GUARANTEE 

This Sauna  heater is guaranteed 

for  one  year  from  date  of purchase,  and  includes all 

heater  parts  such  as  heating  elements,  controls, 

contactors,  etc. 

This  guarantee  covers  faults  in  manufacture  and 

material  only,  and  includes  the  exchange  of  new 

parts  supplied  by  the  manufacturer  or  manufac­

turer's agent, after the faulty part has been returned 

to  same.  The replacement of parts under warranty 

does  not  extend  the  warranty  period  beyond  the 

original one year. 

The  guarantee  does not cover  defects  caused by 

normal  wear  and tear,  defects  caused  by improper 

installation,  poor  maintenance,  or  failure  to  follow 

the manufacturer's instructions for installation, use 

and care, or alterations made to the Sauna product. 

This  guarantee  is  void  if  the  heater  is  used 

improperly, pool or spa water should not be poured 

over the Sauna stones,  as chemicals are harmful to 

the heater;  the  Sauna  room  must  be  heated  for  at 

SAUNA HEATER        

MODEL NUMBER 

DATE OF PURCHASE 

ORIGINAL OWNER 

ADDRESS 

PURCHASED FROM 

ELECTRICAL CONTRACTOR 

MUST SIGN HERE 

DA TE  OF  ELECTRICAL 

WIRING  &  HOOKUP 

THERMASOL

800-776-0711

least  30  minutes  before  water  is  poured  over  the 

stones;  only one or two dippers full of water should 

be  poured  over  the  hot  stones  at  one  time.  This 

guarantee will be void if a shower has been installed 

in the Sauna room. 

This guarantee does not cover delivery costs of the 

faulty  part  or  costs  of  the  person  carrying  out  the 

repair in the field. If the Sauna heater is returned to the 

manufacturer  or  manufacturer's  agent  in  Portland, 

Oregon, within five years after date of purchase, the 

agent will provide free labor for repair, but will charge 

for  parts  if date of purchase is past one year. 

This guarantee will be void if installation and wiring 

is  not  carried  out  by  a  certified  electrician  or 

authorized and qualified service representative, who 

must sign  below. 

This guarantee will  be  void if  is  not filled  out  and 

returned within 1 5 days of purchase,  and it applies 

only to original installation of product and to original 

purchaser. 

11

81205_NC

Содержание F-2

Страница 1: ...e and guarantee IMPORTANT This manual must be left with owner manager or operator of Sauna after it is used by electrician MODEL HCT105 1 HCT120 1 HCT144 1 CONTROLS F 2T F 2 co M To UL STD 875 c us CERTIFIED TO CAN CSA STD 3159549 E60335 2 53 05 MODEL HCT105 3 HCT120 3 HCT144 3 CONTACTORS FX404 FX503 1 81205_NC ...

Страница 2: ...2 81205_NC ...

Страница 3: ...e 3 MODEL INPUT MIN HEIGHT FT HCT105 1 10 0 6 5 HCT105 3 HCT120 1 12 5 6 5 HCT120 3 HCT144 1 15 0 6 5 HCT144 3 Table 1 20 1 r w 1 r _ _J W t I a o ez o cor a FLOOR AREA MIN MAX SO FT SQ FT 60 94 78 114 97 146 HEATER MIN CLEARANCE FROM WALL AND FENCE 5 MIN 110 kW 6 MIN 112 5 15 kW 21 2 I WOOD FENCE Figure 4 HEATER MIN CLEARANCE FROM BENCHES 0 0 _ Figure 4A V SAUNA ROOM MIN SPACING FROM ADJACENT SUR...

Страница 4: ...es Use copper wire from load center to wall mounted contactor Supply cable must have 5 wires including insulated neutral plus separate ground Use 90 C copper wire from contactor to control and from control to room light Also use 90 C copper wire from contactor to Sauna heater within seal tight flex conduit and connect to junction box at heater with 90 connector Connect to the noted terminals and c...

Страница 5: ... wire from breaker to wall mounted contactor Supply cable must have 4 wires including insulated neutral plus separate ground Use 90 C copper wire from contactor to control and from control toroom light Also use 90 C copper wire from contactor to Sauna heater within seal tight flex conduit and connect tojunction box under heater at back with 90 connector Connect to the noted terminals and connect g...

Страница 6: ...81205_NC ...

Страница 7: ...per breaker to contactor contactor to heater HCT105 3 9 800 27 3 208 HCT120 3 12 300 34 1 208 HCT144 3 14 400 40 0 208 Table 1 2 3 4 5 6 GND L1 L1 L2 L2 A1 A2 3 8 copper 3 8 copper 3 8 copper Overheating limiter Sensor Figure 9 Electrical connections of 240 V 1 phase heaters HCT105 1 HCT120 1 HCT144 1 8 copper 8 copper 8 copper 2 3 4 5 6 GND L1 L2 L3 A1 A2 Overheating limiter Sensor Figure 10 Elec...

Страница 8: ...81205_NC ...

Страница 9: ... H Door Must open out and should not have a lock Size 2 0 x 6 8 with fir rails and double sealed tempered glass I Flooring concrete ceramic tile or heavyduty Vinyl with walking area of removeable SuperDek J Ventilation should be provided by lower vent close to heater 4 from floor and upper vent on opposite wall if possible 6 from ceiling or as low as 24 from floor Vents should be adjustable and sh...

Страница 10: ...concrete ceramic tile or a poured type of flooring When this is provided the Sauna can be easily cleaned and kept in a sanitary condition with little effort A carpet is NOT recommended for a Sauna A carpet becomes a perfect breeding ground for bacteria in the moist conditions of a Sauna and a carpet promotes the spread of foot diseases such as athlete s foot For the same reasons wooden duckboard s...

Страница 11: ... HEATER MODEL NUMBER DATE OF PURCHASE ORIGINAL OWNER ADDRESS PURCHASED FROM ELECTRICAL CONTRACTOR MUST SIGN HERE DATE OF ELECTRICAL WIRING HOOKUP THERMASOL 800 776 0711 least 30 minutes before water is poured over the stones only one or two dippers full of water should be poured over the hot stones at one time This guarantee will be void if a shower has been installed in the Sauna room This guaran...

Страница 12: ... 18 Terminal block 19 Heating element set 20 Terminal block sticker 21 Lead in plastic grommet 22 Floor mounting plate 23 Protective grille 24 Overheating limiter sensor bracket 25 Overheating limiter switch 26 Contactor bracket 27 4 pole contactor 28 Grounding terminal 1 2 1 4 5 6 HCT105 1 10 kW 1 2 3 4 5 6 1640 W 240 VI ZSS 110 HCT120 1 12 5 kW 1 3 5 1640 W 240 V I ZSS 110 2 4 6 2350 W 240 V ZSP...

Отзывы: