GENERAL INFORMATION

RANGE

MODEL

CODE

TBPS 200

20117887

TBPS 300

20117888

TBPS 430

20117889

TBPS 550

20117890

TBPS 750

20117891

TBPS 1000

20117892

ACCESSORIES

For a complete list of accessories and details of their compati-

bility, refer to the Catalogue.

Dear heating engineer,

We would like to congratulate you on having recommended a 

T

 solar storage cylinder unit: a modern product 

that's capable of ensuring a high degree of reliability, efficien-

cy, quality and safety.

While your technical skills and knowledge will certainly be 

more than sufficient, this booklet contains all the information 

that we have deemed necessary for the device's correct and 

easy installation.

Thank you again, and keep up the good work,

Thermital

CONFORMITY

The 

T

 solar heaters comply with DIN 4753-3 and 

UNI EN 12897.

CONTENTS

The following symbols are used in this manual:

CAUTION! =

 Identifies actions that require caution and 

adequate preparation.

STOP! =

 Identifies actions that you MUST NOT do.

GENERAL SAFETY INFORMATION

Check that the product is complete, undamaged and as 

ordered as soon as you receive it. Report any discrepan-

cies or damage to the 

T

 dealer who sold it.

This product must be installed by a legally qualified heat-

ing engineer. On completion of the installation, the install-

er must issue the owner with a declaration of conformity 

confirming that the installation has been completed to 

the highest standards in compliance with the instructions 

provided by 

T

 in this instruction manual, and 

that it conforms to all applicable laws and standards.

This product must only be used for the purpose for which 

it is designed and made, as specified by 

T

T

 declines all responsibility, contractual or 

other, for damage to property or injury to persons or ani-

mals caused by improper installation, adjustment, main-

tenance or use.

The product must be serviced at least once a year. Servic-

ing must be arranged in advance with the 

T

 

Technical Assistance Centre.

All servicing and repairs must be performed by a quali-

fied heating engineer.

If water leaks from the storage cylinder, turn off the water 

supply and contact 

T

’s Technical Assistance 

Centre or a qualified heating engineer immediately.

If the product is not going to be used for an extended 

period of time, contact the manufacturer’s Technical As-

sistance Centre to have at least the following operations 

performed:

- Close the shut-off cocks for the domestic hot water cir-

cuit

- Shut down the boiler connected to the storage cylinder 

as instructed in its own manual

- Switch the storage cylinder OFF at the control panel (if 

fitted) and at the mains power switch

- Drain the central heating circuit and domestic hot water 

circuit if there is any risk of freezing.

This instruction manual is an integral part of the prod-

uct. It must be kept safe and must ALWAYS accompany 

the product, even if it is sold to another owner or trans-

ferred to another user or to another installation. If you 

lose this manual, order a replacement immediately. Keep 

the product purchase documents to be presented to the 

T

 authorised Technical Assistance Centre to 

request a service call under warranty.

Size the solar expansion tank so as to ensure complete 

absorption of the expansion of the fluid contained within 

the system, with reference to the prevailing regulations 

on the matter. In particular, consider fluid characteris-

tics, considerable fluctuation of service temperature and 

vapour that might be generated during solar collector 

stagnation stage. Proper size of expansion tank ensures 

setting off of all volume changes of the heat transfer fluid, 

avoiding excessive pressure increase. Limited pressure 

changes avoid reaching safety valve opening pressure 

and the consequent fluid drainage.

This manual, Code

- Rev.

comprises

pages.

ENGLISH

General information

GENERAL INFORMATION                                           2

General Safety Information. . . . . . . . . . . . . . . . . . . . . . . . . . 2

Precautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Description of the appliance  . . . . . . . . . . . . . . . . . . . . . . . . 3

Identification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

System layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Technical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

INSTALLATION                                                             6

Unpacking the product  . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Assembly of the insulation and the lining   . . . . . . . . . . . . . . .  

(models 750 - 1000). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Place of installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Installation in older systems and systems requiring 

modernisation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Water quality requirements. . . . . . . . . . . . . . . . . . . . . . . . . . 6

Water connections  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Recycling and disposal  . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

END USER                                                                   8

Start-up. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Temporary shutdown  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Preparing for extended periods of disuse  . . . . . . . . . . . . . . 8

External maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Содержание TBPS 200 KOMPACT

Страница 1: ...TBPS 200 300 430 550 TBPS 750 1000 TBPS INSTALLATION OPERATION AND MAINTENANCE MANUAL ...

Страница 2: ...ng engineer b If water leaks from the storage cylinder turn off the water supply and contact T s Technical Assistance Centre or a qualified heating engineer immediately b If the product is not going to be used for an extended period of time contact the manufacturer s Technical As sistance Centre to have at least the following operations performed Close the shut off cocks for the domestic hot water...

Страница 3: ...insulation made of expanded polyurethane free from CFC chlorofluorocarbons a flange is provided for easy cleaning and maintenance of the anti corrosion magnesium anode IDENTIFICATION The T TBPS solar heaters can be identified by Data plate This lists the technical specifications and performance of the product BALLON SOLAIRE Modele Model Fabrication Code Année bar W l W kW l 1 BOLLITORE SOLARE Mode...

Страница 4: ...I 11300 1 38 1 53 1 67 1 89 2 13 2 33 W K Energy class B B B B B B PERFORMANCE RELATING TO INTEGRATION COIL Upper coil continuous efficiency ACS 10 45 C Vbu reference volume Upper coil delivery temperature 80 C T 20 C 16 1 23 31 4 31 4 50 50 kW 400 572 774 774 1240 1240 l h 70 C T 20 C 10 3 17 20 7 20 7 38 38 kW 247 425 505 505 930 930 l h 60 C T 20 C 6 5 11 15 5 15 5 25 25 kW 160 277 375 375 620 ...

Страница 5: ...d in 10 with heater pre heated to the indicated temperature considering an in crease of the domestic water temperature of 30 C between inlet and outlet according to EN 12897 Temperature of accumulation tank lower part 70 C 374 438 659 863 1190 1530 l 60 C 284 375 531 675 877 1110 l 50 C 205 310 390 485 762 790 l Integration coil probe point reference Vbu reference volume Solar coil probe reference...

Страница 6: ... leave one tooth open Apply the upper insulation 2 and the upper cover 5 use a spatula if the cover application on the protection plate proves difficult Close the interlocking flaps L completely which were previously left with an open tooth If disassembling is required proceed in reverse order 4 5 2 1 3 3 1 1 3 L 3 L b Wear suitable personal protective equipment and use suitable safety devices PLA...

Страница 7: ...1 208 207 75 75 mm B 243 253 329 348 289 289 mm C 403 393 427 443 428 421 mm D 598 693 684 788 799 834 mm E 738 903 824 1088 969 1006 mm F 878 1113 964 1328 1144 1337 mm G 953 1233 1064 1428 1234 1426 mm H 1029 1323 1174 1538 1321 1506 mm I 1098 1438 1289 1653 1444 1637 mm L 1170 1670 1440 1784 1707 2032 mm M 1338 1838 1644 1988 1846 2171 mm N Ø 604 Ø 604 Ø 755 Ø 755 Ø 1000 Ø 1000 mm O M8 threaded...

Страница 8: ... mains power switch and at control panel switch if fitted TEMPORARY SHUTDOWN To reduce to the environmental impact and save energy in case of brief absences week ends short trips etc and with external temperatures above 0 C set the heater temperature control where available to the minimum value b If the temperature to which the heater is exposed can fall below 0 C frost hazard perform the operatio...