background image

Manual   0-4805 Auto-Cut 200

A-4

APPENDIX

APPENDIX 4:  COMMAND-CONTROL PC BOARD LAYOUT (B)

H1

H1

C75

C75

C79

C79

C41

C41

R149R1

49

R144

R144

R148

R148

R103R1

03

C11C

11

U1

U1

11

D34

D34

11

U10

U10

R88

R88

R128R1

28

R39

R39

R73

R73

R118R1

18

R120

R120

C16

C16

R81

R81

29

29

22

11

J3

J3

30

30

R11

R11

11

U12

U12

D8D

8

D10

D10

TP6

TP6

SW6SW

6

U7

U7

11

R75R7

5

K5-E-STOPK5

-E

-S

TO

P

R20R2

0

R1R1

R151

R151

D37

D37

J5

J5

U14

U14

11

U5U

5

11

R139

R139

U13

U13

11

C56

C56

C22

C22

C50

C50

U6U

6

11

R10

R10

R14

R14

R2

R2

D6D

6

D29D

29

D12D

12

R104R1

04

C6

C6

R125R1

25

D20D

20

R47

R47

R5

R5

R82

R82

J36

J36

J4

J4

D18

D18

R77

R77

R72

R72

R9

R9

TP7

TP7

11

22

11

SW13

SW13

J35

J35

C3

C3

R131

R131

R13

R13

C53C

53

C78C

78

R62R6

2

C39

C39

C77C

77

C87C

87

C33

C33

R23R2

3

R132R1

32

U22

U22

11

R145

R145

C17

C17

K1-PSR

K1-PSR

D22D

22

R69R6

9

D21

D21

TP9

TP9

R76

R76

C26C

26

C58

C58

R64R6

4

U3

U3

11

R117R1

17

R6R6

R79

R79

R55

R55

C40

C40

C68C

68

C7C

7

R41R4

1

R44

R44

R8

R8

R66R6

6

R121

R121

D25D

25

D23

D23

R31

R31

R28R2

8

R45

R45

R123R1

23

R102R1

02

R135R1

35

C2C

2

D14

D14

C24

C24

TP3

TP3

U18U

18

11

R67R6

7

R49

R49

TP12

TP12

U23

U23

11

C45

C45

R57

R57

R138

R138

R127

R127

C76C

76

C66C

66

R12

R12

D26

D26

C19

C19

TP5

TP5

R38

R38

D7D

7

R53R5

3

C18

C18

D30

D30

R27R2

7

C47

C47

D17D

17

C30

C30

BB

AA

SW11SW

11

H2

H2

R71R7

1

U20

U20

H5

H5

J1

J1

H4

H4

R97

R97

H6

H6

H8

H8

R99

R99

H9

H9

C84

C84

19X2174

19X2174

D2D

2

11

11

R141

R141

11

11

11

11

11

11

R15

R15

11

11

REV

REV

C TDC 2005

C TDC 2005

C8

C8

ALL SW OFF FOR 50:1 (DEFAULT)A

LL

 S

W

 O

FF

 F

O

50

:1

 (D

EF

A

U

LT

)

SW12-1 ON FOR 16.7:1 (SC-11)SW

12

-1

 O

N

 F

O

16

.7

:1

 (S

C

-1

1)

U16

U16

OK TO MOVE SELECTO

TO

 M

O

VE

 S

EL

EC

T

CONTACTS

CONTACTS

11

DC VOLTS

DC VOLTS

+

+

+

+

+

+

C93

C93

+

+

+

+

U17

U17

11

11

+

+

+

+

+

+

R43

R43

H10

H10

H11

H11

OK CNC

OK CNC

R46

R46

PSR

PSR

CNC_E-STOP

CNC_E-STOP

CNC_START

CNC_START

HOLD_START

HOLD_START

R115R1

15

CNC PREFLOW

CNC PREFLOW

GAS ONG

A

O

N

E-STOP_PSE-

ST

O

P_

PS

C65C

65

C35C

35

U24

U24

11

+

+

GND

GND

+5V

+5V

R80

R80

+15V

+15V

-15V

-15V

+15V

+15V

-15V

-15V

R87

R87

+18V

+18V

GND

GND

ISOLATED

ISOLATED

PILOT

PILOT

R56

R56

DEMAND

DEMAND

CUT

CUT

DEMAND

DEMAND

ARC V-

ARC V-

R114

R114

PILOT V

PILOT V

CC POT

CC POT

D3

D3

TP8

TP8

R26R2

6

K7-GAS ONK7

-G

A

O

N

C34C

34

U19

U19

L2

L2

C27C

27

R29R2

9

C83

C83

+

+

R90

R90

C69C

69

+ +

C52C

52

U2

U2

11

C48

C48

U9

U9

11

R129R1

29

R50

R50

C15

C15

TB1

TB1

R59

R59

C20C

20

R83R8

3

C82

C82

D9

D9

C4

C4

C23

C23

C55C

55

R147

R147

C88

C88

C95

C95

++

K2-START

K2-START

C46

C46

R61

R61

R109

R109

D4

D4

D32

D32

J9

J9

Q1

Q1

R143

R143

C71

C71

C49C

49

R91

R91

R24R2

4

R60

R60

J6

J6

R22R2

2

R142R1

42

R21R2

1

R7

R7

R108

R108

R63

R63

R40

R40

R101

R101

R37

R37

C5

C5

C64C

64

C92C

92

T1T1

R30

R30

J8

J8

R134R1

34

R119R1

19

R116R1

16

R89

R89

R48R4

8

+

+

K3-E-STOP CNC

K3-E-STOP CNC

R78

R78

D36

D36

D31

D31

R140

R140

R107

R107

C37

C37

R65

R65

R100

R100

C28C

28

R84

R84

U11

U11

11

K4-OK

K4-OK

D1D

1

C73C

73

R25R2

5

R110

R110

C54

C54

D15

D15

R133

R133

R150

R150

R122R1

22

R19R1

9

C31

C31

TP11

TP11

D39

D39

29

29

22

11

J2

J2

30

30

D38D

38

R86

R86

R68

R68

R42R4

2

D13

D13

R126

R126

R70R7

0

R3

R3

C80

C80

R96

R96

U4

U4

TB2

TB2

11

C21C

21

K6

K6

C85

C85

++

R33R3

3

C70

C70

D40

D40

R17R1

7

C51C

51

R136R1

36

TP4

TP4

D28

D28

R93

R93

R52R5

2

C9C

9

TP14

TP14

D16

D16

C61C

61

D35

D35

C13C

13

R58

R58

D5D

5

R85

R85

R98

R98

R94R9

4

C89

C89

C62

C62

C25

C25

R74

R74

R130

R130

TP1

TP1

J7

J7

TP13

TP13

C91

C91

R35R3

5

TP10

TP10

R18R1

8

C29C

29

C72

C72

C42

C42

C74

C74

D19

D19

R4

R4

+

+

R124R1

24

R95

R95

C81

C81

D11D

11

R54R5

4

C36C

36

D24

D24

C12C

12

C86C

86

U21

U21

11

U15

U15

R16R1

6

11

L1

L1

TP2

TP2

C60

C60

R32R3

2

++

R51R5

1

U8

U8

C32

C32

11

C14C

14

D27D

27

R113

R113

D33D

33

C38

C38

R105

R105

R34R3

4

R92

R92

C59

C59

R112

R112

R106

R106

H3

H3

R146

R146

R111

R111

R36R3

6

C10C

10

C57C

57

11

22

25

25

26

26

11

22

33

33

34

34

+29-41 VDC

+29-41 VDC

C67

C67

C63

C63

C90

C90

R223R2

23

C94C

94

R155

R155

C1

C1

R158

R158

D60D

60

R156

R156

33

22
11

11

SW12SW

12

44

R154R1

54

R157

R157

D61D

61

SW12-2 ON FOR 30:1SW

12

-2

 O

N

 F

O

30

:1

SW12-3 ON FOR 40:1SW

12

-3

 O

N

 F

O

40

:1

SW12-4 SPARESW

12

-4

 S

PA

RE

+

+

+

+

R152R1

52

C44

C44

H7

H7

R224

R224

R225

R225

C43

C43

R227R2

27

R228R2

28

Q2

Q2

R226R2

26

Q3

Q3

AD+

AD+

Art # A-06901

TP14

TP7

TP6

J1

SW6

SW12

J36

TB1

TB2

J4

J9

TP11

J5

J6

J7

SW11

TP9

J8

TP12

J2

TP10

TP8

J35

TP4

TP3

TP2 SW13

TP5

TP1

TP13

J3

Содержание VICTOR 200 AUTO-CUT

Страница 1: ...on ___ tab here sheet At Section 8 insert the torch information section Insert the assembled manual sections and tabs into the 3 ring binder Keep this manual with the power supply for installation ope...

Страница 2: ...Thispageintentionallyblank...

Страница 3: ...Cutting System Cut out one strip and use as spine label in binder Discard extras Use next page as front cover insert in binder ManualNo 0 4805 Auto Cut 200 Plasma Cutting System Auto Cut 200 Plasma C...

Страница 4: ...Thispageintentionallyblank...

Страница 5: ...PLASMA CUTTING SYSTEM 200 AUTO CUT Rev AR Date January 8 2013 Manual 0 4805 OperatingFeatures Operating Manual...

Страница 6: ...Thispageintentionallyblank...

Страница 7: ...Rev AR Date January 8 2013 Manual 0 4805 OperatingFeatures PLASMA CUTTING SYSTEM 200 AUTO CUT Operating Manual...

Страница 8: ...please take the time to read the entire manual especially the Safety Precautions They will help you to avoid potential hazards that may exist when working with this product YOU ARE IN GOOD COMPANY Th...

Страница 9: ...9 2010 2011 2012 2013 by Victor Technologies All rights reserved Reproduction of this work in whole or in part without written per mission of the publisher is prohibited The publisher does not assume...

Страница 10: ...Thispageintentionallyblank...

Страница 11: ...INSERT TABLE OF CONTENTS TAB HERE DISCARD THIS SHEET...

Страница 12: ...Thispageintentionallyblank...

Страница 13: ...anel Features 2 4 2 09 Gas Requirements 2 5 2 10 Gas Applications 2 5 2 11 XTTM 301Torch Specifications 2 6 SECTION 3 INSTALLATION 3 1 3 01 Installation Requirements 3 1 3 02 Cables and Leads Identifi...

Страница 14: ...ower Supply Replacement Parts Right Side 6 7 6 08 Power Supply Replacement Parts Front Panel 6 8 6 09 Power Supply Replacement Parts Front Panel 6 9 6 10 Power Supply Replacement Parts Right Side 6 10...

Страница 15: ...opper Pilot Cont A 16 Appendix 8 Power Supply Schematic 230 460V Resistor Pilot A 18 Appendix 8 Power Supply Schematic 230 460V Resistor Pilot Cont A 20 Appendix 9 Power Supply Schematic CCC 400V Chop...

Страница 16: ...TABLE OF CONTENTS...

Страница 17: ...Insert Section 1 tab here Discard this sheet...

Страница 18: ......

Страница 19: ...y Arsenic Cobalt Nickel Barium Copper Selenium Beryllium Lead Silver Cadmium Manganese Vanadium Always read the Material Safety Data Sheets MSDS that should be supplied with the material you are using...

Страница 20: ...fety Code 25249 5 et seq 1 03 Publications Refer to the following standards or their latest revisions for more infor mation 1 OSHA SAFETY AND HEALTH STANDARDS 29CFR 1910 obtainable from the Superinten...

