background image

Remove protective cover, disconnect the wires, unscrew and remove removable flange from the 

џ

housing;

Replace magnesium anode, clean TEH from scale if required and remove sediment;

џ

Assemble, fill EWH with water and switch on power supply.

џ

During the EWH technical maintenance by a specialized company, a warranty certificate shall include 

a relevant 

note with the seal of the company

, carrying out technical maintenance. During the 

magnesium anode replacement by the user, this EWH user manual shall be accompanied by the 

sales ticket for magnesium anode purchase.

Safety precautions

Electrical safety and anti-corrosion protection of EWH shall be guaranteed only in case of the 

efficient earthing, executed in accordance with the existing installation regulations.

During the EWH installation and operation it is not allowed to:

Connect electrical power in case EWH is not filled with water.

џ

Remove protective cover with power on.

џ

Use EWH without earthing or use water supply pipes as earthing.

џ

Install EWH into the water supply line with pressure over 0,8 MPa. Provided that pressure in 

џ

the water supply line exceeds 0,8 MPa, cold water inlet pipe to EWH, upstream the safety 

valve (along water path) shall be equipped with the relevant pressure reducer valve (not 

included into the EWH scope of supply) to reduce cold water pressure to normal value. 

Installation of the pressure reducer valve between EWH and safety valve is prohibited.

Connect EWH to water supply line without a safety valve.

џ

Drain water from EWH with power on.

џ

Use spare parts not recommended by the manufacturer.

џ

Use water from EWH for cooking.

џ

Use  water  containing  mechanical  additives  (sand,  small  stones),  resulting  in  EWH  and 

џ

safety valve malfunction.

Alter design and setting dimension of EWH brackets.

џ

Avoid water freezing in the device to exclude failure, that is not covered by the warranty.

EWH is not intended for operation by persons with limited physical, sensor or mental capacities, as 

well as by persons not trained to use EWH, except for the cases of operation under supervision or in 

accordance with the guidelines of the persons responsible for EWH safety. Children are allowed to 

use EWH only under the supervision of persons responsible for safe operation. During the EWH 

operation it is necessary to inspect the device for correct operation frequently (absence of leaks, 

burning odor, sparks in wiring etc.). In case of long-terms breaks in the water heater operation and/or 

faults of the water supply line operation, it is necessary to disconnect EWH from the power network 

and shut off cold water inlet valve.

Always mind the risk of scalding with hot water and electrical shock.

14

EN

Possible failures and remedies

In case of the device failure it is necessary to disconnect it from the electrical network and shut off 

water supply.

EWH is connected 

to electric network but 

is not heating water. 

Failure of control lamp 

illumination.

No voltage in the electric 

network

Contact electric network 

maintenance company

Frequent activation 

of thermal switch

Preset temperature is close 

to maximum

Turn thermostat control unit 

to temperature reduction side (–)

Thermostat tube is covered 

with scale

Take out removable flange from 

EWH and clean the pipe 

from scale

Increased heating time

THE is covered by a scale 

layer

Remove the flange and clean THE 

from scale

Reduced voltage in the 

electric network

Contact electric network 

maintenance company

Reduced hot water 

head from EWH Same 

cold water head

Remove and wash valve with water

Clogging of the safety valve 

inlet hole 

Failure 

Remedy

Possible cause 

Contact service center

Power cable is damaged

Protection tripping device 

activated (if available)

Push protection tripping device 

reset button. Check voltage

Disconnect EWH from electric 

network, remove protective cover, 

press thermal switch button 

(

Fig. 4

), install protective cover 

and switch on power supply

Thermal switch is activated 

or not switched on

The abovementioned failures are not EWH defects and shall be recovered by the user or by means of 

a specialized organization at it own expense.

In case of failure to recover the faults using the abovementioned recommendations or on case of 

detection some other faults, it is necessary to contact the service center, specified in the user manual.

15

EN

Содержание 526142

Страница 1: ...Electric storage water heaters Scaldacqua elettrico User manual Manuale d uso...

Страница 2: ......

Страница 3: ...3 Fig 1 1 2 15 12 16 13 9 7 3 14 8 11 4 5 10 6 17 18 1 2 15 12 16 13 9 7 3 14 8 11 4 5 10 6 20 19 21 Fig 2 17 18...

Страница 4: ...Fig 4 4 2 15 12 13 9 3 7 8 11 1 16 4 17 10 14 Fig 3 5 6 Push Premere 18...

Страница 5: ...e almeno Un rubinetto di intercettazione Una valvola di ritegno Un dispositivo di controllo della valvola di ritegno Una valvola di sicurezza Un dispositivo di interruzione di carico idraulico I sudde...

Страница 6: ...HYDRAULIC SAFETYGROUP must include at least An intercept faucet Acheck valve Acheck valve control device Asafety valve Ahydraulic load breaker The aforementioned accessories are necessary for the purp...

Страница 7: ...t Termostato Magnesium anode Anodo di magnesio Thermostat control unit Manopola di termostato Control indicator lamp Lampadina spia di segnalazione Temperature indicator Indicatore di temperatura Hot...

