PACIFIC CLM360 ULTRA LIQUID COOLING KIT
CL-W335-CU12SW-A
Thermaltake recommends the following steps to be taken after completing your water loop setup
1. It is strongly recommended to use market proven pre-mix coolant, such as Thermaltake Coolant 1000. It offers great performance
while preventing the entire cooling system – copper, brass, nickel, aluminum, and steel – from corrosion.
2. Fill the reservoir with coolant and cycle the power on and off several times while the pump pushing the coolant into the loop.
3. DO NOT let the pump run dry, when there is no liquid entering the pump turn off your power immediately
4. Fill the reservoir to the top as it will prevent air from going into the pump
5. If necessary tilt the system slightly from side to side to bleed the air out of the loop.
6. Place some paper towels under fittings and joining points to test for leaks.
7. Run the loop with the fill port open for about 24 hours to completely bleed the air out of the loop.
Cutting and Attaching the Tubing
Measure the tube length based on the base
part of the fitting, and make (bend) the tubes.
The loop order : Pump Outlet > Water Block
Measure the tube length based on the base
part of the fitting, and make (bend) the tubes.
The loop order : Water Block > Radiator
Measure the tube length based on the
base part of the fitting, and make (bend)
the tubes. The loop order : Radiator >
Reservoir inlet
Fit the C-Pro fitting to the tube according
to the order in the picture below, Install the
tubes and tight the fitting caps.
Finished
3
3
2
2
1
1
4
5
Filling the System
CAUTIONS:
1. Before filling the system, please make sure
that each fitting as well as unused ports are
completely sealed.
2. If there is any case of leaking, immediately
turn off the power and clean the leak
3. If there is any related electronic parts stained
on liquid coolant, make sure to completely
clean and dry the components. And then
make sure they all work well.
After switching off the power supply, connect the PSU
power cord and product cables.
Use the refill bottle to fill coolant into the reservoir
Place your PSU outside of the case and attach it to the pumps 4pin molex
connector, turn on the power of PSU and make the rest of the system fills up.
CAUTION
CAUTION
The O-ring and the packing
with a groove on the inside
diameter must always be
installed towards the top of
the compression nut
Groove
5
Keep the reservoir cap dry!
Do not allow coolant to
access the wire and
the LED module
Caution!
After adding the recommended coolant, remember to fill the reservoir to only 80%
and leave the fill port cap off. This will help stabilize your internal loop pressure
23
20
25
29
29
28