ULTRA-CUT 400 XT
Manual 0-5275
SPECIFICATIONS
2-1
SECTION 2: SPECIFICATIONS
2.01 General Description Of The System
A typical Ultra-Cut XT™system configuration includes:
• One Power Supply
• Remote Arc Starter
• Gas Control Module
• Torch Valve Assembly
• Precision Plasma Cutting Torch
• Set Of Connecting Leads
• Torch Spare Parts Kit
The components are connected at installation.
2.02 Plasma Power Supply
The power supply provides the necessary current for cutting operations. The power supply also monitors system performance,
and cools and circulates the liquid coolant for the torch and leads.
2.03 Remote Arc Starter
This unit produces a temporary HF pulse to start the pilot arc. The pilot arc creates a path for the main arc to transfer to the work.
When the main arc is established, the pilot arc shuts off.
2.04 Gas Control Module
This module allows remote setting of gas selection, pressures, and flows together with setting of cutting current.
2.05 Precision Plasma Cutting Torch
The torch delivers the controlled current to the work through the main arc, causing the metal to be cut.
2.06 Specifications & Electrical Requirements
400 Amp System
Ultra-Cut 400 XT™ Specifications & Design Features
Max OCV (U0)
425 vdc
Minimum Output Current
5 Amps
Max Output Current
400 Amps
Output Voltage
60 - 200 vdc
Duty Cycle Rating
100% @ 400A, 200V, (80kW),
Ambient Temperature
for Duty Cycle Rating
104F° (40°C)
Operating range
14°F to 122°F (-10°C to + 50°C)
Power Factor
0.94 @ 400 A DC Output
Cooling
Coolant and Forced Air (Class F)
Ultra-Cut 400 XT™ Power Supply
Input
Power Input Current
Suggested Sizes (See Note)
Voltage
Freq.
3-Ph
3-Ph
Fuse (Amps)
Wire (AWG) Wire (mm
2
)
(Volts)
(Hz)
(kVA)
(Amps)
3-Ph
3-Ph
3-Ph
480
50/60
93
114
175
#3
35
Содержание Ultra-Cut 300 XT
Страница 6: ...This Page Intentionally Blank...
Страница 10: ...TABLE OF CONTENTS This Page Intentionally Blank...
Страница 15: ...ULTRA CUT 400 XT Manual 0 5275 SAFETY INSTRUCTIONS 1 5 This Page Intentionally Blank...
Страница 88: ...ULTRA CUT 400 XT OPERATION Manual 0 5275 This Page Intentionally Blank...
Страница 106: ...ULTRA CUT 400 XT REPLACEMENT PARTS Manual 0 5275 This Page Intentionally Blank...
Страница 114: ...ULTRA CUT 400 XT TORCH INFORMATION Manual 0 5275 This Page Intentionally Blank...
Страница 130: ...ULTRA CUT 400 XT APPENDIX Manual 0 5275 APPENDIX 8 CCM CPU PCB Layout Test Point Test Point Art A 11675_AB...
Страница 132: ...ULTRA CUT 400 XT APPENDIX Manual 0 5275 APPENDIX 9 CCM I O PCB Layout Test Point Test Point Art A 11676_AC...
Страница 134: ...ULTRA CUT 400 XT APPENDIX Manual 0 5275 APPENDIX 10 Pilot PCB Layout Art A 11677 Test Point Test Point...
Страница 136: ...ULTRA CUT 400 XT APPENDIX Manual 0 5275 APPENDIX 11 Relay and Interface PCB Layout Test Point Test Point Art A 11678_AB...
Страница 138: ...ULTRA CUT 400 XT APPENDIX Manual 0 5275 APPENDIX 12 Display PCB Layout Test Point Test Point Art A 11679...
Страница 139: ...ULTRA CUT 400 XT Manual 0 5275 APPENDIX A 25 Display PCB Test Points TP1GND TP2 5VDC TP3 24VDC...
Страница 140: ...ULTRA CUT 400 XT APPENDIX Manual 0 5275 APPENDIX 13 System Bias PCB Layout Test Point Test Point Art A 11680...
Страница 142: ...ULTRA CUT 400 XT APPENDIX Manual 0 5275 APPENDIX 14 Main Inverter Bottom PCB Layout Test Point Test Point Art A11681_AB...
Страница 144: ...ULTRA CUT 400 XT APPENDIX Manual 0 5275 APPENDIX 15 Main Inverter Top PCB Layout Test Point Test Point Art A11682_AB...
Страница 146: ...ULTRA CUT 400 XT APPENDIX Manual 0 5275 APPENDIX 16 Control and Fault PCB Layout Test Point Test Point Art A11683_AB...
Страница 148: ...ULTRA CUT 400 XT APPENDIX Manual 0 5275 APPENDIX 17 Cap Bias Bottom PCB Layout Art A 11685_AB...
Страница 149: ...ULTRA CUT 400 XT Manual 0 5275 APPENDIX A 35 APPENDIX 18 Cap Bias Top PCB Layout Art A 11686_AB...
Страница 150: ...ULTRA CUT 400 XT APPENDIX Manual 0 5275 APPENDIX 19 Suppressor PCB Layout Art A 11684_AB...
Страница 201: ...ULTRA CUT 400 XT Manual 0 5275 APPENDIX A 87 This Page Intentionally Blank...
Страница 213: ......