Страница 8: ...rone Yellow green Verde giallo Control indicator lamp Lampadina spia di segnalazione THE 1 2 kW 230 V for EWH with volume from 30 to 80 liters 1 5 kW 230 V for EWH with volume from 100 to 150 liters R...

Страница 9: ...water supply to the amenity and industrial facilities having cold water line and heat transfer medium line for ER models 05022 480 08022 480 10022 480 15022 480 05022 481 08022 481 10022 481 15022 481...

Страница 10: ...om part of the housing The serial number consist of thirteen digits The third and the fourth digit of the serial number is the year of production the fifth and the sixth is the month of production the...

Страница 11: ...unctions of the safety valve releasing overpressure in the tank at high water heating Protective cover of the device is equipped with the control indicator lamp 11 reflects EWH operation in the autono...

Страница 12: ...valve into the sewage system to remove lime deposits and check operability of the valve Connection to the water supply line shall be carried out in accordance with Fig 1 3 using copper plastic pipes...

Страница 13: ...um anode shall be replaced more frequently Scale buildup on the TEH may result in its failure that is not covered by the warranty thereby its replacement is not included into the obligations of the ma...

Страница 14: ...pressure reducer valve not included into the EWH scope of supply to reduce cold water pressure to normal value Installation of the pressure reducer valve between EWH and safety valve is prohibited Co...

Страница 15: ...twork Contact electric network maintenance company Reduced hot water head from EWH Same cold water head Remove and wash valve with water Clogging of the safety valve inlet hole Failure Remedy Possible...

Страница 16: ...wer cable shall not be considered as EWH fault and does not result in EWH replacement The buyer or an installation company carrying out connection shall be responsible for compliance with the installa...

Страница 17: ...epaired compo nents shall be expired as of the date of the EWH warranty expiry Disposal Under condition of compliance with the installation operation and technical maintenance regulations of EWH and w...

Страница 18: ...480 10022 480 15022 480 05022 481 08022 481 10022 481 15022 481 sono destinati a riscaldamento indiretto dell acqua dal calore prodotto dalla caldaia a gas o a combustibile liquido La resistenza elet...

Страница 19: ...iportato sulla targhetta identificativa posta nella parte bassa del corpo dello scaldacqua Il numero di matricola dello scaldacqua comprende tredici cifre La terza a la quarta cifra codificano l anno...

Страница 20: ...di pressione nella tubazione stessa o in caso di aumento della pressione nel serbatoio durante il riscaldamento dell acqua ed anche funzione di protezione evitando sovrappressioni nel serbatoio duran...

Страница 21: ...acqua Questo tubo di scarico aperto deve essere previsto in pendenza continua verso il basso ed essere utilizzato in ambiente che non permetta congelamento Si consiglia di raccordare allo scarico un t...

Страница 22: ...AVVERTENZA Prima dell accensione dell apparecchio occorre verificare che lo scaldacqua sia completamente riempito con l acqua Lo scaldacqua deve essere provvisto di messa a terra per un funzionamento...

Страница 23: ...orpo dello scaldacqua Cambiare l anodo di magnesio provvedere alla pulizia ed asportazione del calcare dalla resistenza elettrica se necessario Rimontare lo scaldacqua riempirlo d acqua e ripristinare...

Страница 24: ...l cablaggio etc In caso della sospensione prolungata dell uso dello scaldacqua interruzione del funzionamento dell alimentazione idrica occorre scollegare lo scaldacqua dalla rete elettrica e chiudere...

Страница 25: ...icurezza non riarmato In caso di rilevazione dell anomalie di funzionamento occorre disinserire l apparecchio dalla rete elettrica e bloccare l entrata dell acqua Tutte le anomalie sopraindicate non p...

Страница 26: ...resentano i difetti attribuiti allo scaldacqua e non vengono reintegrati in caso di sostituzione dello scaldacqua stesso La responsabilit dell osservanza delle indicazioni per installazione e collegam...

Страница 27: ...ua utilizzata agli standard vigenti il produttore applica vita utile pari a 7 anni dalla data dell acquisto dello scaldacqua Tutte le parti componenti lo scaldacqua sono prodotte con materiali che con...

Страница 28: ...ervice center indicated by dealer Centro di assistenza indicato dal venditore Warranty certificates Tagliando di garanzia Note of sale Contrassegno di vendita Stamp of dealer Timbro del venditore Cust...

Страница 29: ...ealer Riservato al venditore 1 Model Modello 2 2 Serial No Numero di matricola 3 Date of sale Data di vendita 4 Dealer Venditore 5 Stamp of dealer Timbro del venditore 6 Filled in by dealer Riservato...

Страница 30: ...zione 2 Issue date Data di consegna 3 Defect Difetto 4 Executed work Lavori eseguiti 6 Stamp of service center Timbro del centro di assistenza 5 Specialist name Tecnico 7 Filled in by service center R...

Страница 31: ......

Страница 32: ......

Отзывы: