28
16.
SELECTING WELD CABLES SIZES
Total Cable (Copper) Lenght in Weld circuit Not Exceeding
100 ft. (30 m)
or Less
150 ft.
(45 m)
200 ft.
(60 m)
250 ft.
(70 m)
300 ft.
(90 m)
350 ft.
(105 m)
400 ft.
(120 m)
10 To 60%
Duty Cycle
60 Thru 100%
Duty Cycle
10 Thru 100% Duty Cycle
100
4
4
4
3
2
1/0
1/0
1/0
150
3
3
2
1
1/0
2/0
3/0
3/0
200
3
2
1
1/0
2/0
3/0
4/0
4/0
250
2
1
1/0
2/0
3/0
4/0
2-2/0
2-2/0
300
1
1/0
2/0
3/0
4/0
2-2/0
2-3/0
2-3/0
350
1/0
2/0
3/0
4/0
2-2/0
2-3/0
2-3/0
2-4/0
400
1/0
2/0
3/0
4/0
2-2/0
2-3/0
2-4/0
2-4/0
500
2/0
3/0
4/0
2-2/0
2-3/0
2-4/0
3-3/0
3-3/0
600
3/0
4/0
2-2/0
2-3/0
2-4/0
3-3/0
3-4/0
3-4/0
Wels cables size (AWG) is based on either a 4 volts or less drop or a current density of more than