INSTALLATION
14
Manual 0-2470
Choosing a Location
CAUTION
NOTE
3.02 CHOOSING A LOCATION
Select a clean, dry location with good ventilation and adequate
working space around all components.
The power supply is cooled by air flow through the rear panel.
Air flow must not be obstructed. Provide at least 2 feet (0.61 m) of
clearance in the rear. Provide at least 6 inches (0.15 m) clearance
on each side. Provide sufficient clearance in front of the unit to
allow access to front panel controls (minimum 6 in or 0.15 m).
Operation without proper air flow will inhibit proper cooling and
reduce duty cycle.
Review Important Safety Precautions at the front of this Manual
to be sure that the selected location meets all safety requirements.