ALWAYS REMOVE POWER
(Heat Pump Models Only)
1. Repeatedly press the MODE button to select the heat mode, The LCD
window shows ''HEAT''.
2. Press the TEMP + or TEMP - button to set a proper room temperature
Range. 63°F-88°F (17° to 31° C) .
3. Press FAN SPEED button to choose high, middle, or low fan speed.
4. Press SWING button to adjust the air flow direction, The LCD display will
show the swing icon.
TIMER SET FUNCTION
With unit off: pressing timer button on control panel or remote will set length of
time before unit turns on (press the HOUR button repeatedly to select hours
before start up to 12). The LCD window will show the clock on icon, and hours
to start.
With unit on: pressing timer button on control panel or remote will set length of
time before unit turns off (press the HOUR button repeatedly to select hours
before stop up to 12). The LCD window will show the clock on icon, and hours
to stop.
Note:
If timer is activated unit will not start until set time has elapsed.
If you have the power on/off after 12 hours elapsed time, pressing TIMER key
again will cancel the timing.
To lock remote unit and prevent settings being changed you may press the
TEMP+ and TEMP- buttons together for more than two seconds. Keypad will
lock, and the LCD display will show the lock icon. Press the two buttons again
to unlock the keys, and the lock icon will disappear.
RECYCLE PUMP FUNCTION AND WATER DRAINAGE
(Heat Pump model only)
When unit is operating in the DRY mode:
•
If the water level in the tank is normal, the recycle pump will operate
recirculating the water across the condenser coil, but the water pump
does not.
•
If the level in the water tank is high, the water pump will operate for 10
minutes.
•
If the water level drops, after 10 minutes, the machine will continue to
operate in normal working mode.
•
If the water level is high after 10 minutes, the water pump will stop
working and the machine will turn off, and the WATER FULL lamp on
the control panel will illuminate.
Page 8 of 19