Manual No. 0-5056
4-13
OPERATION
Status
Code
5-1
CANBUS Failure to
Acknowledge fault.
If GCM 1000, Basic ID signal missing; Other gas controls, Fiber
disconnected or broken, Transceiver (what fiber plugs into) fault, replace
Gas control PCB or CCM
CANBUS Off due to
excessive data errors;
CANBUS data error warning
.
Errors increasing, will soon
fault.
5-4
CCM Message not sent
Dirt on fiber ends or in connectors, blow out with clean dry air; fiber not
locked into connector; sharp bends in fiber; fiber defective; CANBUS
hardware error (CCM or Gas Control PCB)
6-1
CCM Analog Voltage Error
Replace CCM
6-2
CCM ADC or DAC error
Replace CCM
Torch coolant tube broken or missing;
CCM fault, replace CCM
6-4
CCM Data Memory error
Replace CCM
Status Code Key (cond)
Message
Cause/Remedy
5-2
Dirt on fiber ends or in connectors, blow out with clean dry air; fiber not
locked into connector; sharp bends in fiber; fiber defective;
5-3
Dirt on fiber ends or in connectors, blow out with clean dry air; fiber not
locked into connector; sharp bends in fiber; fiber defective;
6-3
Coolant Flow too High error
,
flow > 2.7 gal/min
Содержание 200 ULTRA-CUT
Страница 4: ...Thispageintentionallyblank ...
Страница 8: ......
Страница 80: ...Manual No 0 5056 4 16 OPERATION This page intentionally blank ...
Страница 110: ...Manual No 0 5056 6 28 Power Supply Parts List Intentionally Blank ...
Страница 116: ...TORCH INFORMATION 7 6 Manual 0 5056 This page is blank intentionally ...
Страница 129: ...Manual 0 5056 A 13 APPENDIX This page intentionally blank ...