APPENDIX
APPENDIX 1: INPUT WIRING REQUIREMENTS
NOTES
Refer to Local and National Codes or local authority having jurisdiction for proper wiring requirements.
Cable size is de-rated based on the Duty Cycle of the equipment.
The suggested sizes are based on flexible power cable with power plug installations. For hard-wired installations
refer to local or national codes.
Cable conductor temperature used is 167° F (75° C).
An energy limiting fuse UL Class RK-1 (examples: BUSS LPS/LPN-RK or Gould-Shawmut AZK-A6K) should be
used to minimize damage to Plasma Cutting, Welding or power distribution equipment.
NEVER
use replaceable element fuses like UL Class H, or "one-time" fuses like UL Class K5.
Input
Power Input
Current
Suggested Sizes (See Notes)
Voltage
Freq.
3-Ph
3-Ph
Fuse (Amps)
Wire (mm
2
)
(Volts)
(Hz)
(kVA)
(Amps)
3-Ph
3-Ph
380
50/60
29.0
44
60
10
415
50/60
29.5
41
60
10
Line Voltages with Suggested Circuit Protection and Wire Sizes
Based on National Electric Code and Canadian Electrical Code
Содержание PAK Master 150XL
Страница 2: ......
Страница 6: ......
Страница 16: ...INTRODUCTION 2 2 Manual 0 2728...
Страница 61: ...Manual 0 2728 6 5 PARTS LISTS 7 1 2 6 3 A 02580 8 5 4 10 9 9...
Страница 65: ...Manual 0 2728 6 9 PARTS LISTS 1 3 4 2 A 02278 7 8 5 6 23x4274 11 13 12 16 17 18 19 14 15 20 9 10 21...
Страница 67: ...Manual 0 2728 6 11 PARTS LISTS 8 9 10 4 14 5 6 5 8 9 10 4 14 12 11 2 13 7 3 3 1 20 19 15 17 16 18 21 A 02387...
Страница 86: ...APPENDIX A 18 Manual 0 2728 APPENDIX 14 SYSTEM SCHEMATIC Unit Rev AQ or Earlier A 02329...
Страница 88: ...APPENDIX A 20 Manual 0 2728 APPENDIX 14 SYSTEM SCHEMATIC Unit Rev AR or Later A 03054...
Страница 90: ......