![Thermo Dynamics CWL Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/thermo-dynamics/cwl/cwl_installation-operation-and-maintenance-manual_1104266007.webp)
5
HEATING CAPACITY 101,000 118,000 127,000
IBR NET RATING 88,000 103,000 110,000
INPUT 119,000 140,000 154,000
FIRING RATE .85 1.00 1.10
CHIMNEY SIZE 8 x 8 x 15 8 x 8 x 15 8 x 8 x 15
OVER FIRE PRESSURE W.C. 0-+.05 0-+.08 0-+.10
WATER CONTENT 15 GAL. 15 GAL. 15 GAL.
COIL CAPACITY 5 GAL. 5 GAL. 5 GAL.
A. JACKET HEIGHT* 29-1/2 29-1/2 29-1/2
B. JACKET WIDTH 21 21 21
C. COIL SUPPLY HEIGHT 22 22 22
D. SUPPLY HEIGHT (HYDRONIC) 27-1/2 27-1/2 27-1/2
E. BURNER HEIGHT 7-7/8 7-7/8 7-7/8
F. HYDRONIC RETURN HEIGHT 15-1/2 15-1/2 15-1/2
G. FLUE PIPE DIA. 5 5 5
H. WASHOUT (ALT. RETURN HEIGHT) 3-1/2 3-1/2 3-1/2
I. JACKET DEPTH (INCL. FLANGE) 22 22 22
DEPTH FRONT TO REAR W/BURNER 30-3/4 30-3/4 30-3/4
HYDRONIC SUPPLY 1-1/4 1-1/4 1-1/4
HYDRONIC RETURN SIZE 1-1/4 1-1/4 1-1/4
WASHOUT (ALT. RETURN) 1-1/4 (2) 1-1/4 (2) 1-1/4 (2)
AFUE RATING - W/DAMPER 86.0 84.9 84.1
AFUE RATING - W/O DAMPER 84.3 83.2 82.1
*Specifications apply to CWL-LE, NCWL and CWL-DV except when using REAR FLUE KIT, jacket height increases by
4-1/4 inches
Model Specifications CWL 85 CWL 100 CWL 110
“0” Clearance Sides and Back
Approved for combustible Floors
Figure 1 - Model Dimensions