SAFETY 

 

 

USER’S MANUAL 

Page 

7/22

 

 

 
If electromagnetic disturbances are detected, then it shall be the responsibility of the user of the arc welding 
equipment to resolve the situation with the technical assistance of the manufacturer. In some cases this remedial 
action may be as simple as earthing the welding circuit, see Note. In other cases it could involve constructing an 
electromagnetic screen enclosing the welding power source and the work complete with associated input filters. In 
all cases electromagnetic disturbances shall be reduced to the point, where they are no longer troublesome. 
 
NOTE - The welding circuit may or may not be earthed for safety reasons. Changing the earthing arrangements 
should only be authorised by a person who is competent to assess whether the changes will increase the risk of 
injury, e.g. by allowing parallel welding current return paths, which may damage the earth circuits of other 
equipment. 
Further guidance is given in IEC 62081 "Arc welding equipment - Installation and use" (under consideration). 
 
 

1.2.1.

 

ASSESSMENT OF AREA 

 

Before installing arc welding equipment the user shall make an assessment of potential electromagnetic problems 
in the surrounding area. The following shall be taken into account : 
 
a) Other supply cables, control cables, signalling and telephone cables, above, below and adjacent to the arc 
welding equipment; 
 
b) Radio and television transmitters and receivers; 
 
c) Computer and other control equipment; 
 
d) Safety critical equipment, e.g. guarding of industrial equipment, 
 
e) The health of the people around, e.g. the use of pacemakers and hearing aids; 
 
f) Equipment used for calibration or measurement; 
 
g) The immunity of other equipment in the environment. The user shall ensure that other equipment being used in 
the environment is compatible. This may require additional protection measures; 
 
h) The time of day that welding or other activities are to be carried out. 

 
 

 

The size of the surrounding area to be considered will depend on the structure of the building and other activities 
that are taking place. The surrounding area may extend beyond the boundaries of the premises. 
 
 

1.2.2.

 

METHODS OF REDUCING EMISSIONS 

 

1.2.2.1. 

Public supply system 

Arc welding equipment should be connected to the public supply system according to the manufacturer’s 
recommendations. If interference occurs, it may be necessary to take additional precautions such as filtering of the 
public supply system. Consideration should be given to shielding the supply cable of permanently installed arc 
welding equipment, in metallic conduit or equivalent. Shielding should be electrically continuous throughout its 
length. The shielding should be connected to the welding power source so that good electrical contact is 
maintained between the conduit and the welding power source enclosure. 
 
 

Содержание 155 SE

Страница 1: ...THERMAL ARC 155 SE USER S MANUAL...

Страница 2: ...ars if you respect all the operating and maintenance instructions given in this manual We strongly suggest you read very carefully chapters concerning safety and individual protection before using thi...

Страница 3: ...ding 8 1 2 2 5 Earthing of the workpiece 8 1 2 2 6 Screening and shielding 8 2 ELECTRIC SAFETY 8 2 1 CONNECTION OF THE WELDING POWER SOURCE TO THE NETWORK 8 2 2 WORKING AREA 9 2 3 INTERVENING 9 2 4 MA...

Страница 4: ...6 CONNECTION TO THE MAIN SUPPLY 15 7 CONNECTION TO THE GROUND 15 8 PRELIMINARY PRECAUTIONS 15 USING 16 9 DESCRIPTION OF THE FRONT PANEL 16 10 DESCRIPTION OF THE BACK PANEL 16 11 WELDING 17 MAINTENANC...

Страница 5: ...the manufacturer are not included in the guarantee Guarantee covers free of charge replacement of parts which have been admittedly defective transport included Every part replaced under guarantee will...

Страница 6: ...object of this manual complies with the following European regulations Electromagnetic compatibility Rule 89 336 EEC of 3 05 89 modified by rules 92 31 EEC of 28 04 1992 and 93 68 EEC of 22 07 1993 Lo...

Страница 7: ...es signalling and telephone cables above below and adjacent to the arc welding equipment b Radio and television transmitters and receivers c Computer and other control equipment d Safety critical equi...

Страница 8: ...r connected to earth because of its size and position e g ships hull or building steelwork a connection bonding the workpiece to earth may reduce emissions in some but not all instances Care should be...

Страница 9: ...d 14 12 1988 Art 4 2 3 INTERVENING Before carrying out any internal checking or repair work check that the power source has been separated from the electrical installation by locking and guard devices...

Страница 10: ...he additional advantage to protect the operator against burns caused by hot pieces and spatter This protective equipment should be kept in good order and checked on a regular basis 3 1 2 FACE AND EYES...

Страница 11: ...uring the welding process can be dangerous and hazardous to your health Arc welding works have to be carried out in suitable ventilated areas Ventilation must be adequate to remove gases and fumes dur...

Страница 12: ...sed combustible gaseous mixtures These are very light gases In the case of leaks they collect under the ceiling Provide for ventilation at ceiling level These are also inflammable gases The flame of h...

Страница 13: ...namic control of the welding current the specific protection of power components a high power in a small space at a very low power consumption THERMAL ARC 155 SE unit allows 2 possibilities of power s...

Страница 14: ...rrent A 32 23 Maximum power consumption kVA 3 7 5 3 Power factor cos 0 98 SECONDARY Off load voltage V 50 60 Welding current range A 3 120 3 150 Welding current at 35 A 150 Welding current at 60 A 130...

Страница 15: ...e operator s safety 7 CONNECTION TO THE GROUND For the operator s protection the power source must be correctly grounded according to the International Protections Norms It is absolutely necessary to...

Страница 16: ...S MANUAL Page 16 22 9 DESCRIPTION OF THE FRONT PANEL REPERE DESIGNATION F1 Welding current knob F2 Power terminal F3 Warning indicator F4 Power ON indicator F5 Power terminal 10 DESCRIPTION OF THE BA...

Страница 17: ...o the electrode polarity being used refer to the electrodes manufacturer s datasheets Start up the power source with the switch ON OFF B2 When you start the power source the orange indicator F3 illumi...

Страница 18: ...m the mains Voltages are high and dangerous inside the machine In spite of their robustness THERMAL ARC power sources require some regular maintenance Once every 6 months more often in dusty surroundi...

Страница 19: ...k back frame 2 V01002 Fan 12Vdc supply 3 B05025 ON OFF main switch 4 I05801 Chassis 5 I05812 Black front frame 6 E10207 TH Main PCB 7 T18107 Complete inductor 8 I05831 Cover 9 B00011 TH Front fascia 1...

Страница 20: ...ont panel potentiometer corresponding to pin 1 2 and 3 of J6 connector 15 TROUBLE SHOOTING POSSIBLE CAUSES CHECKING REMEDY GREEN AND ORANGE INDICATORS OFF NO SUPPLY ON OFF main switch is OFF Put the s...

Страница 21: ...16 WIRING DIAGRAM...

Страница 22: ...ermadyne Industries Ltd Italia Milan Italy Tel 39 039 204 991 Fax 39 039 204 9922 PTA Plasmatechnik Germany Westerburg Germany Tel 49 2663 915666 Fax 49 2663 915667 THERMADYNE INDUSTRIES reserve the r...

Отзывы: