CUTMASTER 42
INTRODUCTION 2-2 Manual 0-5141
Art# A-09333_AC
26lb / 11.8kg
7" (177mm)
18.5" (469.9mm)
9" (228.6mm)
CUTMASTER
®
42
120V 15A
120V 20A
230V 20A
A
24
40
20
20
30
27
Figure 2-1 Power Supply Dimensions & Weight
NOTE
Weight includes torch & leads, input power cord, and work cable with clamp.
CAUTION
Provide clearance for proper air flow through the power supply. Operation without proper air flow will
inhibit proper cooling and reduce duty cycle.
2.03 Input Wiring Specifications
CUTMASTER 42 Input Power Requirements
Input
Power Input
Current Input
Current Input
Suggested Sizes (See Note)
Voltage
Freq.
(kVA)
Max (Amps)
Ieff (Amps)
Fuse (Amps)
(Volts-AC)
(Hz)
1-Ph
1-Ph
1-Ph
1-Ph
120
50/60
3.3
27.5
15
25
208
50/60
5.0
24
15.4
23
230
50/60
5.0
21.4
13.5
20
240
50/60
5.0
20.8
13
20
Line Voltages with Suggested Circuit Protection
Motor start fuses or thermal circuit breakers are recommended for this application. Check local requirements for your situation
in this regard.
NOTE
Refer to Local and National Codes or local authority having jurisdiction for proper wiring requirements.
Cable size is de-rated based on the Duty Cycle of the equipment.
The suggested sizes are based on flexible power cable with power plug installations.
Cable conductor temperature used is 167° F (75° C).