Страница 21: ...zone de respiration Gardez votre t te hors de la plume de fum e provenant du chalumeau Utilisez un appareil respiratoire alimentation en air si l a ration fournie ne permet pas d liminer la fum e et...

Страница 22: ...es de s curit munies de parois lat rales ou des lunettes de protection ou une autre sorte de protec tion oculaire Portez des gants de soudeur et un v tement protecteur appropri pour prot ger votre pea...

Страница 23: ...rican Welding Society 550 N W LeJeune Rd Miami FL 33126 8 Norme 51 de l Association Am ricaine pour la Protection contre les Incendies NFPA LES SYSTEMES GAZ AVEC ALIMENTATION EN OXYGENE POUR LE SOUDAG...

Страница 24: ...Underwriters Laboratory rating 94VO flammability testing for all printed circuit boards used CENELEC EN50199 EMC Product Standard for Arc Welding Equipment ISO IEC 60974 1 BS 638 PT10 EN 60 974 1 EN5...

Страница 25: ...therewith such as the performance or breach thereof or from the manufacture sale delivery resale or use of any goods covered by or furnished by Thermal whether arising out of contract negligence stric...

Страница 26: ...of goods to Cigweld or our Nominated Accredited Distributor Accredited Service Provider are the responsibility of the consumer This warranty is given Cigweld Pty Ltd A B N 56007226815 71 Gower Street...

Страница 27: ...Insert Section 2 tab here Discard this sheet...

Страница 28: ......

Страница 29: ...liquid coolant for the torch and leads 2 03 Gas Control Module Arc Starter This module mounts to the top of the power supply This module enables the operator to select gas set pressures and flows and...

Страница 30: ...Freq 3 Ph 3 Ph Fuse Amps Wire AWG Volts Hz kVA Amps 3 Ph 3 Ph 208 60 47 130 160 22 230 60 49 125 150 22 400 50 54 77 100 21 400 CE 50 54 77 100 21 460 60 59 75 90 21 Auto Cut 200 Power Supply 2 Extra...

Страница 31: ...ual No 0 4805 Auto Cut 200 2 3 SPECIFICATIONS Art A 04822 33 inch 840 mm 27 inch 680 mm 37 75 inch 960 mm 41 25 inch 1050 mm 27 5 inch 700 mm 48 75 inch 1238 mm 397 lb 180 kg 2 07 Power Supply Dimensi...

Страница 32: ...Coolant Connections Input Power Terminals Pilot Pos Terminal Circuit Breaker Panel Terminal Cover AC Power Lamp Ground Terminals Gas Control Connector RETURN SUPPLY Art A 04823 CNC Connection Arc Star...

Страница 33: ...5 Argon Hydrogen H35 35 Hydrogen 65 Argon 99 995 Purity gas recommended 120 psi 8 3 bar 827 kPa 200 scfh 5664 l h H2O Water See Note 2 50 psi 3 5 bar 10 gph 38 lph Auto Cut 200 BASIC Power Supply Gas...

Страница 34: ...ONS 2 11 XTTM 301 Torch Specifications A Torch Dimensions 2 25 57 15 mm 2 0 50 8 mm 2 39 60 81 mm 1 49 37 8 mm 19 00 482 68 mm 15 50 393 78 mm 2 74 69 55 mm 1 57 39 96 mm 3 54 89 87 mm 6 30 160 10 mm...

Страница 35: ...ode Tip Plasma Gas Distributor Shield Gas Distributor Shield Cap D Parts In Place PIP The torch is designed for use with a power supply which senses coolant return flow to confirm that torch parts are...

Страница 36: ...0 Amps Voltage Vpeak 500V Arc Striking Voltage 10kV Current Up to 200 Amps DC Straight Polarity See Note Plasma Gases Compressed Air Oxygen Nitrogen H35 F5 Shield Gases Compressed Air Oxygen Nitrogen...

Страница 37: ...Manual No 0 4805 Auto Cut 200 2 9 SPECIFICATIONS Insert Sec 3 tab here Discard this sheet...

Страница 38: ......

Страница 39: ...reference only The installation must conform to national and local codes for the type and method of wire being used Gas Supply The customer must supply all gases and pressure regulators Gases must be...

Страница 40: ...power Control Cable Ground Cable Work Art A 07231_AB Torch Work Cable Auto Cut Power Supply Arc Starter Gas Control Module GCM 1000 Pilot Return Negative Coolant Supply Coolant Return Control Cable CN...

Страница 41: ...Leads Power Supply to Arc Starter 1 0 50 mm Cable Pilot Return Power Supply to Arc Starter Negative Lead Power Supply to Arc Starter Control Cable Power Supply to Arc Starter Ground Cable Ground Cabl...

Страница 42: ...and equipment damage Use all four lifting eyes when using lifting straps to lift the power supply Useaforklift crane orhoisttolifttheunitofftheshippingpalletasshown Keepthepowersupplysteadyandvertica...

Страница 43: ...cted to the power supply Refer to local and national electrical codes for suggested cable and fuse sizes Remove the connections cover on the rear of the Power Supply Use caution when removing the pane...

Страница 44: ...The input voltage configuration is shown at the top of the board 2 If necessary disconnect the jumper from the top right corner of the board remove the board and re install with the correct input volt...

Страница 45: ...ound terminal block CAUTION The clear connections cover must remain in place 4 If required pass a system ground cable F1 through the last opening in the connections cover support panel next to the inp...

Страница 46: ...0 Ground Cable CNC Device Torch Cutting Table Cutting Machine Gantry 1 0 Work Cable Remote Arc Starter RAS 1000 1 0 Ground Cable Star Ground on Cutting Table Auto Cut W RAS Star Ground on Cutting Tab...

Страница 47: ...6 m Maximum 1 0 Ground Cable 4 AWG Ground Factory Installed GCM 1000 Gas Control Module Auto Cut Power Supply Star Ground Earth Ground Rod 1 0 Ground Cable F1 CNC Device Torch Cutting Table Cutting Ma...

