYCLE SENTRY Wiring Diagram Page 3 of 3...