3
General:
This water heater is not intended for
use by persons (including children)
with reduced physical, sensory
or mental capabilities, or lack of
experience and knowledge, unless
they have been given supervision
or instruction concerning use of the
water heater by a person responsible
for their safety.
Children and animals should be
supervised to ensure they do not
interfere with the water heater.
DO NOT spray aerosols in the
vicinity of this water heater while it is
in operation.
DO NOT use or store flammable
materials or chemicals in or near this
water heater.
DO NOT modify this water heater.
DO NOT operate this water heater
with any panels or covers removed.
DO NOT place articles on or against
gas storage water heaters.
Relief Valve:
The Pressure & Temperature Relief
(PTR) Valve must be installed directly
into a socket marked “RELIEF VALVE”.
The drain line from this valve must not
be sealed or blocked.
The PTR Valve rating is shown on the
compliance plate. The valve must not
be tampered with or removed. Your
water heater must not be operated
unless this valve is fitted and in
working order.
The PTR Valve should be checked by
a licensed tradesperson for adequate
performance, or replaced at intervals
not exceeding 5 years, or less in areas
where local regulations apply.
The PTR Valve is to be operated
regularly to remove lime deposits and
to verify it is not blocked. It is normal
for the valve to leak a small amount of
water during heating cycles.
Danger:
Failure to operate the PTR Valve
easing lever at least once every six
months may result in the water heater
exploding.
Continuous leakage of water from the
PTR Valve may indicate a problem
with the water heater. This may be
caused by excessive water supply
pressure, a faulty PTR Valve or a faulty
thermostat.
Turn off the water heater and contact
Customer Service on 1300 412 612.
SAFETY INFORMATION