Страница 48: ...ground wire and the Gas Control Module should use minimum 4 AWG wire The connection point must be to clean bare metal rust and paint make poor connections For all components wires larger than the rec...

Страница 49: ...his test assumes the 115 or 230 VAC source neutral is connected to the utility earth ground Art A 07252 WARNING Use extreme caution This test uses live voltage NEUTRAL Earth Grounded HOT On 115V AC Li...

Страница 50: ...ork Cable 1 Pass the end of the work cable upward through the leads bracket at the bottom of the power supply rear panel then up through the opening in the connections cover support panel 2 Refer to t...

Страница 51: ...805 Auto Cut 200 3 13 INSTALLATION 3 08 Connect Gas Supply Lines 1 Connect the gas supply lines to the appropriate input ports as shown RETURN SUPPLY RETURN SUPPLY Art A 04844 Plasma Gas In Shield Gas...

Страница 52: ...09 Connect CNC Cable 1 Connect one end of the CNC cable to the power supply receptacle marked CNC 2 Connect the other end of the cable to the CNC device 3 The CNC cable shield must be attached to grou...

Страница 53: ...0 1 Seconds SW 1 4 Pilot Delay 2 OFF 3 ON 4 OFF 0 2 Seconds 2 ON 3 ON 4 OFF 0 4 Seconds 2 OFF 3 OFF 4 ON 0 8 Seconds 2 ON 3 OFF 4 ON 1 0 Seconds 2 OFF 3 ON 4 ON 1 5 Seconds 2 ON 3 ON 4 ON 2 0 Seconds...

Страница 54: ...0VAC 1A Factory default setting or DC Volts 16 18vdc up to 100 ma SW 11 Analog Current Control B from Gas Control Factory default setting or A from CNC Position A requires that SW 8 2 be ON SW 12 1 2...

Страница 55: ...tion to the full non divided arc voltage Also available on the terminal strip are 120VAC 120 0 and 24 VAC 24 0 Note that the two 0 s are not common The allowable current draw is 100ma 120VAC and 1Amp...

Страница 56: ...kink or bend the leads 3 Inside the module slide the leads clamp over the leads 4 Connect the leads to the module in the sequence shown Coolant leads and connectors are color tagged red for coolant r...

Страница 57: ...onnection Tagged Red Art A 04832 Plasma Gas Connection Shield Gas Connection Torch Leads 5 Fold the end of the leads outer jacket back over the connection ring inside the module Slide the leads clamp...

Страница 58: ...Manual No 0 4805 Auto Cut 200 3 20 INSTALLATION Clamp 5 Art A 04935_AB Inner Shield Connection for OLDER LEADS ONLY...

Страница 59: ...mounting tube Slide the torch mounting tube onto the leads far enough to expose the fittings on the ends of the leads 4 Connect the Torch Head to the torch leads Follow the sequence shown Do not let t...

Страница 60: ...o the Torch Speed Charts to select the correct parts for the application The application will deter mine which torch parts must be used Refer to the speed charts for the proper torch parts to install...

Страница 61: ...ap Protrudes 0 063 0 083 1 6 2 1 mm Electrode Plasma Gas Distributor Tip Shield Gas Distributor Shield Cap O Ring on Tip 1 Stack Parts 2 Press Cartridge onto Stacked Parts 4 Check Shield Cap Protrusio...

Страница 62: ...ield Cup Art A 04344 InstallingShieldCupOntoCartridge 6 Take the removal tool off the cartridge Fit the cartridge assembly onto the torch head The cartridge should seal to the large O ring on the torc...

Страница 63: ...Protrusion 8 Slide the ohmic clip over the shield cup if using ohmic torch height sensing NOTE Ohmic height sensing is not recommended with water shield Water on the plate interferes electrically with...

Страница 64: ...rch leads length 2 Replace the cap on the tank Cat Number and Mixture Mixture Protects To 7 3580 Extra CoolTM 25 75 10 F 12 C 7 3581 Ultra CoolTM 50 50 27 F 33 C 7 3582 Extreme CoolTM Concentrate 65 F...

Страница 65: ...lant c Place the ON OFF switch to OFF d After 10 seconds place the ON OFF switch to ON again e Repeat steps b through d until the system no longer shuts down Depending on the length of the torch leads...

Страница 66: ...This Page Intentionally Blank...

Страница 67: ...Insert Sec 4 tab here Discard this sheet...

Страница 68: ......

Страница 69: ...power on TEMP Lamp Normally OFF Lamp will come ON when the internal temperature sensors detect tempera tures above normal limits Let the unit cool before continuing operation GAS Lamp Normally ON Indi...

Страница 70: ...eter and Control Knob GCM 1000 A CUT OUT Run Set Selector Use SET position to adjust plasma and shield pressures and flows Once these are set switch to RUN position for operation Plasma and Shield Gas...

Страница 71: ...or plug unit in to supply primary power to the system D Work Cable Connection Check for a solid and clean work cable connection to the workpiece or cutting table The connection area must be free from...

Страница 72: ...rn the knob to adjust gas pressure d Push the knob back in to lock the pressure setting 3 To set the Shield Gas pressure Set the Shield Mode Selector switch to the GAS or H2 O MIST position For Gas Sh...

Страница 73: ...angle between the surface of the cut edge and a plane perpendicular to the surface of the plate A perfectly perpendicular cut would result in a 0 bevel angle Top Edge Rounding Rounding on the top edge...

Страница 74: ...cut along an inside diameter of a circle the torch should move counterclockwise around the circle To keep the square edge along an outside diameter cut the torch should travel in a clockwise direction...

Страница 75: ...O Art A 04842 3 Check the AC lamp If lamp is ON AC input power is present in the power supply Circuitry in the power supply monitors the status of various conditions If the circuitry detects a situati...

Страница 76: ...Pilot arc is established 9 Move Torch within transfer distance of workpiece a Main arc transfers to the workpiece Pilot arc shuts off 10 Complete cutting operation 11 Stop the torch a Main arc stops...

Страница 77: ...te the pilot arc any longer than necessary 3 Use care in handling torch leads and protect them from damage 4 When using water as the shield note the following Use clean drinking quality tap water to h...

Страница 78: ...ctive during ramping and cutting Possible double arc 1 8 Shorted Torch Electrode to tip voltage 50v w inverter on 2 1 Missing Phase 1 of 3 input AC phases missing 2 2 Input voltage out of tolerance Te...

Страница 79: ...k add as needed 4 3 Coolant Overheated over 158 F 70 C Coolant temperature must drop by 9 F 5 C to clear overtemp condition 4 4 Cooling System Not Ready Pump has run 30 sec w o reaching minimum flow r...

Страница 80: ......

Страница 81: ...Insert sec 5 tab here discard this sheet...

Страница 82: ......

Страница 83: ...racks or abrasion Replace as needed Clean water filter if using H2O Mist Six Months Replace coolant filter Clean coolant tank Vacuum out any dust buildup inside power supply 5 02 Coolant Filter Cleani...

Страница 84: ...ield Clean the filter as follows 1 Disconnect system from main input power 2 Unscrew and remove the filter bowl by hand Be sure to keep the gasket 3 Remove and clean the filter Re install the bowl tig...

Страница 85: ...input power and turn it on to allow the pump to empty the tank The pump will run approximately for 20 seconds before the flow switch causes an interlock This procedure may be repeated a few times unt...

Страница 86: ...nnect Faulty EMI filter Voltage Resistor measurement Replace Loose fitting s Visual inspection Tighten fittings Failure to braze joints L1 Visual inspection Replace HF Coil Damaged or punctured coolan...

Страница 87: ...05 Auto Cut 200 5 5 MAINTENANCE 5 06 Arc Starter Spark Gap Adjustment 1 Shut off input power Remove the top console cover 2 Adjust the spark gap as shown Re install the top cover 0 063 0 002 1 6 0 05...

Страница 88: ...Manual No 0 4805 Auto Cut 200 5 6 MAINTENANCE This page is blank intentionally...

Страница 89: ...Manual No 0 4805 Auto Cut 200 5 7 MAINTENANCE Insert Sec 6 tab here discard this sheet...

Страница 90: ......

Страница 91: ...01 Replacement Power Supply Complete Unit Component Catalog Numbers Catalog Number Auto Cut 200 Power Supply 208 230V 3 9112 1 Auto Cut 200 Power Supply 460V 3 9112 2 Auto Cut 200 Power Supply 400V 3...

Страница 92: ...lot Return Cable only 4 ft 1 2 m 9 4890 B Negative Cable only 9 4892 C Hose Coolant Supply only 9 4886 D Hose Coolant Return only 9 4888 E Control Cable only Power Supply to Arc Starter 4 ft 1 2 m 9 4...

Страница 93: ...lot Return Power Supply to Arc Starter Negative Lead Power Supply to Arc Starter Control Cable Power Supply to Arc Starter Ground Cable Ground Cable Arc Starter To Earth Ground O P Control Cable Power...

Страница 94: ...alog 1 1 Power Supply Front Panel N A 2 1 Power Supply Rear Panel N A 3 1 Power Supply Top Panel 9 0445G 9 0445B 4 1 Power Supply Right Side 9 0442G 9 0442B 5 1 Power Supply Left Side 9 0443G 9 0443B...

Страница 95: ...Manual No 0 4805 Auto Cut 200 6 5 Parts List 6 05 Power Supply Replacement Parts Right Side Item Qty Description Ref Des Catalog 1 1 Heat Exchanger Fan FAN1 9 9338 2 1 Radiator 9 9339 1 2 Art A 08308...

Страница 96: ...wer Supply Replacement Parts Right Side Item Qty Description Ref Des Catalog 1 1 Output Filter PC PCB8 9 9341 2 1 Sensor HCT2 9 9368 3 1 Magnetic Contactor pilot MC2 9 9343 4 1 Resistor R6 9 9340 5 1...

Страница 97: ...ual No 0 4805 Auto Cut 200 6 7 Parts List 6 07 Power Supply Replacement Parts Right Side Item Qty Description Ref Des Catalog 1 Chopper Module 9 9389 1 Sensor HCT1 9 9342 Chopper Module Art A 08311 HC...

Страница 98: ...0 4805 Auto Cut 200 6 8 Parts List 6 08 Power Supply Replacement Parts Front Panel Item Qty Description Ref Des Catalog 7 1 Main Power Switch Circuit Protector CP1 9 9344 for 230 400 460 VAC units 7 A...

Страница 99: ...ts List 6 09 Power Supply Replacement Parts Front Panel Item Qty Description Ref Des Catalog 1 PC Board PCB3 9 9365 1 PC Board 230 460VAC PCB4 9 9370 1 PC Board 600VAC PCB4 9 9492 1 Display PC Board P...

Страница 100: ...0 6 10 Parts List 6 10 Power Supply Replacement Parts Right Side Item Qty Description Ref Des Catalog 1 1 PCBoard 230 400 460VAC PCB1 9 9362 1 1 PCBoard 600VAC PCB1 9 9491 2 1 Magnetic Contactor MC1 M...

Страница 101: ...Circuit Breaker AGC 125V 2 5A 120VAC 1A CP5 9 9348 16 1 Circuit Breaker AGC 125V 2 5A 15VDC 1A CP6 9 9348 17 1 Circuit Breaker Pump 250V 10A 200VAC 3A CP7 9 9351 18 1 Circuit Breaker Fan 125V 3 15A 24...

Страница 102: ...Power Supply Replacement Parts Right Side Item Qty Description Ref Des Catalog 1 1 Resistor R7 9 9363 2 1 Rectifier Diode D1 9 9345 3 1 Transformer T1 9 9355 for 230 460 VAC units 4 1 Diode D2 9 9486...

Страница 103: ...Cut 200 6 13 Parts List 6 13 Power Supply Replacement Parts Item Qty Description Catalog 29 2 Inverter Module 208 230V 9 9360D 2 Inverter Module 400V CE and 400V Non CE 9 9482D 2 Inverter Module 600V...

Страница 104: ...Manual No 0 4805 Auto Cut 200 6 14 Parts List 6 14 Power Supply Replacement Parts Right Side Item Qty Description Ref Des Catalog 30 1 Sensor Thermistor TH1 9 9361 30 Art A 04787...

Страница 105: ...Cut 200 6 15 Parts List 6 15 Power Supply Replacement Parts Item Qty Description Ref Des Catalog 1 1 Relay PC Board PCB7 9 9366 2 1 24 VDC Power Supply N A N A 3 1 Internal Control PC Board PCB5 9 93...

Страница 106: ...ment Parts Right Side Item Qty Description Ref Des Catalog 22 1 Sensor Level Switch LSW1 9 9354 24 1 Motor M 9 9381 25 1 Pump Check Valve Bypass Valve Assembly 9 9380 26 1 Bypass Valve part of assembl...

Страница 107: ...Catalog 1 1 Assembly CCM Auto Cut 9 9418 2 1 Plate CCM Face 9 9419 3 1 Panel CCM Mount Not Available 4 1 Harness CCM I O Board 9 9421 NOTE This page covers parts for Command Control module without an...

Страница 108: ...ox Arc Starter 9 4989 12 1 Mount Neg Lead Attach 9 4990 13 1 Bracket Gas Box Arc Starter 9 4991 14 1 Bracket Filter Water Mist 9 4992 15 1 Hose Package 9 4993 16 1 Harness Gas Controls 9 4994 17 1 Har...

Страница 109: ...Manual No 0 4805 Auto Cut 200 6 19 Parts List Art A 04852_AC Right Side Left Side 9 5 6 7 8 10 13 15 14 11 12 3 17 16 20 19 21 26 27 23 24 25 22 28 29...

Страница 110: ...Manual No 0 4805 Auto Cut 200 6 20 Parts List This Page Intentionally Blank...

Страница 111: ...Manual No 0 4805 Auto Cut 200 6 21 Parts List Insert Sec 7 tab here discard this sheet...

Страница 112: ......

Страница 113: ...d Cup Cartridge Assembly stationary Turn the Shield Cup to re move it from the Cartridge Assembly Assembled Cartridge Cartridge Tool Shield Cup Art A 04344_AB 2 Take the Removal Tool off the back of t...

Страница 114: ...r the locking ring Art A 04066_AC O Rings Cat No 9 3027 Cat No 9 3026 Cat No 9 3025 Torch Head Cat No 9 9041 CAUTION Use only Thermal Dynamics No 9 4893 O Ring Lubricant Christo Lube MCG 129 with this...

Страница 115: ...he consumables and Cartridge Handle all parts carefully to avoid damage which may affect torch performance NOTE For 200 Amp consumables when replacing the shield retainer or the shield cup assemble th...

Страница 116: ...Cap Protrudes 0 063 0 083 1 6 2 1 mm Electrode Plasma Gas Distributor Tip Shield Gas Distributor Shield Cap O Ring on Tip 1 Stack Parts 2 Press Cartridge onto Stacked Parts 4 Check Shield Cap Protrusi...

Страница 117: ...e torch head with a wire brush Apply oxygen compatible lubricant supplied with the torch to the threads Torch Head O Ring Torch Head Art A 07202 0 063 0 083 1 6 2 1 mm Protrusion Installing Assembled...

Страница 118: ...New or Used Are Parts fully assembled into the Torch Unsure Disassembly fully and re assemble the Torch Properly See Installation Manual Replace Torch Head Is the Torch Damaged Replace Consumable Car...

Страница 119: ...Manual 0 4805 Auto Cut 200 7 7 TORCH MAINTENANCE Insert sec 8 tab here discard this sheet...

Страница 120: ......

Страница 121: ...25 23 Jumper to 15 28 22 26 24 Sol 1 29 27 30 31 32 36 37 POWER SUPPLY J55 Art A 04848 ARC STARTER GAS CONTROL MODULE J56 1 Jumper to 2 2 Jumper to 1 15 Jumper to 23 14 Run Set Sw 16 17 33 Ground 34 3...

Страница 122: ...Power Supply J59 to Arc Starter Gas Control Console J58 3 9 120 VAC RET 5 1 Jumpered to 4 6 7 120 VAC 8 10 13 14 11 12 Art A 04849 2 Ground POWER SUPPLY J59 ARC STARTER GAS CONTROL MODULE J58 3 5 4 1...

Страница 123: ...15 R70 R2 U27 R79 C2 U5 R91 D11 R51 C25 R89 R18 R8 C51 D3 D13 U28 1 C8 R31 R40 C34 R85 R38 C48 D7 R92 R57 R7 R4 C1 R36 1 2 1 SW4 C9 R3 R62 R63 U17 R13 160 U14 1 40 120 80 R27 C31 R59 R55 R32 U13 1 C45...

Страница 124: ...SOLATED PILOT PILOT R56 R56 DEMAND DEMAND CUT CUT DEMAND DEMAND ARC V ARC V R114 R114 PILOT V PILOT V CC POT CC POT D3 D3 TP8 TP8 R26 R26 K7 GAS ON K7 GAS ON C34 C34 U19 U19 L2 L2 C27 C27 R29 R29 C83...

Страница 125: ...Manual 0 4805 Auto Cut 200 A 5 APPENDIX This page is blank intentionally...

Страница 126: ...10 Remote Analog Current Control 0 10V TB1 11 TB1 12 TB2 1 Hold Start TB2 2 Hold Start TB2 3 Preflow On TB2 4 Preflow On TB2 5 TB2 6 Pilot On Relay Contacts NO TB2 7 TB2 8 Pilot On Relay Contacts NO T...

Страница 127: ...functionsareonlyavailableonTB1 2 2 SW6 on CCM I O PCB selects OK to Move for isolated contact closure or DC Volts 15 18V at 100ma When set for contacts OK to Move circuit is rated for 120 VAC 28 VDC 1...

Страница 128: ...W8 2 ON up Hold Start input Normally open close to hold start Circuit rating 10 ma 20VDC Delays pilot ignition gas preflow continues Used for synchronizing starts when multiple plasma supplies are use...

Страница 129: ...12 2 ON 30 1 SW12 3 ON 40 1 SW12 4 ON ARC V 2 1 3 5 4 6 SW6 Active LOW Logic Input 16 to 18 VDC isolated PSR OK to Move ARC V Active LOW Logic Input 100K 3 6 SW12 3 4 5 SW12 4 1 8 SW12 1 2 7 SW12 2 2...

Страница 130: ...ma Divided Arc V Arc V through 100K Arc V through 100K 10 11 10 11 Divided Arc V Remote Analog Current Control Remote Analog Current Control Relay DCV Contact or 1A DCV 120 VAC 15 18 VDC or 28 VDC up...

Страница 131: ...Manual 0 4805 Auto Cut 200 A 11 APPENDIX This Page Intentionally Blank...

Страница 132: ...12 12 13 13 14 14 WORK WORK WORK WORK T1 T1 11X16 11X16 T1 T1 11X16 11X16 1 2 3 4 J55 J55 J55 J55 1 2 3 4 5 6 7 8 9 10 10 11 11 12 12 13 13 14 14 15 15 16 16 17 17 18 18 19 19 20 20 21 21 22 22 23 23...

Страница 133: ...Thursday February 03 2005 C DWG No DWG No Sheet Sheet of of Supersedes Supersedes Scale Scale Date Date Drawn Drawn References References Date Date By By Revisions Revisions Rev Rev PCB No PCB No Ass...

Страница 134: ...60 230 230 208 230 460 VAC 3 Phase CN6 100A INVERTER MODULE 2 bottom same as 1 D2 Sht 2 RIBBON CABLE SIGNALS CN6 16 Ckt Ribbon Cable 2 4 I_REF Scaled Cut Demand 5 PS_START Start 6 REDUNDANT_START Star...

Страница 135: ...er Tuesday October 03 2006 08 11 44 Thermal Dynamics D RAS PCB 8 WK 5687 RC RF CAPS HALL SENSOR HALL SENSOR PILOT REG CHOPPER PCB1 WK 5750 BIAS POWER PILOT REGULATOR CHOPPER OVER_TEMP P_DEM P_Iref P_E...

Страница 136: ...ELCOL_0 CN12 CN12 1 2 CN2 CN2 1 2 TP4 TP4 CN20 CN20 1 2 3 CN3 CN3 1 2 3 D2 E STOP_PS D2 E STOP_PS V GND SIG FL1 FLOW_TURBINE_PULSE V GND SIG FL1 FLOW_TURBINE_PULSE R B G T1 T1 460 220 0 13 0 100 0 200...

Страница 137: ...4 603 298 5711 150 200 Amp Power Supply 208 230 460V Chopper Tuesday October 03 2006 08 11 44 Thermal Dynamics D KEY PLUG CN11 34 CKT CN10 26 CKT J36 34 CKT J35 26 CKT RIBBON CABLE TEST SOCKET RIBBON...

Страница 138: ...460 230 230 208 230 460 VAC 3 Phase CN6 100A INVERTER MODULE 2 bottom same as 1 D2 Sht 2 RIBBON CABLE SIGNALS CN6 16 Ckt Ribbon Cable 2 4 I_REF Scaled Cut Demand 5 PS_START Start 6 REDUNDANT_START Sta...

Страница 139: ...RC RF CAPS HALL SENSOR HALL SENSOR PILOT REG CHOPPER PCB1 WK 5750 BIAS POWER PILOT REGULATOR CHOPPER OVER_TEMP P_DEM P_Iref P_Enable P_ena PILOT REG CHOPPER PCB2 WK 5754 I_DET I_SE PILOT CURRENT SIGNA...

Страница 140: ...CN2 1 2 TP4 TP4 CN20 CN20 1 2 3 CN3 CN3 1 2 3 D2 E STOP_PS D2 E STOP_PS V GND SIG FL1 FLOW_TURBINE_PULSE V GND SIG FL1 FLOW_TURBINE_PULSE R B G T1 T1 460 220 0 13 0 100 0 200 0 110 0 120 0_ 24 0__ 24...

Страница 141: ...Supply 208 230 460V Resistor Tuesday October 03 2006 08 11 44 Thermal Dynamics D KEY PLUG CN11 34 CKT CN10 26 CKT J36 34 CKT J35 26 CKT RIBBON CABLE TEST SOCKET RIBBON CABLE TEST SOCKET E2 E2 E4 F4 P...

Страница 142: ...CB 400 400 VAC 3 Phase CN6 100A INVERTER MODULE 2 bottom same as 1 D2 Sht 2 RIBBON CABLE SIGNALS CN6 16 Ckt Ribbon Cable 2 4 I_REF Scaled Cut Demand 5 PS_START Start 6 REDUNDANT_START Start2 8 INV_REA...

Страница 143: ...October 03 2006 08 11 44 Thermal Dynamics D RAS PCB 8 WK 5687 RC RF CAPS HALL SENSOR HALL SENSOR PILOT REG CHOPPER PCB1 WK 5750 BIAS POWER PILOT REGULATOR CHOPPER OVER_TEMP P_DEM P_Iref P_Enable P_en...

Страница 144: ...2 1 2 TP4 TP4 CN20 CN20 1 2 3 CN3 CN3 1 2 3 C P4 C P4 D2 E STOP_PS D2 E STOP_PS V GND SIG FL1 FLOW_TURBINE_PULSE V GND SIG FL1 FLOW_TURBINE_PULSE R B G T1 TX1P8S T1 TX1P8S 400 200 0 13 0 100 0 200 0 1...

Страница 145: ...5711 150 200 A Power Supply 400V CCC Chopper Tuesday October 03 2006 08 11 44 Thermal Dynamics D KEY PLUG CN11 34 CKT CN10 26 CKT J36 34 CKT J35 26 CKT RIBBON CABLE TEST SOCKET RIBBON CABLE TEST SOCK...

Страница 146: ...N CABLE SIGNALS CN6 16 Ckt Ribbon Cable 2 4 I_REF Scaled Cut Demand 5 PS_START Start 6 REDUNDANT_START Start2 8 INV_READY 9 PS_START disabled by Input_NG 12 OCR 13 PS_START disabled by OCR 14 TEMP_ERR...

Страница 147: ...REG CHOPPER PCB1 WK 5750 BIAS POWER PILOT REGULATOR CHOPPER OVER_TEMP P_DEM P_Iref P_Enable P_ena PILOT REG CHOPPER PCB2 WK 5754 I_DET I_SE PILOT CURRENT SIGNAL WORK CURRENT SIGNAL PILOT ENABLE PILOT...

Страница 148: ...2 1 2 TP4 TP4 CN20 CN20 1 2 3 CN3 CN3 1 2 3 C P4 C P4 D2 E STOP_PS D2 E STOP_PS V GND SIG FL1 FLOW_TURBINE_PULSE V GND SIG FL1 FLOW_TURBINE_PULSE R B G T1 TX1P8S T1 TX1P8S 400 200 0 13 0 100 0 200 0 1...

Страница 149: ...5711 150 200A Power Supply 400V CE Chopper Tuesday October 03 2006 08 11 44 Thermal Dynamics D KEY PLUG CN11 34 CKT CN10 26 CKT J36 34 CKT J35 26 CKT RIBBON CABLE TEST SOCKET RIBBON CABLE TEST SOCKET...

Страница 150: ...ON CABLE SIGNALS CN6 16 Ckt Ribbon Cable 2 4 I_REF Scaled Cut Demand 5 PS_START Start 6 REDUNDANT_START Start2 8 INV_READY 9 PS_START disabled by Input_NG 12 OCR 13 PS_START disabled by OCR 14 TEMP_ER...

Страница 151: ...able P_ena PILOT REG CHOPPER PCB2 WK 5754 I_DET I_SE PILOT CURRENT SIGNAL WORK CURRENT SIGNAL PILOT ENABLE PILOT DEMAND HCT1 Hall Current Sensor Pilot B8 Sht 1 HCT2 Hall Current Sensor Work C9 Sht 1 L...

Страница 152: ...PREFLOW D28 CNC_PREFLOW 1 2 RY3 RY3 1 2 D26 HOLD_START D26 HOLD_START C P7 C P7 CN14 CN14 1 2 D12 STATUS CODE D12 STATUS CODE C P4 C P4 CN20 CN20 1 2 3 RY4 RY4 C P2 C P2 D23 CNC_START D23 CNC_START CN...

Страница 153: ...400V CE Resistor Tuesday October 03 2006 08 11 44 Thermal Dynamics D KEY PLUG CN11 34 CKT CN10 26 CKT J36 34 CKT J35 26 CKT RIBBON CABLE TEST SOCKET RIBBON CABLE TEST SOCKET E2 E2 E4 F4 POWER SUPPLY...

Страница 154: ...ER PCB 600 600 VAC 3 Phase CN6 100A INVERTER MODULE 2 bottom same as 1 D2 Sht 2 RIBBON CABLE SIGNALS CN6 16 Ckt Ribbon Cable 2 4 I_REF Scaled Cut Demand 5 PS_START Start 6 REDUNDANT_START Start2 8 INV...

Страница 155: ...cs D RAS PCB 8 WK 5687 RC RF CAPS HALL SENSOR HALL SENSOR PILOT REG CHOPPER PCB1 WK 5750 BIAS POWER PILOT REGULATOR CHOPPER OVER_TEMP P_DEM P_Iref P_Enable P_ena PILOT REG CHOPPER PCB2 WK 5754 I_DET I...

Страница 156: ...CN2 1 2 TP4 TP4 CN20 CN20 1 2 3 CN3 CN3 1 2 3 C P4 C P4 D2 E STOP_PS D2 E STOP_PS V GND SIG FL1 FLOW_TURBINE_PULSE V GND SIG FL1 FLOW_TURBINE_PULSE R B G T1 T1 600 220 0 13 0 100 0 200 0 110 0 120 0_...

Страница 157: ...5711 150 200 A Power Supply 600V CSA Chopper Tuesday October 03 2006 08 11 44 Thermal Dynamics D KEY PLUG CN11 34 CKT CN10 26 CKT J36 34 CKT J35 26 CKT RIBBON CABLE TEST SOCKET RIBBON CABLE TEST SOCK...

Страница 158: ...sion control starting with AA 01 Oct 10 2006 AB 01 Added inverter module part numbers for 400V 400V CE and 600V Jan 10 2007 AC 01 Updated Error codes in section 4 and added notice to update to Firmwar...

Страница 159: ...This Page Intentionally Blank...

Страница 160: ...Indonesia Customer Care Ph 6221 8990 6095 Fax 6221 8990 6096 Rawang Malaysia Customer Care Ph 603 6092 2988 Fax 603 6092 1085 Melbourne Australia Australia Customer Care Ph 1300 654 674 tollfree Ph 61...

Отзывы: