AFTER SEASONAL OPERATION 
 

After the operational season or when the unit is to be stored, 
You should: 
 

1.  Turn off the air conditioner and remove the power source. 
2.  Clean Air Filter and outside of unit as explained earlier. 
3.  Open the Drain at the bottom rear of the unit. 
4.  Allow all condensation to drain, then close the drain. 
5.  Operate the unit for a few hours in fan only mode to dry any 

condensation from the inside of the unit. 

6.  Unit may be covered to prevent dust and dirt from entering unit during 

storage. 

 

 

SAFETY PRECAUTIONS 

 

 

CAUTION

 

 

 

Do not use in very small confined spaces 

 

Keep out of direct sunlight. Extended periods of exposure to direct 
sunlight will cause discoloration of unit. 

 

WARNING 

 

Do not operate in wet or extremely damp areas. 

 

Do not use near Gas appliances, fires, or in the vicinity of flammable 
liquids. 

 

SHOCK HAZARD 

 

 

Inspect Power cord regularly. Replace cord if frayed, broken, or 
otherwise damaged. 

 

Turn off unit before unplugging 

 

When unplugging the unit, hold the plug and remove from socket. DO 
NOT UNPLUG BY PULLING ON POWER CORD. 

 

Keep away from Televisions, and radios, to avoid the risk of 
electromagnetic interference. 

 

Do not block or restrict the Air inlet and outlets. 

 

Do not Tip or turn over. Do not store this unit on its side. 

 

Do not spray unit with Insecticides or other chemicals. 

 

Page 11 of 19

 

Содержание PAC9D

Страница 1: ...D DU UA AL L P PI IP PE E P PO OR RT TA AB BL LE E A AI IR R C CO ON ND DI IT TI IO ON NE ER R M MO OD DE EL LS S P PA AC C9 9D D 950 0013 revE Dec 26 2006 Page 1 of 19...

Страница 2: ...se by young children or without supervision 2 Young children should be supervised to ensure that they do not play with the appliance 3 The LCDI plug should be accessible after installation of the appl...

Страница 3: ...ally to be used in homes offices etc It has a compact design compared to others with the same cooling capacity This unit provides excellent functionality with low power consumption and a low noise lev...

Страница 4: ...Page 4 of 19...

Страница 5: ...CONTROL PANEL DISPLAY HEAT PUMP MODEL ONLY DISPLAY COOL ONLY MODEL Page 5 of 19...

Страница 6: ...IF REMOTE IS LOST Unplug unit for 10 seconds then reconnect power Unit will now function via the control panel Page 6 of 19...

Страница 7: ...air flow direction left or right The LCD display will show the swing icon 5 The operating ranges for cooling operation is 63 F 88 F 17 C 31 C Note In order to improve the cooling efficiency be carefu...

Страница 8: ...stop Note If timer is activated unit will not start until set time has elapsed If you have the power on off after 12 hours elapsed time pressing TIMER key again will cancel the timing To lock remote...

Страница 9: ...will turn off The WATER FULL indicator on the control panel will illuminate If the unit has a LCD failure code E5 will display Emptying Water Tank The water can be drained from the unit either by remo...

Страница 10: ...re installing 4 Install the air filter back to its original position If Air Filter is not excessively dirty a vacuum may be used in place of washing CLEANING OF THE AIR CONDITIONER Outside surface of...

Страница 11: ...all confined spaces Keep out of direct sunlight Extended periods of exposure to direct sunlight will cause discoloration of unit WARNING Do not operate in wet or extremely damp areas Do not use near G...

Страница 12: ...ve unit away from heat source Clean the air filter Re adjust the Set temperature Re adjust the fan speed Too noisy or Vibrates Is unit level Place unit on a flat level surface Machine starts and stops...

Страница 13: ...XHAUST HOSES 1 Fit one end of the exhaust hose to the exhaust port on the unit Turn 2 3 full turns to tighten the hose 2 Repeat for the Inlet hose 3 Straiten hoses to window Note length of hoses shoul...

Страница 14: ...s before Correct mounting shown below see Fig 1 Fig 2 Fig 3 If mounting in the wall the height of the hole should be between 16 and 51 400mm 1300mm Note There two exhaust hoses of this unit their inst...

Страница 15: ...If the air exhaust requires bending please see the diagrams below Incorrect Hose Mounting Fig 4 Air exhaust bend too large Page 15 of 19...

Страница 16: ...ry for you to improvise modify some aspects of the installation procedures for certain types of windows Please refer to Fig 5 Fig 6 for minimum and maximum window openings INSTRUCTIONS Install 2 screw...

Страница 17: ...hose with adapters 1 Kit contains 2 hoses and 2 adapters Stretches from 19 1 2 500 mm to 78 3 4 2000mm Window Exhaust adapter kit 1 2 pieces in kit Adjustable window slider kit 1 Fits windows from 26...

Страница 18: ...CURRENT INPUT 11 2 AMPS HEATING POWER INPUT N A HEATING CURRENT INPUT N A INDOOR DISCHARGE AIR FLOW 206 CF M RATED POWER INPUT 1420 WATTS RATED CURRENT INPUT 11 6 AMPS NOISE LEVEL 58 DB A REFRIGERANT...

Страница 19: ...ration period This warranty provides free replacement of defective parts only Labor and replacement as a result of normal wear and tear are not covered under this warranty Additional claims are exclud...

Отзывы: