Manual No. 0-4805 Auto-Cut 200
3-15
INSTALLATION
3.10 Set Switches for Type 2 Command-Control Module
Remove the power supply right side. Set switches on the CCM (Command-Control Module) per the illustrations.
Switch settings and connection details are provided in the Appendix.
CAUTION
Printed circuit boards in the Command - Control Module are static - sensitive. Discharge any built-up static
charges in your body or surroundings before touching the printed circuit boards.
SW1
SW3
SW4
SW5
SW8
3
4
1
2
3
4
1
2
1
2
1
2
1
2
1
2
SW-1-1: Auto Pilot Restart. 1 = ON = Auto Pilot Function enabled.
1 = OFF = Auto Pilot Function disabled (Factory default setting).
SW-1-2: Pilot Delay 2 = OFF, 3 = OFF, 4 = OFF: 0 Seconds (Factory default setting).
SW-1-3: Pilot Delay 2 = ON, 3 = OFF, 4 = OFF: 0.1 Seconds
SW-1-4: Pilot Delay 2 = OFF, 3 = ON, 4 = OFF: 0.2 Seconds
2 = ON, 3 = ON, 4 = OFF: 0.4 Seconds
2 = OFF, 3 = OFF, 4 = ON: 0.8 Seconds
2 = ON, 3 = OFF, 4 = ON: 1.0 Seconds
2 = OFF, 3 = ON, 4 = ON: 1.5 Seconds
2 = ON, 3 = ON, 4 = ON: 2.0 Seconds
SW-4: Postflow Time 1 = OFF, 2 = OFF: 10 Seconds (Factory default setting).
1 = ON, 2 = OFF: 20 Seconds
1 = OFF, 2 = ON: 5 Seconds
1 = ON, 2 = ON: 0 Seconds
SW-5-1: Tip Saver
Reserved for Factory use.
SW-5-2: Off Plate
Reserved for Factory use.
SW 8-1: Pilot Time 1 = OFF = Short (85 ms.) (Factory default setting).
1 = ON = Long (3 s.)
O
N
O
N
Active only when
SW-1-1 is set to O N.
Art # A-06869_AB
Future Use
SW-3: Gas Preflow Time 1 = Off, 2 = OFF: 2 seconds
1 = ON, 2 = OFF: 4 seconds
1 = OFF, 2 = ON: 6 seconds
1 = ON, 2 = ON: 8 seconds
* SW 8-3 is reserved for
Factory use prior to
Firmware V3.5
SW 8-2: Remote Current 1 = OFF = Disabled (Factory default setting).
1 = ON = (Remote Analog Current Control)
*SW 8-3: Auto Transfer Retry1 = OFF = Enabled Up to 3 tries (Factory default setting).
1 = ON = Disabled
SW 8-4:
Reserved for Factory use.
Содержание VICTOR 200 AUTO-CUT
Страница 2: ...Thispageintentionallyblank...
Страница 4: ...Thispageintentionallyblank...
Страница 6: ...Thispageintentionallyblank...
Страница 10: ...Thispageintentionallyblank...
Страница 11: ...INSERT TABLE OF CONTENTS TAB HERE DISCARD THIS SHEET...
Страница 12: ...Thispageintentionallyblank...
Страница 16: ...TABLE OF CONTENTS...
Страница 17: ...Insert Section 1 tab here Discard this sheet...
Страница 18: ......
Страница 27: ...Insert Section 2 tab here Discard this sheet...
Страница 28: ......
Страница 37: ...Manual No 0 4805 Auto Cut 200 2 9 SPECIFICATIONS Insert Sec 3 tab here Discard this sheet...
Страница 38: ......
Страница 66: ...This Page Intentionally Blank...
Страница 67: ...Insert Sec 4 tab here Discard this sheet...
Страница 68: ......
Страница 80: ......
Страница 81: ...Insert sec 5 tab here discard this sheet...
Страница 82: ......
Страница 88: ...Manual No 0 4805 Auto Cut 200 5 6 MAINTENANCE This page is blank intentionally...
Страница 89: ...Manual No 0 4805 Auto Cut 200 5 7 MAINTENANCE Insert Sec 6 tab here discard this sheet...
Страница 90: ......
Страница 110: ...Manual No 0 4805 Auto Cut 200 6 20 Parts List This Page Intentionally Blank...
Страница 111: ...Manual No 0 4805 Auto Cut 200 6 21 Parts List Insert Sec 7 tab here discard this sheet...
Страница 112: ......
Страница 119: ...Manual 0 4805 Auto Cut 200 7 7 TORCH MAINTENANCE Insert sec 8 tab here discard this sheet...
Страница 120: ......
Страница 125: ...Manual 0 4805 Auto Cut 200 A 5 APPENDIX This page is blank intentionally...
Страница 131: ...Manual 0 4805 Auto Cut 200 A 11 APPENDIX This Page Intentionally Blank...
Страница 159: ...This Page Intentionally Blank...