Remove knock-out holes to the left, right
or on top.
5.3
Alternative 1 (left)
For connection in to the left hand side "knockout holes".
1, Press the quick couplings (delivered with the heat pump) on to the pipes according to the picture . Make sure the coupling reach the
32 mm mark.
32 mm
32 mm
2, Insulate before mounting the pipes.
3, Install the insulated pipes from the inside of the heat pump and out. Pay attention to which one of the pipes are brine in and brine
out. (See picture below.)
4, Press the pipes on to the connections in the heat pump. (The pipe connections are located behind the electrical cabinet in the heat
pump, remove the metal plate.)Isolate with insulation tape so that it is partially seated against the plate.
IN
OUT
5, Fit the rubber sleeves into the knockout holes.
Installation Guide
Diplomat Inverter Mini
Thermia AB
INQG0102
15