CUTMASTER A60
APPENDIX
A-12
Manual 0-4982
APPENDIX 7: RAW ARC VOLTAGE
If raw arc voltage is necessary for the torch height control, the customer must supply an 18 AWG (1.0 mm2), single
pair, unshielded cable rated for 300V or greater. All work must be performed following applicable local and national
codes.
1. Disconnect the power from the power supply.
2. Remove the screws that attach the power supply cover to the chassis. Remove the cover.
3. Route the cable through the customer supplied strain relief at the rear of the power supply.
Art # A-10286
Cut out for cable
4. On the main board use insulated type 1/4-inch ring lug terminal ends to connect to –Vout1 (- polarity) and
WORK 1 (+ polarity).
!
WARNING
The raw arc voltage can exceed 350VDC !!!!
-V OUT 1
WORK 1
J10
-V OUT 1
WORK 1
Art # A-10287
Содержание cutmaster A60
Страница 4: ...This Page Intentionally Blank...
Страница 8: ...TABLE OF CONTENTS...
Страница 16: ...CUTMASTER A60 GENERAL INFORMATION 16 Manual 0 4982 This Page Intentionally Blank...
Страница 24: ...CUTMASTER A60 INTRODUCTION 2T 4 Manual 0 4982 This Page Intentionally Blank...
Страница 36: ...CUTMASTER A60 OPERATION 4 4 Manual 0 4982 This Page Intentionally Blank...
Страница 45: ...CUTMASTER A60 Manual 0 4982 4T 9 OPERATION This Page Intentionally Blank...
Страница 84: ...CUTMASTER A60 OPERATION 4T 48 Manual 0 4982 This Page Intentionally Blank...
Страница 105: ...CUTMASTER A60 Manual 0 4982 5 21 SERVICE This Page Intentionally Blank...
Страница 108: ...CUTMASTER A60 SERVICE 5 24 Manual 0 4982 This Page Intentionally Blank...
Страница 113: ...CUTMASTER A60 Manual 0 4982 6 3 PARTS LIST Intentionally Blank...
Страница 121: ...CUTMASTER A60 Manual 0 4982 6 11 PARTS LIST Intentionally Blank...
Страница 124: ...CUTMASTER A60 PARTS LIST 6 14 Manual 0 4982 Intentionally Blank...
Страница 139: ...CUTMASTER A60 Manual 0 4982 A 7 APPENDIX Intentionally Blank...
Страница 147: ...This Page Intentionally Blank...