Thermal Edge CS011-D48 Series Скачать руководство пользователя страница 6

                                                                                                      

 

1800 Hurd Drive ● Irving, Texas 75038 ● (972) 580-0200 ● (888) 580-0202 ● Fax (972) 580-0277 

URL:  www.thermal-edge.com ● Email:  

[email protected]

 

SP-ENG-211-D48-02 Rev 2.3          | 

P a g e

                                                                                   

An air conditioner is designed to dehumidify and extract heat from an area, or provide heat to an area.  
The cooling is done using a simple refrigeration cycle.  A product of this simple refrigeration cycle is 
excess humidity that condenses to a liquid.   
 
Thermal Edge air conditioners are designed using an advanced refrigeration cycle and are equipped 
with a Condensate Removal System that changes the excess humidity liquid into a vapor which is then 
vented to the atmosphere.   In the event of excess water vapor when the enclosure door has been left 
open there is an overflow hole on the bottom of every unit.  Please contact Thermal Edge Inc. if you 
encounter excess water coming from your air conditioner. 

 

Preliminary Testing 
 

Before mounting the air conditioner to the enclosure, test for proper operation.  Follow the steps below 
prior to installation. 
 

 

WARNINGS 

The air conditioner must sit upright for 24 hours to assure the compressor oil has drained down to the 
compressor.  Check the unit label to assure the electric power available to the air conditioner is the 
proper voltage and phase.  Check the electric power source for proper ground wire and neutral wire 
installation per 2008 NEC.  Assure that the electric power is protected by a circuit protection device; 
refer to the Unit Specification section in this manual for proper circuit protection sizing.  

 

 

Connect a power source to the air conditioner and turn on the power switch.   The evaporator 
fan will start and the digital controller will power up. If cooling is called for, the compressor will 
start in 3 minutes. 

 

If desired, change the cooling set point.  Refer to Digital Temperature Controller Programming 
section on this manual for details on changing the set point.  Factory default settings should be 
satisfactory; however you may want to adjust heat, cooling and alarm set points for your 
specific application.  

 

The condenser fan is controlled by the refrigerant pressure and will turn on later when the 
operating pressure builds up.  This feature allows low ambient operation and reduces current 
inrush at initial power on. 

 

Run the air conditioner for 15 minutes; during this time the condenser fan will turn on after the 
condenser coil warms up.

 Note: Ambient Temperature must be at least 75°F.

 

 

Turn the unit off if the equipment makes any unexpected or hard mechanical noises or 
vibrations and refer to the troubleshooting guide in this manual. 

 

The supply cold air should be at least 10°F colder than the return air entering the unit.  If it is 
not, refer to the troubleshooting guide in this manual. 

 

When you are satisfied that the unit is operating properly, turn unit off, disconnect the power 
and mount the unit on the enclosure in accordance with the Mounting the Air Conditioner 
section in this manual. 

Содержание CS011-D48 Series

Страница 1: ...User Technical Manual CS011 D48 Series Rev 2 3...

Страница 2: ...Slotnick Updated warranty 2 0 02 19 2019 B Slotnick Updated mounting instructions alarm settings RMA procedure 2 1 06 18 2019 B Slotnick Updated preliminary testing instructions compressor protection...

Страница 3: ...4 Moving the Air Conditioner 5 Unit Label 5 Operation 6 Preliminary Testing 6 Mounting the Air Conditioner 7 Unit Specifications 8 Options 10 System Faults 13 Digital Temperature Controller Programmi...

Страница 4: ...ecting the Equipment Thermal Edge air conditioning equipment is designed manufactured and packed to prevent damage from normal handling shock and vibration during shipment It is necessary to inspect y...

Страница 5: ...to record the data from the label to the template below and keep this information in a safe place for warranty and ordering parts To prevent damage to equipment electrical panel and wiring and to pre...

Страница 6: ...e that the electric power is protected by a circuit protection device refer to the Unit Specification section in this manual for proper circuit protection sizing Connect a power source to the air cond...

Страница 7: ...t to let any cutting debris fall into the enclosure Hang the air conditioner on the easy hang flange and from inside the enclosure use the fasteners supplied to attach the air conditioner to the enclo...

Страница 8: ...mum Ambient 125 F Unit Weight 30 lbs 120VAC Model Operating Voltage Range Volts Loading Current Running Current Amps SCCR Short Circuit Current Rating Amps Recommended Fuse Selection Amps KVA Rating R...

Страница 9: ...Hurd Drive Irving Texas 75038 972 580 0200 888 580 0202 Fax 972 580 0277 URL www thermal edge com Email support thermal edge com SP ENG 211 D48 02 Rev 2 3 9 P a g e THIS PAGE IS INTENTIONALLY LEFT BL...

Страница 10: ...oint Default Settings 105 F Dry Contact High Temperature Alarm Set Point 2 F Recovery Differential 3min Temperature Alarm Delay At the default settings the Dry Contact initial conditions are normally...

Страница 11: ...the Digital Temperature Controller Programming section for details on all default settings Open Door Kill Switch This option provides you with an adjustable and mountable safety switch for your elect...

Страница 12: ...e presence of corrosive chemicals such as hydrogen sulfide chlorine etc Condenser and evaporator coils are available with electrostatically applied epoxy coating to prevent corrosion Three options are...

Страница 13: ...2 minute time delay A thermal overload protects the compressor against faults In the event that the snowflake status LED is on but is not flashing and the compressor is not running an internal fault...

Страница 14: ...value 4 Use the UP or DOWN arrow key to change its value 5 Press SET to store the new value and move to the following parameter To exit Press SET UP arrow keys or wait 15 seconds without pressing a k...

Страница 15: ...n Alarm Only 2 HA2 Condenser High Temperature Alarm P2 153 F for 3 minutes Compressor turned Off by pressure switch if temperature continues to rise 2 LA2 Condenser Low Temperature Alarm P2 50 F for 3...

Страница 16: ...and attached by plug in connections Compressor Thermal Edge uses hermetically factory sealed compressors that are quiet low vibration and are maintenance free Thermal overload devices are installed to...

Страница 17: ...mperature Probe Mounting Clip 52126 250C Thermal Expansion Value TXV 32023 1 Compressor 31659 1 Gasket Installation Kit 71410 CS01 Evaporator Fan 41002 2 1 Condenser Fan 41002 2 1 Note Qty 2 Safety In...

Страница 18: ...on position ON OFF Toggle Switch then Retry Verify input power meets voltage requirements as shown in the UL label YES If problem is still present contact technical support Unit Overheats Insufficient...

Страница 19: ...ssor Use meter3 Check for faulty evaporator fan3 Measure Temperature at Evaporator Verify Heat Load Requirements Is unit capacity adequate for internal head load Possible low refrigerant Is compressor...

Страница 20: ...ind controller CA YES NO Check Low Pressure Switch Connections and Verify Pressure switch is closed Use meter 3 P1 or P2 NO YES Check probe connections potential faulty probe LA LA2 HA HA2 YES Refer t...

Страница 21: ...g e Physical Dimensions Water overflow excessive Check drain is it plugged YES NO Clean condensate pan and drain add 1 tbsp bleach to upper pan monthly to kill mold Is Air Conditioner sealed against...

Страница 22: ...Hurd Drive Irving Texas 75038 972 580 0200 888 580 0202 Fax 972 580 0277 URL www thermal edge com Email support thermal edge com SP ENG 211 D48 02 Rev 2 3 22 P a g e THIS PAGE IS INTENTIONALLY LEFT B...

Страница 23: ...al edge com SP ENG 211 D48 02 Rev 2 3 23 P a g e Electrical Schematics System Schematic Digital Controller Schematic Note Schematics apply to all voltages optional accessories wiring not provided in t...

Страница 24: ...art except at the Thermal Edge factory in Dallas Texas Use of equipment for other than its designed purpose or operating conditions Operation in harsh oily corrosive or other abnormal environmental co...

Страница 25: ...Number Serial Number Customer name and contact info email phone number and address Shipping method Pack unit in a suitable packing for shipment preferably the original packaging if available Air Cond...

Страница 26: ...om the left connect the wires by inserting them into the lower receptacles located on the front of connector in the following order NOTE If using stranded wires it may be difficult to insert into the...

Отзывы: