List of user parameters
Menu
Par.
No.
Description
Range
Default
setting
UM
Main menu
0000
013
Quick adjustment of direct Zone/Zone 1 heating setpoint in 0
and 3 heating modes.
By connecting the zone control accessory, this parameter can
be used to quickly change direct Zone/Zone 1 setpoint. This
parameter simultaneously modifies the value of Par. 2103.
See Par. 2103
See Par.
2103
°C
0000
023
Quick adjustment of Zone 2 heating setpoint in 0 and 3 heating
modes.
By connecting the zone control accessory, this parameter can
be used to quickly change Zone 2 setpoint. This parameter
simultaneously modifies the value of Par. 2203.
See Par. 2203
See Par.
2203
°C
0000
033
Quick adjustment of Zone 3 heating setpoint in 0 and 3 heating
modes.
By connecting the zone control accessory, this parameter can
be used to quickly change Zone 3 setpoint. This parameter
simultaneously modifies the value of Par. 2303.
See Par. 2303
See Par.
2303
°C
0000
047
Quick adjustment of DHW setpoint with heater
This parameter is only visible with Par. 2035 = 1
See Par. 2047
°C
0000
048
Quick adjustment of DHW setpoint with instant production
This parameter is only visible with Par. 2035 = 10
See Par. 2048
°C
0000
201
Stops the venting function
0 = No action
1 = Stop venting
Visible only when de-aeration is in operation
0…1
0
Info menu
1000
1001 CH flow temperature
°C
1000
1002 Domestic hot water temperature
°C
1000
1003 Domestic cold water temperature
This parameter is only visible with Par. 2035 = 10
°C
1000
1004 Outdoor temperature
°C
1000
1007 Return temperature
°C
1000
1033 System pressure
bar
1000
1056 Total hours of operation in heating mode
h x 10
1000
1057 Total hours of operation in domestic mode
h x 10
1000
1058 Total hours of operation
h x 10
1000
1062 Function not implemented
1000
1063 Input signal 0-10V
V
1000
1090
Counts down the days to the next service (if it’s past, a nega-
tive value is shown)
If the value is < 15 the service icon flashes
Days
1000
1101 Direct Zone/Zone 1 delivery temperature
°C
1000
1102 Direct Zone/Zone 1 ambient temperature
°C
1000
1112 Zone 1 heating setpoint
°C
1000
1201 Zone 2 delivery temperature
°C
1000
1202 Zone 2 ambient temperature
°C
1000
1212 Zone 2 heating setpoint
°C
1000
1301 Zone 3 delivery temperature
°C
1000
1302 Zone 3 ambient temperature
°C
1000
1312 Zone 3 heating setpoint
°C
Heating general settings
2000
2021 Number of days to next service
365
Days
2000
2022
Service reminder
This function reminds the user of the need to carry out a pro-
grammed service on the boiler, after the number of days set in
Par. 2021
0 = Deactivates the function
1 = Activates the function
2 = Resets the countdown of days to next service to zero
0…2
0
2000
2078
Set service hours countdown
0= Burner’s hours of operation
1 = Boiler’s hours of operation
0…1
0