Steamhead rough-in fitting to be
installed flush with finished wall
A
B
Parts provided
by installer
Aromatherapy
Fill Channels
Place silicone
around groove
Materials needed:
o
Steamhead
o
Steamhead Rough-In
Housing 1/2" Copper Tubing
(For PRO-650, PRO-850 -
3/4" drop elbow, 3/4"
Copper Tubing 50' max.
(2) 3/4" to 1/2" adapters)
o
Silicone
o
Other materials as required
Tools needed:
o
1" deep socket
and ratchet
o
2 1/2" Masonry/tile/stone
Hole Saw
Steamhead
(Contemporary style shown here)
Installation instructions
Silicone
2
Tools and Materials
Parts enclosed
Steamhead Installation Instructions
Steamhead Location
Upon final installation mount steamhead
with facing up to allow aromatherapy
well to dispense steam.
DO NOT install the steamhead near the seating area or
the user.
DO NOT forget to install the steamhead rough-in fitting!
INSTALL steamhead as far as possible from the in-
shower controller. NEVER install the steamhead under
controller
Install the steamhead 12" from the floor or bathtub
rim and 6" from any corner.
Steamhead is to be mounted as far as possible
from typical bathing position (seated or standing)
and installed as far from the in-shower controller as
possible.
i. For retrofit to existing finish wall:
Drill a 2-1/2" diameter hole in the shower wall or
wall above bathtub rim for the steam outlet rough-
in fitting and install to be flush with the finished
wall. (plumbing must be done from backside of
finshed space)
ii. For new framing:
Mount and install rough-in
fitting to be flush with finished wall.
Connect a 1/2" NPT brass pipe or copper tubing to
the steam outlet union (not included) on the generator
running the pipe to the steam head location in the wall
to connect with the steamhead rough-in. For PRO-650
and PRO-850 run 3/4" copper steam line. It is very
important that the pipe is firmly secured to the wall, so
that when the steamhead is installed it doesn’t push the
rough-in fitting back into the wall. Install a 1/2” drop-
ear elbow on the end of the 1/2” pipe or tubing for the
rough-in fitting. For all the connections, use solder for
copper joints and Teflon tape for pipe fittings and do not
over tighten fittings. DO NOT USE PVC CEMENT.
For detail installation instructions of the
steamhead please see Installation section
in thermasol.com/customersupport
A
B
3
Steamhead Location
O-Rings
10
THERMASOL.COM
I
800.776.0711
Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details.
81193_NC 4/16