Manual 0-2746
3-1
INSTALLATION
SECTION 3:
INSTALLATION
3.01 Introduction
NOTE
Depending on how the system was ordered, some
Power Supply Options may already be installed.
If option(s) have been factory installed some of the
instructions may not apply. It is recommended
that all subsections be read for general informa-
tion.
This section describes installation of the Power Supply
and connecting the Torch.
These instructions apply to the Power Supply only; in-
stallation procedures for the Torch, Options, and Acces-
sories are given in Manuals specifically provided for those
units.
The complete installation consists of:
1. Site selection
2. Unpacking
3. Connections to Power Supply
a.
Input power
b. Gas
c.
Work cable
d. Torch Leads
4. Grounding
5. Operator training
3.02 Site Selection
Select a clean, dry location with good ventilation and ad-
equate working space around all components.
NOTE
Review Important Safety Precautions (Section 1)
to be sure that the selected location meets all safety
requirements.
The power supply is fan cooled by air flow through the
front panel to the rear panel. Air flow must not be ob-
structed. Provide at least 2 feet / 0.61 m in the rear and
at least 6 inches / 150 mm on each side for clearance.
Provide sufficient clearance in front of the unit to allow
access to the front panel controls / minimum 6 inches or
150 mm.
CAUTION
Operation without proper air flow will inhibit
proper cooling and reduce duty cycle.
3.03 Unpacking
Each component of the system is packaged and protected
with a carton and packing material to prevent damage
during shipping.
l. Unpack each item and remove any packing material.
NOTE
The Cutting Spare Parts Kit is shipped in the Torch
Leads Storage Area on the side of the Power Sup-
ply.
2. Locate the packing list(s) and use the list to identify
and account for each item.
3. Inspect each item for possible shipping damage. If
damage is evident, contact your distributor and / or
shipping company before proceeding with system in-
stallation.
3.04 Lifting Options
WARNINGS
Do not touch live electrical parts.
Disconnect input power conductors from de - en-
ergized supply line before moving unit.
HANDLE
is not for mechanical lifting.
FALLING EQUIPMENT
can cause serious per-
sonal injury and equipment damage.
This unit is equipped with one handle mounted onto the
top of the enclosure for hand carrying purposes.
• Lift unit with the handle on top of the enclosure.
• Only persons of adequate physical strength should
lift the unit.
• Use hand cart, optional Cart, or similar device of
adequate capacity.
• If using a fork lift vehicle, place and secure unit on
a proper skid before transporting.
• This unit has a handle mounted on top of the enclo-
sure for hand lifting only. Be sure unit is lifted and
transported safely and securely.
Содержание PakMaster 75XL Plus
Страница 2: ......
Страница 6: ......
Страница 12: ...GENERAL INFORMATION 1 6 May 14 2002...
Страница 26: ...INSTALLATION 3 12 Manual 0 2746...
Страница 45: ...Manual 0 2746 A 5 APPENDIX This page left blank...
Страница 46: ...APPENDIX A 6 Manual 0 2746 A 02503 APPENDIX 5 SYSTEM SCHEMATIC...
Страница 47: ...Manual 0 2746 A 7 APPENDIX A 02503...
Страница 48: ......