Manual 0-2470
25
INSTALLATION
3.08 GAS CONNECTIONS (continued)
7. Set the high pressure regulator to 100 psi and adjust the unit
regulator for the desired 70 psi.
Always open the high pressure cylinder valve slowly to prevent
damage to the unit gas regulator.
An air line filter (ordered separately) is required when using air
from a compressor to insure that moisture and debris from the
supply hose does not enter the torch.
The LeMan two stage air line filter kit is recommended for most
applications. Follow the installation instructions for this kit on
page 18.
Air Line Filter Kit - Two Stage ................................... Cat. No. 7-3340
CAUTION
Using Shop Air
Figure 3-H Gas Connections
Quick Disconnect
Fitting (1/4 NPT)
Rear Panel Fitting
(1/4 NPT)
Quick Disconnect
Coupling (1/4 NPT
to #6 Hose)
Supply Hose from
Source (#6 Hose)
A-00758