Manual 0-5056
A-11
APPENDIX
CNC Input / Output Descriptions
E-Stop input— Requires closed connection rated for
35ma. @ 20VDC
for unit to operate. Factory installed jumper between
TB1-1&2 must be removing when connecting user supplied E-Stop circuit.
4
Start/Stop input—Switch (momentary or sustained) rating 35ma. @ 20 VDC
Start / Stop circuit configurations. Momentary Start / Stop (Latched) is only available at TB1.
MOMENTARY START / STOP
START / STOP
TB1-6
TB1-5
TB1-4
SUSTAINED START / STOP
START
STOP
TB1-5
TB1-6
Divided Arc Voltage output
— Arc Voltage signal is isolated from plasma supply, however (-) is common with other
isolated CNC signals. Max Divided Arc Voltage signal level depends on actual arc voltage times divide ratio however
can not exceed approximately 12 V.
3
Analog Current Control input
— Analog Current Control includes analog isolation module, separate isolation
module not usually required however it’s low input is common with the other isolated CNC inputs. Scaling of Analog
Current Control input is 0V = 0A, 10V. = MAX output and is linear in between. However MIN output is 10A. User is
responsible for setting correct analog voltage to maintain at least 10A output. To use Analog Current Control on the
I/O PCB set SW 11 to down position and on the CPU PCB set SW8-2 ON (up).
Hold Start input
—Normally open, close to hold start. Circuit rating 10 ma. @ 20VDC. Delays pilot ignition, gas
preflow continues. Used for synchronizing starts when multiple plasma supplies are used on same cutting table. User
supplies circuit to keep Hold Start inputs active until all torches have found height.
Preflow On input
— Normally open, close to start preflow prior to normal START signal. Circuit rating 10 ma. @
20VDC. Torch Height Controls (THC) normally issue START signal to plasma supply after torch height has been
found. Then the plasma takes 1-2 seconds (or more) to perform preflow before igniting pilot. Some THCs have an
output that can start preflow early during height finding saving 1-2 seconds on each cut.
Pilot On output
– Relay contacts rated 1A @ 120 VAC / 28 VDC. Contacts close when pilot on. Can be wired parallel
with Ok to Move contacts to start machine motion when pilot established. Used when starting over holes. Starting over
holes requires setting SW8-1 ON (up) on the CPU PCB for extended pilot time. Using extended pilot time to start over
holes or for cutting over holes will reduce parts life.
OK to Move output
— Active when cutting arc is established, arc is transferred. Used to signal cutting table to start
X-Y motion. Relay contacts rated 1A @ 120 VAC or 28 VDC when SW6 set for contacts. When SW6 is set for DCV, output
supplies 15-18 VDC @ 100 ma. May be wired parallel with Pilot On to start cutting machine motion as soon as pilot
established.
Содержание 200 ULTRA-CUT
Страница 4: ...Thispageintentionallyblank ...
Страница 8: ......
Страница 80: ...Manual No 0 5056 4 16 OPERATION This page intentionally blank ...
Страница 110: ...Manual No 0 5056 6 28 Power Supply Parts List Intentionally Blank ...
Страница 116: ...TORCH INFORMATION 7 6 Manual 0 5056 This page is blank intentionally ...
Страница 129: ...Manual 0 5056 A 13 APPENDIX This page intentionally blank ...