background image

!

WARNINGS

Read and understand this entire Manual and your employer’s safety practices before install-
ing, operating, or servicing the equipment.

While the information contained in this Manual represents the Manufacturer's best judge-
ment, the Manufacturer assumes no liability for its use.

Plasma Cutting Power Supply
Drag-Gun Plus 35C
PCH 42 Torch
Operating Manual Number 0-4750

Covered under U.S. Patents

Published by:
Thermadyne Industries, Inc.
82 Benning Street
West Lebanon, New Hampshire, USA  03784
(603) 298-5711

www.thermal-dynamics.com

© Copyright 2005, 2006, 2007 by
Thermadyne Industries, Inc.

All rights reserved.

Reproduction of this work, in whole or in part, without written permission of the publisher is prohibited.

The publisher does not assume and hereby disclaims any liability to any party for any loss or damage
caused by any error or omission in this Manual, whether such error results from negligence, accident,
or any other cause.

Printed in the United States of America

Publication Date: October 18, 2007

Record the following information for Warranty purposes:

Where Purchased:____________________________________

Purchase Date:_______________________________________

Power Supply Serial #:________________________________

Torch Serial #:________________________________________

Содержание 35C DRAG-GUN PLUS

Страница 1: ...PLASMA PLASMA CUTTING SYSTEM 35C DRAG GUN PLUS Operating Manual Rev AB Date October 18 2007 Manual 0 4750 Operating Features...

Страница 2: ...please take the time to read the entire manual especially the Safety Precautions They will help you to avoid potential hazards that may exist when working with this product YOU ARE IN GOOD COMPANY Th...

Страница 3: ...yright 2005 2006 2007 by Thermadyne Industries Inc All rights reserved Reproduction of this work in whole or in part without written permission of the publisher is prohibited The publisher does not as...

Страница 4: ......

Страница 5: ...N 2 1 2 02 GENERAL SPECIFICATION 2 1 2 03 Features 2 1 2 04 Torch Specifications 2 2 2 05 System Contents 2 2 2 06 Transporting Methods 2 2 SECTION 3 INSTALLATION 3 1 3 01 Site Selection 3 1 3 02 Elec...

Страница 6: ...mium Mercury Arsenic Cobalt Nickel Barium Copper Selenium Beryllium Lead Silver Cadmium Manganese Vanadium Always read the Material Safety Data Sheets MSDS that should be supplied with the material yo...

Страница 7: ...Washington D C 20402 2 ANSI Standard Z49 1 SAFETY IN WELDING AND CUTTING obtainable from the American Welding Society 550 N W LeJeune Rd Miami FL 33126 3 NIOSH SAFETY AND HEALTH IN ARC WELDING AND GA...

Страница 8: ...de l arc de plasma d pendent du genre de m tal utilis des rev tements se trouvant sur le m tal et des diff rents proc d s Vous devez prendre soin lorsque vous coupez ou soudez tout m tal pouvant cont...

Страница 9: ...h par moiceau de travail BRUIT Le bruit peut provoquer une perte permanente de l ou e Les proc d s de soudage l arc de plasma peuvent provoquer des niveaux sonores sup rieurs aux limites normalement a...

Страница 10: ...ion des Normes Canadiennes Standards Sales 178 Rexdale Boulevard Rexdale Ontario Canada M9W 1R3 13 Livret NWSA BIBLIOGRAPHIE SUR LA S CURIT DU SOUDAGE disponible aupr s de l Association Nationale de F...

Страница 11: ...standard C22 2 No 60 for Arc Welding Equipment CENELEC EN50199 EMC Product Standard for Arc Welding Equipment IEC EN 60974 1 EN50192 EN50078 Arc Welding Equipment Part 1 Welding Power Supplies IEC EN...

Страница 12: ...ips electrodes shield cups o rings starter cartridges gas distributors fuses filters 2 Equipment that has been modified by an unauthorized party improperly installed improperly operated or misused bas...

Страница 13: ...DRAG GUN PLUS 35C GENERAL INFORMATION 1 8 Manual 0 4750 This Page Left Blank...

Страница 14: ...8 9 mm Maximum Cutting Capacity 1 2 12mm Dimension W D H 10 5 x15 5 x11 267 mm x 394 mm x 279 mm Duty cycle 104 F 40 C Ambient NOTE Refer to Local and National Codes or local au thority having jurisd...

Страница 15: ...H 142 lpm Direct Contact Hazard For operation with exposed tip the recommended standoff height is 1 8 3 8 3 9 mm Plasma Power Supply used with Drag Gun Plus PCH 42 Torch Ratings 2 05 System Contents D...

Страница 16: ...ry power source fuse and any extension cords used must conform to local electrical code and the recommended circuit protection and wir ing requirements as specified in Section 2 3 03 Torch Make sure t...

Страница 17: ...Installation 3 2 Manual 0 4750 This Page Left Blank...

Страница 18: ...te the power supply NOTE It is possible to have enough air pressure to oper ate the power supply but not enough air flow to operate the torch Torch Switch Latch Indicator This indicator lights when th...

Страница 19: ...to the work piece or cutting table Work Cable And Clamp Art A 04389 D Torch Operation Wear gloves and protective goggles Do not place bare hand on work piece 1 For drag cutting keep the torch in conta...

Страница 20: ...0 900 29 0 725 Drag Gun Plus 1 8 3mm 3 8 9 5mm 15 0 375 12 0 300 Drag Gun Plus 1 8 3mm 7 16 11mm 10 0 250 8 0 200 Drag Gun Plus 1 8 3mm 1 2 12mm 8 200 7 175 Recommended Travel Speed Maximum Travel Sp...

Страница 21: ...Switch Off and then On again 3 Switch may be faulty a Return to an authorized service center for repair B Primary power switch is on but the cooling fan does not work 1 No power incorrect power to fa...

Страница 22: ...cutting table Work Cable And Clamp Art A 04389 3 Current sensor or PWM PCB faulty a Return to an authorized service center for repair F Air flows continuously and torch switch latch button doesn t wor...

Страница 23: ...orch Switch On Compressor Starts and Air Flows at Torch Turn Air Set Switch Off Red Air Indicator Pilot Arc goes out Release Torch Switch Primary Input Power Switch Off or Unplugged Green Power Indica...

Страница 24: ...ct power and air Lay unit on its side Remove two screws and access plate Pilot Power Supply Adapter Connections Negative Plasma Lead Art A 04695 DETAIL To Power Supply Adapter Pilot Negative Plasma Le...

Страница 25: ...A C1 C2 C1 No 30279014 Rev AA GND OU_1 VCC OU_1 Current Sensor Inductor Current Sensor CN1 C1 No 30279015 Rev AA White White No 30276003 Rev AC Black Tempertature Switch Green White White AIR CHECK Ye...

Страница 26: ...APPENDIX 6 4 Manual 0 4750 DRAG GUN PLUS 35C This Page Intentionally Blank...

Страница 27: ...i PR 200052 Telephone 86 21 69171135 Fax 86 21 69171139 Thermadyne Asia Sdn Bhd Lot 151 Jalan Industri 3 5A Rawang Integrated Industrial Park Jln Batu Arang 48000 Rawang Selangor Darul Ehsan West Mala...

Страница 28: ...Corporate Headquarters 16052 Swingley Ridge Road Suite 300 St Louis MO 63017 Telephone 636 728 3000 Email TDCSales Thermadyne com www thermadyne com...

Отзывы: