background image

Page 9 of 17 

 
 

 
 

Through-the-Wall Cabinet Installation 

NOTES: 

 

Handle air conditioner gently.

 

 

Be sure your air conditioner does not fall out of 
the opening during installation or removal.

 

 

The place where the power cord exits the air 
conditioner should be no more than 4 ft 
(122cm) from a grounded 3 prong outlet.

 

 

It is the customer’s responsibility and 
obligation to have this product installed by a 
qualified technician familiar with through-the-
wall room air conditioner installations.

 

 

Do not block the louvers on the front panel.

 

 

Do not block the louvers on the outside of the 
air conditioner.

 

Option 1 – Wood, Metal or Plastic molding 

When using a wood, metal or plastic molding, the 
wood frame should line up with inside wall as shown, 
 
 
 
 
 
 
 
 
 
 
 
 

Option 2 – Plastered wall with no molding 

If the plastered wall is to be flush with the cabinet 
and no molding used, the wood frame must be set 
½” 913mm) into the inside wall. 
 

 
 
 
 
 
 
 
 
 
 
 
 
Install Wood Frame 

1. 

Construct wood frame. See “Location 
Requirements” for dimensions.

 

2. 

Measure outside width and height of frame 
to determine wall opening dimensions.

 

3. 

Cut opening through the wall. Remove and 
save insulation.

 

 

Dimension for depth depends on wall 
thickness and type of molding.

 

 

Do not block louvers in air conditioner 
cabinet.

 

 

Use 1” (2.5cm) or thicker lumber for wood 
frame. 

 

4.  Apply wood preservative to the outside 

exposed surfaces. 

 
 
 
 
 
 
 
 
 
 
 
5.  Insert the frame in the wall opening. Square 

and level frame. 

6.  Attach frame securely to the wall. 
 

INSTALL CABINET INTO WOOD FRAME 
1. 

Remove top channel and both side channels 
using a ¼” nut driver or socket wrench. 
Discard top channel and both side channels. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

2. 

Insert cabinet into the framed wall opening. 
The top of the cabinet should extend ¾” 
(19.1 mm) into the room. If there is trim, the 
cabinet should extend ¾” (19.1mm) past the 
trim. 

 

 
 
 
 
 
 
 
 
 
 

Содержание 420-0018

Страница 1: ...Page 1 of 17 WINDOW AIR CONDITIONER INSTALLATION AND OPERATION 950 0011 revI 1 10 07 CATALOG NO PRODUCT CODE WAC18230R 420 0018 WAC24230R 420 0021 CATALOG NO PRODUCT CODE WAC24230M 420 0022...

Страница 2: ...ty of others is very important We have provided many important safety messages in this manual and on your appliance Always read and follow all safety instructions This is the safety alert symbol This...

Страница 3: ...ps Screwdrivers Tape measure Drill and 3 16 or smaller bit Level Parts supplied on some models NOTE Installation parts are supplied for double hung windows up to 40 101 6cm wide ______________________...

Страница 4: ...roperly grounded 3 prong outlet installed by a qualified electrical installer It is the customer s responsibility To contact a qualified electrical installer To assure that the electrical installation...

Страница 5: ...______________________________________________________________________________________ Unpacking Remove packaging materials Remove and dispose of recycle packaging materials Remove tape and glue resid...

Страница 6: ...abinet Using 4 10 x 3 8 washer head Phillips thread cutting screws attach top channel to air conditioner cabinet Attach Side Curtains Locate provided bag of screws Insert top and then bottom of right...

Страница 7: ...et and the inside of the window channel 3 Repeat for the left side Adjust the cabinet until the distance on each side is the same 4 use a 3 16 drill bit to drill 4 starter holes 3 8 deep through the 4...

Страница 8: ...of window 3 Use a 3 32 drill bit to drill starter holes through the holes in each bracket into the window sash 4 Attach both window lock brackets to window sash with a 10 x round head screw to secure...

Страница 9: ...ed wall is to be flush with the cabinet and no molding used the wood frame must be set 913mm into the inside wall Install Wood Frame 1 Construct wood frame See Location Requirements for dimensions 2 M...

Страница 10: ...against the glass of the upper window 2 Place one window lock bracket on top of lower window and against upper window sash on each side of window 3 Use a 3 32 drill bit to drill starter holes through...

Страница 11: ...ease or Decrease pads 3 Increase pad Used to increase set temperature when in Cool or Energy Saver mode The Set light will turn on while setting Used to increase the delay time when using the Timer fu...

Страница 12: ...ver pad a second time turns the Energy Saver mode off and the fan runs all the time while the compressor cycles on and off 10 Fan Only Mode Use the Fan Only Mode at Low Med or High fan speed to provid...

Страница 13: ...vel of comfort When you turn to the knob to a higher number the indoor air will become cooler Turn the knob to a lower number and the indoor air will become warmer CIRCULAIRE For continuous side to si...

Страница 14: ...Press and release RESET listen for click Reset button will latch and remain in to resume operation A household fuse has blown or a circuit breaker has tripped Replace the fuse or reset the circuit br...

Страница 15: ...e room Use a fan to exhaust heat or moisture from the room Try not to use heat producing appliances during the hottest part of the day The louvers are blocked Install the air conditioner in a location...

Страница 16: ...e LCDI LCDI LCDI Power Cord Length 6 6 6 Refrigerant R22 R22 R22 Refrigerant Charge oz lbs 27 84 1 74 33 44 2 09 33 44 2 09 Sound Level Inside Outside dba MAX 56 61 56 61 56 61 4 Way Air Adjustment YE...

Страница 17: ...ion period This warranty provides free replacement of defective parts only Labor and replacement parts as a result of normal wear and tear are not covered under this warranty Additional claims are exc...

Отзывы: