Attach foam adhesive seal 
________________________________________________________ 
 
Attach foam adhesive seal along the bottom of the curtain 
Bottom channel. 

 

 

 
 
 
Position the Air Conditioner 
1. Center air conditioner in window. Check that lower rail of air  

conditioner is behind and against back side of windowsill. 
Lower window sash to hold cabinet in place. 

 

NOTE

: Your model may differ from the one shown.                                              

                                                                                                                                Complete Installation  
                                                                                                                              1. Insert foam seal behind the top of the lower window  
2. Pull left-hand curtain out until it fits into the window channel.                               sash and against the glass of the upper window. 
    Repeat with right-hand curtain.                                                                      
 
   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Attach side curtains to window 
______________________________________________ 

 
1. 

Insert one of the #8 x 3/4” slotted wood screws 
through left-hand curtain and into the window channel 
to fasten the curtain to the window sash. 

2. 

Repeat for the right-hand curtain. 

NOTE: 

Your model may differ from the one shown.

 

 
 
 
 
 
 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 

 

   2. Place window-lock bracket on top of lower window 

and against upper window sash.

 

   

3. Use a 3/32” drill bit to drill a starter hole though the 

hole in the bracket. 

  
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 

 
 
 
 

 

Содержание 420-0030

Страница 1: ...Page 1 of 14 WINDOW AIR CONDITIONER INSTALLATION AND OPERATION 950 0129 revA 03 03 09 CATALOG NO PRODUCT CODE WAC6115RB 420 0030 WAC8115RB 420 0031...

Страница 2: ...others is very important We have provided many important safety messages in this manual and on your appliance Always read and follow all safety instructions This is the safety alert symbol This symbol...

Страница 3: ...Tools Needed The location should provide Flat Blade and Phillips screwdrivers Tape measure Level Drill and 3 32 or smaller bit Scissors Utility Knife Parts Supplied on some models Check that all part...

Страница 4: ...in lower right corner of air conditioner when air conditioner is in cabinet The electrical ratings for your air conditioner are listed on the model and serial number label The model and serial number...

Страница 5: ...power supply cord into a grounded 3 prong outlet 2 Press RESET on some devices a green light will turn on 3 Press TEST Listen for a click Reset button will trip and on some devices a green light will...

Страница 6: ...oval The location where the power cord exits the air conditioner Should be no more than 4 ft 122cm from a grounded 3 prong outlet Do not block the louvers on the front panel Do not block the louvers o...

Страница 7: ...Installation 1 Insert foam seal behind the top of the lower window 2 Pull left hand curtain out until it fits into the window channel sash and against the glass of the upper window Repeat with right...

Страница 8: ...times it will default to the previous settings 2 Select mode See Mode 3 Select fan speed See Fan Speed 4 Set temperature See Temperature ______________________________________________________ MODE __...

Страница 9: ...urs 4 Press TIMER again or wait 10 seconds Timer indicator light will remain on Display will show current room temperature To set the timer to turn on the air conditioner changing the previous setting...

Страница 10: ...dicator light on air conditioner control panel will remain on To set Timer to turn on air conditioner changing the previous settings 1 Turn on air conditioner 2 Adjust Mode to Cool Fan Only or Power S...

Страница 11: ...______________________________________________________ Annual Maintenance Your air conditioner needs annual maintenance to help ensure steady top performance throughout the year Call your local author...

Страница 12: ...e cooling capabilities of your room air conditioner Room air conditioners are not designed to cool multiple rooms The filter is dirty or obstructed by debris Clean the filter The inside evaporator and...

Страница 13: ...size amps 15 15 Minimum Circuit Capacity amps 7 07 7 93 REFRIGERANT R22 R22 REFRIGERANT CHARGE lbs oz 0 792 12 7 0 968 15 5 SOUND dba H M L 61 59 57 63 61 59 4 WAY AIR ADJUSTMENT NO NO 2 WAY AIR SWING...

Страница 14: ...ion period This warranty provides free replacement of defective parts only Labor and replacement parts as a result of normal wear and tear are not covered under this warranty Additional claims are exc...

Отзывы: