INSTALLATION
3-4
Manual 0-2868
D. Installing Optional Air Filter Kits
Additional filtering is recommended when using air from
a compressor to insure that moisture and debris from the
supply hose does not enter the torch. Although the Regu-
lator/Filter Assembly has its own filter, the optional fil-
ter kits are recommended for improved filtering.
1. Optional Single-Stage Air Filter Kit
This in-line air filter for use on compressed air shop
systems is highly effective at removing moisture and
particulate matter from the air stream to at least 0.85
microns.
Art # A-03000
Regulator/Filter
Assembly
Inlet Port
Bowl
1/4 NPT Hose Fitting
1/4" (6 mm) Gas Supply Hose
Hose Clamp
Optional Single-Stage Filter Installation
NOTE
For a secure seal, apply thread sealant to the fitting
threads, according to manufacturer's instructions.
Do Not use Teflon tape as a thread sealer as small
particles of the tape may break off and block the
small gas passages in the torch. Connect the gas
supply as follows:
a. Attach the Single-Stage Filter Hose to the Regu-
lator/Filter Assembly inlet port as shown.
b. Attach the Single-Stage Filter Assembly to the
filter hose.
c. Use customer-supplied fittings to connect the
gas line to the Filter. Typical fittings are shown
as examples. Install the fittings and tighten.
2. Optional Two-Stage Air Filter Kit
This optional two-stage air line filter is also for use
on compressed air shop systems. Filter removes mois-
ture and contaminants to at least 5 microns.
Connect the gas supply as follows:
a. Attach the Two Stage Filter bracket to the back
of the power supply.
NOTE
For a secure seal, apply thread sealant to the fit-
ting threads according to manufacturer's instruc-
tions. Do Not use Teflon tape as a thread sealer as
small particles of the tape may break off and block
the small gas passages in the torch.
b. Connect the two stage filter outlet hose to the
inlet port of the Regulator/Filter Assembly.
c. Use customer-supplied fittings to connect the
gas line to the Filter. Typical fittings are shown
as examples. Install the fittings and tighten.
Art # A-03004
Regulator/Filter
Assembly
Hose
Clamp
1/4 NPT
Hose Fitting
1/4" (6 mm) Gas
Supply Hose)
2-Stage Filter
Inlet Port (IN)
Outlet Port
(OUT)
Regulator Inlet Port
Two Stage
Filter
Assembly
Optional Two-Stage Filter Installation
Содержание CutMaster 75
Страница 1: ...Operating Manual Plasma Cutting Power Supply CutMaster 75 March 22 2004 Manual No 0 2868 A 02991...
Страница 2: ......
Страница 6: ......
Страница 12: ...GENERAL INFORMATION 1 6 January 27 2004...
Страница 28: ...OPERATION 4 4 Manual 0 2868...
Страница 41: ...Manual 0 2868 A 5 APPENDIX Notes...
Страница 48: ......