TROUBLE SHOOTING
6-6
Manual 0-4751
Testing of diode modules requires a digital volt/ohmmeter that has a diode test scale. Remember that even if the
diode module checks good, it may still be bad. If in doubt, replace the diode module.
1.
Remove AC power. Refer to Appendix 3 Wiring diagram.
2.
Locate the IGBT diode module to be tested.
3.
Remove P5 from IGBT module.
4.
Set digital volt/ohmmeter to diode test scale.
5.
Connect the volt/ohmmeter positive lead to the anode (+) of the diode and the negative lead to the cathode (-) of
the diode for forward bias testing (refer to following figure). A properly functioning diode will conduct in the
forward bias direction and indicate between 0.3 to 0.9 volts.
0.75
VR COM
A
Art # A-00307
Anode
Cathode
Forward Bias
Diode Conducting
+
_
Diode Test Symbol
Testing Diode Forward Bias
Содержание 35C
Страница 2: ......
Страница 4: ......
Страница 12: ...GENERAL INFORMATION 1 6 Manual 0 4751 This Page Left Blank...
Страница 16: ...Installation 3 2 Manual 0 4751 This Page Left Blank...
Страница 20: ...Operation 4 4 Manual 0 4751 This Page Left Blank...
Страница 22: ...Maintenance 5 2 Manual 0 4751 This Page Left Blank...
Страница 32: ...TROUBLE SHOOTING 6 10 Manual 0 4751 This Page Left Blank...
Страница 35: ...Manual 0 4751 7 3 PARTS LIST Art A 07771 1 2 3 4 5 6 7 8 9 Art A 07772 10 11 12 13 14 15 16 17 18 19 20 21...
Страница 36: ...PARTS LIST 7 4 Manual 0 4751 Art A 07773 22 23 24 25 26 27 28 29 30...
Страница 37: ...Manual 0 4751 7 5 PARTS LIST This Page Left Blank...
Страница 39: ...Manual 0 4751 7 7 PARTS LIST Art A 07061 1 7 8 6 6 15 9 2 10 3 4 5 11 12 13 14...
Страница 40: ...PARTS LIST 7 8 Manual 0 4751 This Page Left Blank...
Страница 48: ...APPENDIX A 8 Manual 0 4751 This Page Left Blank...