6.4
Power supply 400V version
If the heat pump is connected to ground fault switch RCDs, it should be connected to a separate type B.
L1 L2
N
L3
L1
PE
PE
L2
L3
N
1
2
3
4
OK
12mm
▪
L1, L2: Internal immersion heater, control and circulation pump
▪
L3: Inverter, compressor
Fuse size
400V, ~3N, 50 Hz
FUSE
C-CURVE
6kW
13A 13A 13A 16A
1,5-7kW
+
2kW 4kW
Minimum recommended fuse size.
Maximum operating current of compressor: 12 A at 230V (nominal)
The internal immersion heater limit in the heat pump control and may be permitted in different steps with / without compressor.-
▪
Step 1: 2kW
▪
Step 2: 4kW
▪
Step 3: 6kW
Installation Guide
Diplomat Inverter Mini
Thermia AB
INQG0102
19