background image

Steamhead rough-in fitting to be 
installed flush with finished wall

A

B

Parts provided 
by installer

Aromatherapy 
Fill Channels

Place silicone 
around groove

Materials needed:

o

   Steamhead

o

   Steamhead Rough-In 

 

Housing 1/2" Copper Tubing  

 

(For PRO-650, PRO-850 -  

 

3/4" drop elbow, 3/4"  

 

Copper Tubing 50' max.  

 

(2) 3/4" to 1/2" adapters)

Silicone

Other materials as required

Tools needed:

1" deep socket 

 

and ratchet

o  

2 1/2" Masonry/tile/stone 

 

Hole Saw

Steamhead

(Contemporary style shown here)

Installation instructions

Silicone

2

 

Tools and Materials

Parts enclosed

Steamhead Installation Instructions

Steamhead Location

Upon final installation mount steamhead 
with   facing up to allow aromatherapy 
well to dispense steam.

DO NOT install the steamhead near the seating area or 
the user.

DO NOT forget to install the steamhead rough-in fitting!
INSTALL steamhead as far as possible from the in-
shower controller. NEVER install the steamhead under 
controller 

 

 Install the steamhead 12" from the floor or bathtub 
rim and 6" from any corner.

 

 Steamhead is to be mounted as far as possible 
from typical bathing position (seated or standing) 
and installed as far from the in-shower controller as 
possible.

 

i. For retrofit to existing finish wall: 

 

Drill a 2-1/2" diameter hole in the shower wall or  

 

wall above bathtub rim for the steam outlet rough- 

 

in fitting and install to be flush with the finished  

 

wall. (plumbing must be done from backside of  

 

finshed space)

 

ii. For new framing: 

Mount and install rough-in  

 

fitting to be flush with finished wall. 

Connect a 1/2" NPT brass pipe or copper tubing to 
the steam outlet union (not included) on the generator 
running the pipe to the steam head location in the wall 
to connect with the steamhead rough-in. For PRO-650 
and PRO-850 run 3/4" copper steam line. It is very 
important that the pipe is firmly secured to the wall, so 
that when the steamhead is installed it doesn’t push the 
rough-in fitting back into the wall. Install a 1/2” drop-
ear elbow on the end of the 1/2” pipe or tubing for the 
rough-in fitting. For all the connections, use solder for 
copper joints and Teflon tape for pipe fittings and do not 
over tighten fittings. DO NOT USE PVC CEMENT. 

For detail installation instructions of the
steamhead please see Installation section
in thermasol.com/customersupport

A

B

3

 

Steamhead Location

O-Rings

10

THERMASOL.COM  

I

  800.776.0711

Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details. 

81193_NC 4/16

Содержание MTC Series

Страница 1: ...allation Manual For Tutorials and Troubleshooting visit www thermasol com solutions MTT NTS XX Tradtional MTM NTS XX Modern MTMR NTS XX Modern Recessed MTC NTS XX Contemporary MTR NTS XX Regency OVER 55 YEARS OF STEAM SHOWER INNOVATION ...

Страница 2: ...ation Manual For Tutorials and Troubleshooting visit www thermasol com solutions From top L to R MTC XX Contemporary MTT XX Tradtional MTM XX Modern MTR XX Regency MTMR XX Modern Recessed OVER 55 YEARS OF STEAM SHOWER INNOVATION ...

Страница 3: ...ER REGARDING THE SAFE USE OF YOUR FLOORING IN A STEAM APPLICATION SLIPPING AND FALLING INTO THE STEAMHEAD ITSELF OR INTO THE STREAM OF STEAM EMITTING FROM THE STEAMHEAD WILL CAUSE SERIOUS BURNS OR PHYSICAL INJURY IF YOU ARE FEELING UNCOMFORTABLE DIZZY FAINT OR STARTING TO FALL ASLEEP IMMEDIATELY EXIT THE STEAM ROOM DO NOT USE STEAM ROOM IF YOU ARE UNDER THE AGE OF 16 UNLESS SUPERVISED BY AN ADULT ...

Страница 4: ...ller Contemporary style shown here Materials needed o MicroTouch control o CAN bus cable included with generator o Silicone o Other materials as required Tools needed o 1 2 drill for surface mount o Follow pre installation instruction on page 5 for recessed mount controls o Drill motor o Other tools as required Mud Ring RIK TPMR 1 for MTMR XX installation only Install recessed control mud ring pro...

Страница 5: ...nd steam line or route it in a manner so that the hot steam line could melt the cable Any damage to the control cable will result in the control not working properly Carefully connect the data cable to the generator and control BEFORE turning power on to the generator ON Turn Clockwise OFF Turn Counter Clockwise Do not staple strain or damage data cable Align pins to receptacle visually before tig...

Страница 6: ...ce sits flush to wall Connect cable so it is not lost in wall Test fit for flushness Step 3 IMPORTANT Fully test the control system prior to silicone Once desired fit is achieved coat back of con trol face with supplied silicone Firmly press to wall surface and wipe excess silicone from around control Tape into LEVEL position and let dry for 24 hours before using steam bath Data Cable Step 1 Coat ...

Страница 7: ...ymbols which are located immediately to the left and to the right of the power icon An arc array of lit squares will appear from left to right Increase the temperature by touching symbol until desired temperature is displayed by the blue LED lights running clockwise to indicate an increase in temperature Reduce the temperature by touching symbol and the array of LEDs will begin to turn off Power F...

Страница 8: ...ble Shooting Tutorials and Error Codes Visit www thermasol com solutions Click on Troubleshoot then click on MicroTouch Control Error Codes Read warnings on page 3 For illustrative purposes only Consult with qualified professional for steam room construction details PN 81193_NC 4 16 ...

Страница 9: ...llation Installation Manual For Tutorials and Troubleshooting visit www thermasol com solutions From top NTST XX Traditional NTSM XX Modern NTSC XX Contemporary NTSR XX Regency OVER 55 YEARS OF STEAM SHOWER INNOVATION ...

Страница 10: ...in shower controller as possible i For retrofit to existing finish wall Drill a 2 1 2 diameter hole in the shower wall or wall above bathtub rim for the steam outlet rough in fitting and install to be flush with the finished wall plumbing must be done from backside of finshed space ii For new framing Mount and install rough in fitting to be flush with finished wall Connect a 1 2 NPT brass pipe or ...

Страница 11: ...ad of waterproof silicone around the steamhead using the machined groove located on the back of the steamhead as a guide Be sure there isn t any debris within the housing and that the two O rings are in place on the steamhead Press the steamhead into the housing until the steamhead is tight against the finished wall You may need to wipe away any excess silicone Make sure aromatherapy fill channels...

Страница 12: ...1958 STEAM WAY ROUND ROCK TX 78665 PHONE 800 776 0711 SUPPORT THERMASOL COM WWW THERMASOL COM WWW THERMASOL COM SOLUTIONS 81193_NC 4 16 ...