![Thermal Arc ARCMASTER 200 TS Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/thermal-arc/arcmaster-200-ts/arcmaster-200-ts_service-manual_1103173024.webp)
200TS
3
INSTALLATION
3 – 4
9
Specifications
Thermal Arc continuously strives to produce the
best product possible and therefore reserves the
right to change, improve or revise the specifica-
tions or design of this or any product without prior
notice. Such updates or changes do not entitle the
buyer of equipment previously sold or shipped to
the corresponding changes, updates, improve-
ments or replacement of such items.
The values specified in the table above are optimal
values, your values may differ. Individual equip-
ment may differ from the above specifications due
to in part, but not exclusively, to any one or more of
the following; variations or changes in manufac-
tured components, installation location and condi-
tions and local power grid supply conditions.
Parameter
200TS
Rated Output
115VAC
230VAC
Amperes
85A
200A
Volts
13V
18V
Duty Cycle
100%
20%
Duty Cycle
TIG
200A / 18V @ 20% 230VAC
130A / 15V @ 60% 230VAC
100A / 14V @ 100% 230VAC
85A / 13V @ 100%
115VAC
STICK
160A / 27V @ 35% 230VAC
130A / 25V @ 60%
230VAC
100A / 24V @ 100% 230VAC
85A / 23V @ 100%
115VAC
Output Current
Range
TIG
1 - 200 (230V), 1 - 85 (115V)
STICK
1 - 160 (230V), 1 - 85 (115V)
Open Circuit Voltage
57V
Dimensions
Width
5.12" (130mm)
Height
10.24" (260mm)
Length
12.60" (320mm)
Weight
17.63 lb. 8.0 kg
Output@Rated Load
115V
230V
Output Amperes
85A
160A
Output Volts
23V
27V
Duty Cycle
100%
35%
KVA
4.4
8.7
KW
2.4
5.2
Output@No Load
KVA
0.2
KW
0.1
Input Volts Single
Phase
Amperage Draw
@Rated Load
No Load
230V
40
1.0