background image

Product Summary

The MotionViewer IMV200 is a wireless, indoor motion activated camera 
designed for use in a Videofied™ security system. The camera includes the fol-
lowing features:

>

 Lithium batteries for long life

>

 Color Day / B&W night

>

 Wide angle lens

>

 Infrared LEDs for night illumination

>

 Standard motion coverage lens (30 ft./9 m distance)

>

 Dual tamper function provides detection of both wall and  cover tamper.

>

 Transmits check-in/status signal every 8 minutes

Installation Guidelines

For an easier installation, programming and RF testing should be done to check for good 
communication between the control panel and all system devices before mounting. 

Install the detector and other system devices in the following order:

>

 Programming / RF Testing: Program detector and all other devices into the  

 

control panel and test RF communication at each intended device location to  

 

the control panel.

>

 Mounting: Mount detector at the tested location.

Mounting Rules

Use proper tools and hardware.

Mount indoors in a temperature controlled environment.

Mount camera 2.0 to 2.3 m (6.6 to 7.5 ft.) from the floor.

Respect Top and Bottom side of the Motion Viewer

When possible, mount in a wall corner in order to aim at a complete    

 room

Mount detector on an outside wall, aimed at area to protect.

Do not aim detector at windows, especially those that let in direct    

  sunlight,  or at heat sources such as lamps, fireplaces, radiators, and  
  heating vents.

Do not aim detector at moving objects such as curtains, fans or  

 

 animals.

Do not cover the Fresnel lens

Corner 
Mounting 
Holes

Corner Mounting

Flat Wall Mounting

Flat Wall 
Mounting 
Holes

www.videofied.com

P R O D U C T   I N S T A L L A T I O N   S H E E T

Indoor MotionViewer IMV200

Made by RSI VIDEO TECHNOLOGIES

2225-IMVIS January - 2013

Содержание IMV200

Страница 1: ...ices into the control panel and test RF communication at each intended device location to the control panel Mounting Mount detector at the tested location Mounting Rules Use proper tools and hardware Mount indoors in a temperature controlled environment Mount camera 2 0 to 2 3 m 6 6 to 7 5 ft from the floor Respect Top and Bottom side of the Motion Viewer When possible mount in a wall corner in or...

Страница 2: ...ess YES By default all devices in area 1 will be subject to the entry and exit delays 11 The display shows NAME LOCATION Enter an appropriate device name up to 16 characters The name of the device should describe its intended mounting location or zone Press YES The display will show the device number and name for your verification 12 Mount the IMV on the wall Follow the mounting rules on page 1 Ho...

Страница 3: ...V200 I N S T A L L A T I O N D A T A S H E E T www videofied com 0 2m 4m 6m 8m 10m 12m 5m 4m 3m 2m 1m 0 1m 2m 3m 4m 5m PIR angle 90 Camera angle 110 Horizontal distance Floor level 0m 1m 4m 8m 12m Mounting at 2m00 Mounting at 2m10 Mounting at 2m30 1m00 Detection Diagrams ...

Страница 4: ...50 1 2006 A11 2009 A1 2010 EN300220 1 V2 4 1 EN300220 2 V2 4 1 NF EN50130 4 1995 A1 1998 A2 2003 NF EN50130 5 1998 Class II NF EN50131 2 2 2009 Grade 2 NF EN50131 5 3 2005 Grade 2 NF EN50131 6 2008 Grade 2 Type C Pending certifications Europe CE EN50131 Grade 2 Netherlands NCP Singapore IDA South Africa ICASA EN Security notes FR Notes de sécurité DE Hinweise zur Sicherheit English Remove battery ...

Отзывы: