AIR CONDITIONER CARE 

 

Your new air conditioner is designed to give you many years of 
dependable service. This section tells you how to clean and care for 
your air conditioner properly. Call your local authorized dealer for an 
annual checkup. Remember… the cost of this service call is your 
responsibility. 
_______________________________________________________ 

Cleaning the Air Filter 

The air filter is removable for easy cleaning. A clean filter helps 
remove dust, lint, and other particles from the air and is important for 
best cooling and operating efficiency. Check the filter every 2 weeks 
to see whether it needs cleaning. 

NOTE:

 Do not operate the air conditioner without the filter in place. 

1.   Turn off air conditioner. 
 
2. Remove air filter by sliding filter out from either side of unit. 
 
3.   Use a vacuum cleaner to clean the air filter. If air filter is very 
dirty, wash it in warm water with a mild detergent. Do not wash air 
filter in the dishwasher or use any chemical cleaners. Air dry filter 
completely before replacing to ensure maximum efficiency. 
 
4. Replace air filter by sliding filter back into either side of unit. 
 
 
 
 
 
 
 

_______________________________________________________ 

Cleaning the Front Panel 

 
1. Turn off air conditioner 
 
2. Remove the air filter and clean it separately. See Cleaning the Air 
Filter. 
 
3. Wipe the front panel with a soft, damp cloth. 
 
4. Air dry front panel completely. 
_______________________________________________________ 
 

Repairing Paint Damage 

 
Check once or twice a year for paint damage. This is very important, 
especially in areas near oceans or where rust is a problem. If 
needed, touch up with a good grade enamel paint. 
 

NOTE:

 To reduce paint damage during the winter, install a heavy 

duty cover over air conditioner cabinet. 
_______________________________________________________ 

Annual Maintenance 

 

Your air conditioner needs annual maintenance to help ensure 
steady, top performance throughout the year. Call your local 
authorized dealer to schedule an annual checkup. The expense of 
an annual inspection is your responsibility. 

______________________________________________________________________________________________________________________ 

TROUBLESHOOTING 

 

Before calling for service, try the suggestions below to see whether you can solve your problem without outside help. 
 
_______________________________________________________ 
Air Conditioner will not operate 
_______________________________________________________ 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

The power supply cord is unplugged.     

Plug into a grounded 3 

prong outlet. See “Electrical Requirements”. 
 
 
 
 
 
 
 
 

 

The power supply cord has tripped (Reset button has popped 
out). 

Press and release RESET (listen for click; Reset button will 

latch and remain in) to resume operation. 
 

A household fuse has blown, or a circuit breaker has tripped. 

Replace the fuse or reset the circuit breaker. If the problem 
continues, call an electrician. See “Electrical Requirements”. 
 

Depending on model, the Power button has not been pressed or 
the Fan control is turned to Off. 

Press POWER or turn the Fan 

control to an active setting. 
 

The local power has failed. 

Wait for power to be restored. 

 
_______________________________________________________ 

Air Conditioner blows fuses or trips circuit breakers 
_______________________________________________________ 
 
Too many appliances are being used on the same circuit.

 

Unplug or relocate appliances that share the same circuit. 
 

Time-delay fuse or circuit breaker of the wrong capacity is 
being used. 

Replace with a time-delay fuse or circuit breaker of the 

correct capacity. See “Electrical Requirements”. 
 

An extension cord is being used. 

Do not use an extension cord 

with this or any other appliance. 
 

You are trying to restart the air conditioner too soon after 
turning the unit off. 

Wait at least 3 minutes after turning the unit off 

before trying to restart the air conditioner. 
 
 
 
 
 

Содержание 420-0027

Страница 1: ...Page 1 of 19 WINDOW AIR CONDITIONER INSTALLATION AND OPERATION 950 0071 revA 05 25 07 CATALOG NO PRODUCT CODE WAC12115RB 420 0028 CATALOG NO PRODUCT CODE WAC12230MB 420 0027 WAC12115MB 420 0029...

Страница 2: ...y and the safety of others is very important We have provided many important safety messages in this manual and on your appliance Always read and follow all safety instructions This is the safety aler...

Страница 3: ...evel Drill and 3 16 or smaller bit Through the wall installation In addition to the tools listed above the following tools are Needed for through the wall installations Saw 1 2 5cm or thicker lumber W...

Страница 4: ...ings for your air conditioner are listed on the The wall opening measurements should be model and serial number label The model and serial number A Height 16 40 6cm plus twice the thickness of label i...

Страница 5: ...rom the ones shown 1 Plug power supply cord into a grounded 3 prong outlet 2 Press RESET 3 Press TEST Listen for a click Reset button will trip and pop out 4 Press and release RESET Listen for a click...

Страница 6: ...ure your air conditioner cabinet does not fall out of the channel to air conditioner cabinet opening during installation or removal The location where the power cord exits the air conditioner Should b...

Страница 7: ...into guides as far as it will go 6 Repeat above steps for left hand curtain Attach Foam Adhesive Seal _______________________________________________________ Attach foam adhesive seal along the bottom...

Страница 8: ...____________________________________ 1 Insert foam seal behind the top of the lower window sash and against the glass of the upper window 2 Place window lock bracket on top of lower window and against...

Страница 9: ...3 Connect green ground wire to cabinet base with ground screw Position ground wire pointing straight up Put excess ground wire between coil and air conditioner cabinet 4 Remove the 2 front panel screw...

Страница 10: ...eet of an appropriate electrical outlet When wall thickness exceeds 8 1 2 inches opening must be modified to allow air to enter side louvers on case see special instructions on back Do not install air...

Страница 11: ...ted Do not attempt to install unit in walls thicker than 11 3 4 inches While operation of all units is similar controls very from model to model Operating Controls section shows control panel of unit...

Страница 12: ...mode See Mode 4 Select fan speed See Fan Speed 5 Set temperature See Temperature ______________________________________________________ MODE ______________________________________________________ 1 P...

Страница 13: ...previous settings 1 Turn off air conditioner 2 Press TIMER Timer indicator light will flash Display will show remaining hours before air conditioner will turn on 3 Press the plus or minus button to c...

Страница 14: ...ir conditioner control panel will remain on To set Timer to turn on air conditioner keeping previous settings 1 Turn off air conditioner 2 Press TIMER Indicator light on air conditioner control panel...

Страница 15: ...E _______________________________________________________ Turn the TEMPERATURE control to a mid setting Adjust the air conditioner s performance by turning the Temperature control clockwise for maximu...

Страница 16: ...______________________________________________________ Annual Maintenance Your air conditioner needs annual maintenance to help ensure steady top performance throughout the year Call your local author...

Страница 17: ...e cooling capabilities of your room air conditioner Room air conditioners are not designed to cool multiple rooms The filter is dirty or obstructed by debris Clean the filter The inside evaporator and...

Страница 18: ...RCUIT BREAKER SIZE A 15 MIN CIRCUIT CAPACITY A 14 1 REFRIGERANT CHARGE lbs oz R22 1 34 21 5 1 34 21 5 1 34 21 5 SOUND dbA H M L 58 55 53 58 55 53 58 55 53 4 WAY AIR ADJUSTMENT Yes Yes Yes 2 WAY AIR SW...

Страница 19: ...ion period This warranty provides free replacement of defective parts only Labor and replacement parts as a result of normal wear and tear are not covered under this warranty Additional claims are exc...

Отзывы: