![Thermal Arc ARCMASTER 200 TS Скачать руководство пользователя страница 70](http://html1.mh-extra.com/html/thermal-arc/arcmaster-200-ts/arcmaster-200-ts_service-manual_1103173070.webp)
200TS
12
MAINTENANCE
12 – 14
3.7 PCB7 (WK-5460) and Q3A-Q4C “Primary IGBT”
1) Remove the Side Panel. [See section “11.1-1”]
2) Remove the four screws and two IGBT Spring Clips. Remove the cables from edge holder.
3) Disconnect the connector CN1 on the PCB6. Cut the lead of the Q3-Q4C.
Remember to install new Silicone Rubber Sheets where silicone compound (Shinetsu Silicone G-747 or
equivalent) was spread when reinstalling the PCB7. Spread the silicone compound on IGBT.
1
1
2
3
2
CN1
1
1
Содержание ARCMASTER 200 TS
Страница 2: ......
Страница 16: ...1 10 May 22 2006 ARCMASTER 200 TS...
Страница 34: ...200TS 7 ROUTINE MAINTENANCE 7 2 PAGE LEFT INTENTIONALLY BLANK...
Страница 42: ...200TS 10 POWER SOURCE ERROR CODE 10 2 PAGE LEFT INTENTIONALLY BLANK...
Страница 93: ......