MAINTENANCE INSTRUCTIONS 

1.

Use only clean water on Sauna stones. 

Do not 

use spa or pool water as it will destroy your heater.

2. Clean water should always be used in Sauna buckets and water should be dumped out after every

use.  Scour buckets and dippers occasionally when film collects from usage.  Use plastic bucket

liner in  bucket  to prevent  water  leakage.

3.

Scrub benches with a soft brush,  using soap  and water or a mild disinfectant,  when needed­

about once a week in commercial Saunas,  or depending upon Sauna usage.  For sanitation, each

bather should  sit  or lie a on  towel  (this will  prolong  bench life).

4. Remove Super Dek and wash waterproof floor with disinfectant (e.g. Pine Sol) about once a week

or as  often  as needed. Hose off  Super  Dek to clean.

5.

To maintain beautiful appearance of Sauna heater, remove water stains by wiping with a damp

cloth  occasionally.

6. Heaters require no special maintenance when properly installed by a qualified electrical

contractor. After 5 years of usage, the rocks may need replacing if they have crumbled or

powdered.

7.

We strongly  recommend a floor that can  be  easily cleaned  (concrete, ceramic tile, or a poured

type of flooring). When this is provided, the Sauna can be easily cleaned and kept in a sanitary

condition with little effort. A carpet is  NOT recommended for a Sauna!  A carpet becomes a

perfect breeding ground for bacteria in the moist conditions of a Sauna;  and a carpet

promotes the spread of  foot diseases such as athlete's foot.  For  the same reasons, wooden

duckboard should not  be  used for  flooring.

8. In new construction,  a floor drain should also be provided,  especially in commercial Saunas for

sanitary cleaning and  maintenance.

9.

Seal wood around glass in door-inside and outside-with 

Thompson's  Water Seal 

to prevent

warpage.

10.

When Sauna wood becomes stained from perspiration, the wood may be lightly sanded with fine

sandpaper  to restore beautiful appearance.  We do not  recommend stains or  sealers  as  toxic

vapors may appear when heated. However, 2 coats of 

Thompson's  Water Seal 

may be used on

the wood benches in  a commercial  Sauna,  so that the wood may be more easily cleaned and

kept  sanitary-the wood will not absorb perspiration.

11.

The Sauna room will heat faster if the higher vent is kept in a closed position when heating. The

lower vent may always be kept in  an open  position.

12. Required warning signs should be posted according to the instructions.

10

81205_NC

Содержание F-2

Страница 1: ...e and guarantee IMPORTANT This manual must be left with owner manager or operator of Sauna after it is used by electrician MODEL HCT105 1 HCT120 1 HCT144 1 CONTROLS F 2T F 2 co M To UL STD 875 c us CERTIFIED TO CAN CSA STD 3159549 E60335 2 53 05 MODEL HCT105 3 HCT120 3 HCT144 3 CONTACTORS FX404 FX503 1 81205_NC ...

Страница 2: ...2 81205_NC ...

Страница 3: ...e 3 MODEL INPUT MIN HEIGHT FT HCT105 1 10 0 6 5 HCT105 3 HCT120 1 12 5 6 5 HCT120 3 HCT144 1 15 0 6 5 HCT144 3 Table 1 20 1 r w 1 r _ _J W t I a o ez o cor a FLOOR AREA MIN MAX SO FT SQ FT 60 94 78 114 97 146 HEATER MIN CLEARANCE FROM WALL AND FENCE 5 MIN 110 kW 6 MIN 112 5 15 kW 21 2 I WOOD FENCE Figure 4 HEATER MIN CLEARANCE FROM BENCHES 0 0 _ Figure 4A V SAUNA ROOM MIN SPACING FROM ADJACENT SUR...

Страница 4: ...es Use copper wire from load center to wall mounted contactor Supply cable must have 5 wires including insulated neutral plus separate ground Use 90 C copper wire from contactor to control and from control to room light Also use 90 C copper wire from contactor to Sauna heater within seal tight flex conduit and connect to junction box at heater with 90 connector Connect to the noted terminals and c...

Страница 5: ... wire from breaker to wall mounted contactor Supply cable must have 4 wires including insulated neutral plus separate ground Use 90 C copper wire from contactor to control and from control toroom light Also use 90 C copper wire from contactor to Sauna heater within seal tight flex conduit and connect tojunction box under heater at back with 90 connector Connect to the noted terminals and connect g...

Страница 6: ...81205_NC ...

Страница 7: ...per breaker to contactor contactor to heater HCT105 3 9 800 27 3 208 HCT120 3 12 300 34 1 208 HCT144 3 14 400 40 0 208 Table 1 2 3 4 5 6 GND L1 L1 L2 L2 A1 A2 3 8 copper 3 8 copper 3 8 copper Overheating limiter Sensor Figure 9 Electrical connections of 240 V 1 phase heaters HCT105 1 HCT120 1 HCT144 1 8 copper 8 copper 8 copper 2 3 4 5 6 GND L1 L2 L3 A1 A2 Overheating limiter Sensor Figure 10 Elec...

Страница 8: ...81205_NC ...

Страница 9: ... H Door Must open out and should not have a lock Size 2 0 x 6 8 with fir rails and double sealed tempered glass I Flooring concrete ceramic tile or heavyduty Vinyl with walking area of removeable SuperDek J Ventilation should be provided by lower vent close to heater 4 from floor and upper vent on opposite wall if possible 6 from ceiling or as low as 24 from floor Vents should be adjustable and sh...

Страница 10: ...concrete ceramic tile or a poured type of flooring When this is provided the Sauna can be easily cleaned and kept in a sanitary condition with little effort A carpet is NOT recommended for a Sauna A carpet becomes a perfect breeding ground for bacteria in the moist conditions of a Sauna and a carpet promotes the spread of foot diseases such as athlete s foot For the same reasons wooden duckboard s...

Страница 11: ... HEATER MODEL NUMBER DATE OF PURCHASE ORIGINAL OWNER ADDRESS PURCHASED FROM ELECTRICAL CONTRACTOR MUST SIGN HERE DATE OF ELECTRICAL WIRING HOOKUP THERMASOL 800 776 0711 least 30 minutes before water is poured over the stones only one or two dippers full of water should be poured over the hot stones at one time This guarantee will be void if a shower has been installed in the Sauna room This guaran...

Страница 12: ... 18 Terminal block 19 Heating element set 20 Terminal block sticker 21 Lead in plastic grommet 22 Floor mounting plate 23 Protective grille 24 Overheating limiter sensor bracket 25 Overheating limiter switch 26 Contactor bracket 27 4 pole contactor 28 Grounding terminal 1 2 1 4 5 6 HCT105 1 10 kW 1 2 3 4 5 6 1640 W 240 VI ZSS 110 HCT120 1 12 5 kW 1 3 5 1640 W 240 V I ZSS 110 2 4 6 2350 W 240 V ZSP...

Отзывы: