Страница 1: ...SWITCHING THE UNIT ON IMPORTANT SAFETY INFORMATION INSIDE Shown with a 13 mm lens 855 W Cardinal Dr Suite A Beaumont TX 77705 Phone 409 861 0788 Toll Free 866 861 0788 Thermal Camera cores fall under...

Страница 2: ...EUROPA SERIES USER MANUAL 2 Revision History 04 2022 001 Document created...

Страница 3: ...ns 6 2 9 Training 7 Safety Information 8 Technical Specifications 10 Lens Options and Model Numbers 14 5 1 Europa 640 Models 14 5 2 Europa 380 Models 15 Structure 16 6 1 Pin Layout 16 6 2 Pin Connecto...

Страница 4: ...written permission of Thermal Camera The documentation must not in whole or part be copied photocopied reproduced translated or transmitted to any electronic medium or machine readable form without p...

Страница 5: ...heeled bin symbol indicates that waste electrical and electronic equipment should not be discarded together with unseparated household waste but must be collected separately All local authorities have...

Страница 6: ...terface options It can be used for a wide range of applications Environment of use UAV UAS integrations handheld and head mounted equipment multi spectral systems industrial monitoring security applic...

Страница 7: ...EUROPA SERIES USER MANUAL 7 2 9 Training To read about infrared training visit https infraredtraininginstitute com...

Страница 8: ...ly the device may be damaged Do not put holes in the device with objects Damage to the device may occur Do not hit the device with a hammer or apply strong impacts or electric shocks to it Damage to t...

Страница 9: ...nough for the condensation to evaporate Keep device out of reach of children This product is a precise electronic device that must be handled with care during use storage and transportation to prevent...

Страница 10: ...ity NETD 50 mK 0 05 C at 25 C 77 F Frame Rate 30 Hz PAL or 50 Hz NTSC 1 Dimensions without lens 26 mm x 26 mm x 22 mm L x W x D 0 5 mm 1 02 x 1 02 x 0 87 L x W x H 0 02 2 Power 4V 6V DC 1 3W 3 4V 6V D...

Страница 11: ...t 3 5V 18V DC 4 8 bit or 14 bit LVCMOS digital video is supported only on the 70 pin connector module 5 This function is only available in analog video and digital BT 656 Europa 640 Europa 380 Palette...

Страница 12: ...voltage Under voltage Reverse Connection Weight without lens 21 g 0 75 oz 3 g 0 11 oz Zoom 1 0X 8 0X continuous zoom 6 Interface RS 232 UART 3 3 V Expansion Board Available Video Analog 1 channel PAL...

Страница 13: ...out connector board 4 Wattage is based on tests without extension boards Typical working voltage is 5V DC Expansion components support 3 5V 18V DC 5 8 bit or 14 bit LVCMOS digital video is supported o...

Страница 14: ...17 25 mm 1 0 Athermal 17 14 0 480 mrad ICIEuropa640P X 12 ICIEuropa640C 0 12 ICIEuropa640SL 0 12 35 mm 1 0 Athermal 12 5 10 0 340 mrad ICIEuropa640P X 08 ICIEuropa640C 0 08 ICIEuropa640SL 0 08 55 mm...

Страница 15: ...CIEuropa380SL 0 44 5 8 mm 1 2 Athermal 44 33 2 060 mrad ICIEuropa380P X 28 ICIEuropa380C 0 28 ICIEuropa380SL 0 28 9 1 mm 1 2 Athermal 28 21 1 310 mrad ICIEuropa380P X 20 ICIEuropa380C 0 20 ICIEuropa38...

Страница 16: ...n the connector Users can adopt the Hirose 70 Pin DF40HC 3 0 70DS 0 4V 51 to implement the connection between the thermal camera and user expansion boards 6 Structure 6 2 Pin Connector Interface Descr...

Страница 17: ...35 DV11 Data 36 DV10 Data 37 DV13 Data MSB 14 bit 38 DV12 Data 24 DV14 Data Data 23 DV15 Data MSB 16 bit Data MSB BT 1120 39 Line_Valid Line valid signal Line valid signal 40 Frame_Valid Frame valid s...

Страница 18: ...ending and receiving 3 GND and VGND are shorted internally PLEASE READ AND UNDERSTAND THE TABLES BEFORE SWITCHING THE UNIT ON NO Name Type Description 47 LVDS_CLK Output LVDS_H VCCIO 2 5V Clock Signal...

Страница 19: ...ded into 10 bit and 14 bit When RAW data or temperature TMP data are produced the data bits are 14 bits namely DV 13 0 where DV0 is LSB and DV13 is the MSB When the user selects the data after the out...

Страница 20: ...ts output image processing DRC data CDS_2 is only available for radio metric Europa devices i e Europa 380 and Europa 640 C SL Series devices cannot utilize CDS_2 CDS_2 digital video contains 1 Clock...

Страница 21: ...ck Frequency Europa C 380 Europa SL 380 22 500 MHz Europa C 640 Europa SL 640 33 750 MHz Europa 380 11 250 MHz Europa 640 22 500 MHz CDS_2 Clock Frequency Model Clock Frequency Europa 380 22 5 MHz Eur...

Страница 22: ...ER MANUAL 22 Sync Code H0 H1 H2 H3 H4 H5 H6 H7 BLANK LINE 3FFF 0000 0000 2AC0 3FFF 0000 0000 2D80 VALID LINE 3FFF 0000 0000 2000 3FFF 0000 0000 2740 PLEASE READ AND UNDERSTAND THE TABLES BEFORE SWITCH...

Страница 23: ...pin DF52 20S 0 8H connector Molex 20 pin 52745 2097 connector Coming Soon Power input 3 5 18 VDC typical 12 VDC RS232 RS422 LVDS_H digital video Analog video 4 keys DF56C 30S 0 3V Coming Soon Power in...

Страница 24: ...replace the cloth and repeat operation 9 2 Disinfecting the Camera Surface Do not use corrosive cleaning solutions on the optical glass components Do not get the electronics wet It is recommended to d...

Страница 25: ...ntists inspectors and operators in space power companies medical pulp and paper food industry research and development and various process industries Thank you for your dedicated and continued support...