Manual 0-2728
A-5
APPENDIX
J3-10
+12 vdc
J3-11
Active Low Signal for AC Indicator on Front Panel (J14-5)
J3-12
Active Low Signal for GAS Indicator on Front Panel (J14-6)
J3-13
Active Low Signal for TEMP Indicator on Front Panel (J14-7)
J3-14
Active Low Signal for DC Indicator on Front Panel (J14-8)
J3-15
Not Used
J3-16
Not Used
J4-1
36 VAC (b) from Gate Driver PC Board (J9-1)
J4-2
36 VAC (a) to Gate Drive PC Board (J9-2)
J4-3
36 VAC (a) from Gate Drive PC Board (J9-3)
J4-4
36 VAC (b) to Gate Drive PC Board (J9-4)
J4-5
36 VAC CT Return/PC Board Common
J4-6
Transfer Mod Enable Return
J4-7
36 VAC CT Return/PC Board Common
J4-8
Active Low Transfer Mod Enable Signal
J4-9
Return for Temp Switch
J4-10
Active Low Over Temp Signal
J4-11
Return for Master Enable Signal
J4-12
Active Low Master Enable Signal
J4-13
Return for Pilot Enable
J4-14
Active Low Pilot Enable Signal
J4-15
Return for PSR Signal
J4-16
Active Low PSR Signal
J4-17
Return for Demand Signal
J4-18
Demand Signal
J4-19
Return for Demand Signal
J5-1
36 VAC (b) to CD PC Board
J5-2
36 VAC CT Return to CD PC Board
J5-3
36 VAC (a) to CD PC Board
J5-4
Active Low CD Enable Signal
J5-5
CD Enable Return
J5-6
Active Low Pilot Signal to Pilot/Output Board
J5-7
Pilot Signal Return
J5-8
Active Low Torch Switch Signal
J5-9
Torch Switch Return
J5-10
Active Low Torch Sw Signal to LATCH Sw
J5-11
Not Used
J5-12
PS+
J5-13
Not Used
J5-14
Drag Sensing Signal Voltage (Tip Volts +)
J5-15
Not Used
J5-16
PS-
J5-17
36 VAC (a) to Pilot Output Board
J5-18
36 VAC (b) to Pilot Output Board
J5-19
36 VAC CT Return to Pilot/Output Board (Opt Remote)
J5-20
Active Low ENABLE Signal
J5-21
Return for Optional Remote Enable Jumper
J95-1
Not Used
J95-2
Not Used
J96-1
115VAC to Fans M3 & M4
J96-2
115VAC to Fans M1 & M2
J96-3
115VAC Fan Rtn for M3 & M4
J96-4
115VAC Fan Rtn for M1 & M2
J17-1
Not Used
J17-2
Not Used
J17-3
115 VAC to Plasma Solenoid
J17-4
115 VAC to Inrush Cont
J17-5
115 VAC to Motor Cont
J17-6
Not Used
J17-7
115 VAC Return Sec. Solenoid
J17-8
115 VAC Return Inrush Cont
J17-9
115 VAC Return Motor Cont
J17-10 Not Used
J17-11 OK-To-Move (Isolated Contact Closure)
J17-12 OK-To-Move (Isolated Contact Closure)
J99-1
Active Low Coolant Flow Switch Signal
J99-2
Not Used
J99-3
Coolant Flow Switch Return
J99-4
Not Used
J99-5
Active Low Torch Sw Signal from LATCH Sw
J99-6
Active Low CSR Signal From Current Sense Board
J99-7
Return
J99-8
+12 vdc
TP1
Logic Ground
TP2
+18 vdc - Unregulated
TP3
+18 vdc - Unregulated
TP4
+10 vdc
TP5
Demand Signal to Gate PC Board
TP6
+12 vdc
TP7
Drag CRT
TP8
(-) DC Sense
TP9
Active Low PSR Signal
TP10
Active Low CSR Signal
TP11
Current Control Demand (Pot Wiper)
D26
Torch Switch Enable Indicator
D25
CD Enable Indicator
D65
CSR Indicator
D47
AC OK Indicator
D31
Drag On Indicator
Содержание PAK Master 150XL
Страница 2: ......
Страница 6: ......
Страница 16: ...INTRODUCTION 2 2 Manual 0 2728...
Страница 61: ...Manual 0 2728 6 5 PARTS LISTS 7 1 2 6 3 A 02580 8 5 4 10 9 9...
Страница 65: ...Manual 0 2728 6 9 PARTS LISTS 1 3 4 2 A 02278 7 8 5 6 23x4274 11 13 12 16 17 18 19 14 15 20 9 10 21...
Страница 67: ...Manual 0 2728 6 11 PARTS LISTS 8 9 10 4 14 5 6 5 8 9 10 4 14 12 11 2 13 7 3 3 1 20 19 15 17 16 18 21 A 02387...
Страница 86: ...APPENDIX A 18 Manual 0 2728 APPENDIX 14 SYSTEM SCHEMATIC Unit Rev AQ or Earlier A 02329...
Страница 88: ...APPENDIX A 20 Manual 0 2728 APPENDIX 14 SYSTEM SCHEMATIC Unit Rev AR or Later A 03054...
Страница 90: ......