SERVICE
D. Initial Set up Conditions
This section is to help isolate the defective circuit
before troubleshooting, identify symptoms, and test
the unit for proper operation. Follow the instructions
as given to identify the possible symptom(s) and the
defective circuit. After repairs are complete, run the
following tests again to verify that the unit is fully
operational.
1. Connect gas supply to rear of Power Supply.
2. Turn ON gas supply and set operating pressure
per pressure setting label on power supply.
3. Set the Power Supply controls as follows:
• ON/OFF SWITCH to OFF position
• Turn FUNCTION CONTROL SWITCH to SET
position
• CURRENT CONTROL POTENTIOMETER to
MAXIMUM position, fully clockwise.
E. Main Input and Internal Power Test
1. Connect Primary Line power to the unit.
2. Turn the ON/OFF SWITCH ( SW1) to ON position
and observe the following:
• Software version is displayed (See section 5.04
Fault Indicators)
After approx. three (3) seconds
• Inrush relay on PCB 1 energizes, starting pre-
charging of working capacitors.
• W1 energizes
• AC and GAS Indicators come ON
• Gas flows
• Fans turn ON
3. Adjust the pressure regulator to set the gas pres-
sure as specified in charts.
STANDOFF
CutMaster A-60 Gas Pressure Settings
Leads
Length
SL60
(Hand Torch)
SL100
(Mechanized Torch)
Up to 25'
(7.6 m)
75 psi
5.2 bar
70 psi
4.8 bar
Each additional
25' (7.6 m)
Add 5 psi
0.4 bar
Add 5 psi
0.4 bar
DRAG
CutMaster A-60 Gas Pressure Settings
Leads
Length
SL60
(Hand Torch)
SL100
(Mechanized Torch)
Up to 25'
(7.6 m)
80 psi
5.5 bar
75 psi
5.2 bar
Each additional
25' (7.6 m)
Add 5 psi
0.4 bar
Add 5 psi
0.4 bar
4. Turn FUNCTION CONTROL SWITCH to RUN
position
• Solenoid turns OFF, gas stops flowing (pres
-
sure display may increase slightly when gas
is not flowing)
This completes the Main Input and Internal Power Test.
If the above are all correct then proceed to the next section
"F. Pilot Arc Test". If the unit does not function as stated
above, then note the symptom and proceed to Section
"5.07, Main Input and Internal Power Problems".
F. Pilot Arc Test
1. Activate CNC Start signal, close Remote Pendant
switch or depress the Torch switch to establish a
pilot arc and note the following
• Gas solenoid opens
• Gas flows
• Depending on torch attached, after as much as
two seconds the gas solenoid closes and gas
stops flowing momentarily, then gas solenoid
re-opens and gas resumes flowing
• DC LED comes ON
• Pilot arc is established
2. Remove CNC start signal or release the Remote
Pendant or Torch switch
• Gas continues to flow
• DC LED goes OFF
After 20 second post flow time
• Gas solenoid closes
• Gas flow stops
This completes the Pilot Arc Test. If the above are all
correct then proceed to the next section "G, Main Arc
and Controls Test". If the unit does not function as stated
above, then note the symptom and proceed to Section
"5.08, Pilot Arc Problems".
Содержание cutmaster A60
Страница 4: ...This Page Intentionally Blank...
Страница 8: ...TABLE OF CONTENTS...
Страница 16: ...CUTMASTER A60 GENERAL INFORMATION 16 Manual 0 4982 This Page Intentionally Blank...
Страница 24: ...CUTMASTER A60 INTRODUCTION 2T 4 Manual 0 4982 This Page Intentionally Blank...
Страница 36: ...CUTMASTER A60 OPERATION 4 4 Manual 0 4982 This Page Intentionally Blank...
Страница 45: ...CUTMASTER A60 Manual 0 4982 4T 9 OPERATION This Page Intentionally Blank...
Страница 84: ...CUTMASTER A60 OPERATION 4T 48 Manual 0 4982 This Page Intentionally Blank...
Страница 105: ...CUTMASTER A60 Manual 0 4982 5 21 SERVICE This Page Intentionally Blank...
Страница 108: ...CUTMASTER A60 SERVICE 5 24 Manual 0 4982 This Page Intentionally Blank...
Страница 113: ...CUTMASTER A60 Manual 0 4982 6 3 PARTS LIST Intentionally Blank...
Страница 121: ...CUTMASTER A60 Manual 0 4982 6 11 PARTS LIST Intentionally Blank...
Страница 124: ...CUTMASTER A60 PARTS LIST 6 14 Manual 0 4982 Intentionally Blank...
Страница 139: ...CUTMASTER A60 Manual 0 4982 A 7 APPENDIX Intentionally Blank...
Страница 147: ...This Page Intentionally Blank...