TITAN 1280 USER MANUAL
18
7-1-2 LVDS_H
LVDS_H digital video includes one clock signal (LVDS_CLK) and four data signals
(LVDS_DATA1, LVDS_DATA2, LVDS_DATA3 and LVDS_DATA4). It is convenient to
be parsed by mainstream encode/decode chip.
LVDS_H digital video can be enabled or disabled by control command. When
it is enabled, original data (RAW), temperature data (TMP), data after image
processing(DRC, DRC_Gray, DRC_Color) can be selected.
When the original data (RAW) and temperature data (TMP) are selected, function
of polarity selection, digital zoom, digital detail enhancement, digital filter and
imaging denoising and temperature display are not supportable.
When data after image processing (DRC) is selected, function of digital zoom
and temperature display are not supportable.
LVDS_H Clock Frequency
Model
LVDS_CLK
Titan 1280
78.75MHz
Sync Code
H0
H1
H2
H3
H4
H5
H6
H7
BLANK LINE
3FFF
0000
0000
2AC0
3FFF
0000
0000
2D80
VALID LINE
3FFF
0000
0000
2000
3FFF
0000
0000
2740