background image

8

ENGLISH

END USER

END USER

RECYCLING AND DISPOSAL

The device is primarily composed of:

Material

Component

steel

structural work

PU (polyurethane)

insulation 

ABS (acrylonitrile-butadiene-styrene)

lining and covers

At the end of the device's useful life, these components must be separated and disposed of according to current regulations in 

the country of installation.

END USER INSTRUCTIONS

Refer to the GENERAL SAFETY INFORMATION and PRECAUTIONS section for safety-related information.

START-UP

The heater commissioning must be performed by Technical 

Assistance Centre personnel.

Under certain circumstances, such as after long periods of 

disuse, the user may need to re-start it without involving the 

Technical Assistance Centre. Before doing so, perform the fol-

lowing checks and operations.

- Check that the supply cocks in the domestic water cir-

cuit are all open

- Switch the electricity supply ON at the mains power 

switch and at control panel switch (if fitted).

TEMPORARY SHUTDOWN

To reduce to the environmental impact and save energy, in 

case of brief absences, week-ends, short trips, etc., and with 

external temperatures above 0°C, set the heater temperature 

control, where available, to the minimum value.

If the temperature to which the heater is exposed can 

fall below 0°C (frost hazard), perform the operations de-

scribed in paragraph "Preparing for extended periods of 

disuse".

PREPARING FOR EXTENDED PERIODS 

OF DISUSE

If the storage cylinder is not going to be used for an extended 

period of time, ask the manufacturer’s Technical Assistance 

Centre to make the system safe.

EXTERNAL MAINTENANCE

Clean the outside of the storage cylinder with a soft cloth 

damped in soapy water.

Do not use abrasive products, petrol or triethylene.

End user

RIELLO S.p.A.

Via Ing. Pilade Riello, 7

37045 - Legnago (VR)

www.thermital.it

The manufacturer strives to continuously improve all products. Appearance, 

dimensions, technical specifications, standard equipment and accessories are 

therefore liable to modification without notice.

Содержание TBPS 200 KOMPACT

Страница 1: ...TBPS 200 300 430 550 TBPS 750 1000 TBPS INSTALLATION OPERATION AND MAINTENANCE MANUAL ...

Страница 2: ...ng engineer b If water leaks from the storage cylinder turn off the water supply and contact T s Technical Assistance Centre or a qualified heating engineer immediately b If the product is not going to be used for an extended period of time contact the manufacturer s Technical As sistance Centre to have at least the following operations performed Close the shut off cocks for the domestic hot water...

Страница 3: ...insulation made of expanded polyurethane free from CFC chlorofluorocarbons a flange is provided for easy cleaning and maintenance of the anti corrosion magnesium anode IDENTIFICATION The T TBPS solar heaters can be identified by Data plate This lists the technical specifications and performance of the product BALLON SOLAIRE Modele Model Fabrication Code Année bar W l W kW l 1 BOLLITORE SOLARE Mode...

Страница 4: ...I 11300 1 38 1 53 1 67 1 89 2 13 2 33 W K Energy class B B B B B B PERFORMANCE RELATING TO INTEGRATION COIL Upper coil continuous efficiency ACS 10 45 C Vbu reference volume Upper coil delivery temperature 80 C T 20 C 16 1 23 31 4 31 4 50 50 kW 400 572 774 774 1240 1240 l h 70 C T 20 C 10 3 17 20 7 20 7 38 38 kW 247 425 505 505 930 930 l h 60 C T 20 C 6 5 11 15 5 15 5 25 25 kW 160 277 375 375 620 ...

Страница 5: ...d in 10 with heater pre heated to the indicated temperature considering an in crease of the domestic water temperature of 30 C between inlet and outlet according to EN 12897 Temperature of accumulation tank lower part 70 C 374 438 659 863 1190 1530 l 60 C 284 375 531 675 877 1110 l 50 C 205 310 390 485 762 790 l Integration coil probe point reference Vbu reference volume Solar coil probe reference...

Страница 6: ... leave one tooth open Apply the upper insulation 2 and the upper cover 5 use a spatula if the cover application on the protection plate proves difficult Close the interlocking flaps L completely which were previously left with an open tooth If disassembling is required proceed in reverse order 4 5 2 1 3 3 1 1 3 L 3 L b Wear suitable personal protective equipment and use suitable safety devices PLA...

Страница 7: ...1 208 207 75 75 mm B 243 253 329 348 289 289 mm C 403 393 427 443 428 421 mm D 598 693 684 788 799 834 mm E 738 903 824 1088 969 1006 mm F 878 1113 964 1328 1144 1337 mm G 953 1233 1064 1428 1234 1426 mm H 1029 1323 1174 1538 1321 1506 mm I 1098 1438 1289 1653 1444 1637 mm L 1170 1670 1440 1784 1707 2032 mm M 1338 1838 1644 1988 1846 2171 mm N Ø 604 Ø 604 Ø 755 Ø 755 Ø 1000 Ø 1000 mm O M8 threaded...

Страница 8: ... mains power switch and at control panel switch if fitted TEMPORARY SHUTDOWN To reduce to the environmental impact and save energy in case of brief absences week ends short trips etc and with external temperatures above 0 C set the heater temperature control where available to the minimum value b If the temperature to which the heater is exposed can fall below 0 C frost hazard perform the operatio...

Отзывы: