background image

English 3

Step 3: INSTALLATION

1. Hold the blower on the wall. 

Note the direction of the air conduction.

2. Mark the 4 mounting boreholes.

At least one screw must be installed through a 

stud.

All hardware must be suitable for the wall’s 

construction materials.

3. Drill the 4 x ¼'' (6.35 mm) Ø mounting boreholes.

Insert wall anchors and screw the blower to the wall.

4. Connect the ducting from the blower to the extractor 

hood and feed to the outside.

5. Connect the blower to the extractor hood with an 

extension cable, if required.
Use the added connector to hard-wire to the blower, if 
required.
Use the wire diagram for connecting.

NOTE: 

Confirm that the blower is securely attached to the 

wall and all connections are secure.

WARNING

The additional cover on the plug must always be 
attached and closed for safety reasons.

Not needed wires must be isolated, capped with wire 
nuts and stored in a safe position.

19⅛" (485 mm)

19⅛" (485 mm)

19⅛" (485 mm)

15⅛" 

(384 mm)

15⅛" 

(384 mm)

15⅛" 

(384 mm)

10" 

(254 mm)

10" 

(254 mm)

10" 

(254 mm)

10" 

(254 mm)

10" 

(254 mm)

10" 

(254 mm)

12" 

(305 mm)

12" 

(305 mm)

12" 

(305 mm)

Содержание VTI1010P

Страница 1: ...VTI1010P VENTILATION BLOWER MOTOR INSTALLATION MANUAL MANUEL D INSTALLATION DU VENTILATEUR VTI1010P MANUAL DE INSTALACI N DEL VENTILADOR VTI1010P Models Mod les Modelos VTI1010P...

Страница 2: ...NSTALLATION 3 Wire Diagram 4 Customer Support Accessories Parts back page Safety Definitions NOTICE This indicates that damage to the appliance or property may occur as a result of non compliance with...

Страница 3: ...HE FOLLOWING a Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes and regulations including fire related construction b Sufficient air i...

Страница 4: ...l interlocking etc If the air intake is inadequate there is a risk of carbon monoxide poisoning from combustion gases which are drawn back into the room An air intake exhaust air wall box by itself is...

Страница 5: ...to the outside 5 Connect the blower to the extractor hood with an extension cable if required Use the added connector to hard wire to the blower if required Use the wire diagram for connecting NOTE C...

Страница 6: ...ish 4 Wire Diagram speed 1 red speed 2 blue speed 3 orange speed 4 brown N white PE green yellow NOTE If using a three speed hood connect speed 1 red speed 2 blue and speed 4 brown Cap off speed 3 ora...

Страница 7: ...TION 4 Sch ma de c blage 5 Entretien Pi ces et Accessoires page verso D finitions concernant la s curit NOTICE Ceci indique que la non conformit cet avis de s curit peut entra ner des d g ts l apparei...

Страница 8: ...ENT Afin de r duire le risque d incendie n utiliser que des conduits en m tal AVERTISSEMENT POUR R DUIRE LE RISQUE D INCENDIE DE CHOC LECTRIQUE OU DE PR JUDICE PHYSIQUE RESPECTEZ LES CONSIGNES SUIVANT...

Страница 9: ...l environnement et tous peuvent tre recycl s pour un usage ult rieur Veuillez contribuer prot ger l environnement et mettre les mat riaux d emballage au rebut dans le respect de l environnement Retir...

Страница 10: ...admission d air est mauvaise il existe un risque d intoxication par les gaz d gag s lors de la combustion qui sont r achemin s dans la pi ce Une ventouse d admission ou d vacuation d air fix e au mur...

Страница 11: ...r la hotte aspirante l aide d un c ble de prolongement si n cessaire Utilisez le connecteur pour proc der au c blage du ventilateur s il le faut Pour effectuer les branchements se reporter au sch ma d...

Страница 12: ...ne blanc orange bleu rouge marron vert jaune blanc orange bleu rouge marron vitesse 4 vitesse 3 vitesse 2 vitesse 1 vitesse 4 vitesse 3 vitesse 2 vitesse 1 NOTE Si vous utilisez une hotte trois vitess...

Страница 13: ...4 Diagrama de cableado 5 Servicio Piezas y Accesorios contraportada Definiciones de seguridad NOTA Esto indica que puede producirse un da o al electrodom stico o a la propiedad como resultado de la fa...

Страница 14: ...no use el ventilador con ning n dispositivo de control de velocidad de estado s lido ADVERTENCIA PARA REDUCIR EL RIESGO DE INCENDIO DESCARGA EL CTRICA O LESIONES A PERSONAS SIGA ESTAS INDICACIONES a E...

Страница 15: ...Ninguno de los materiales contamina el medioambiente y todos se pueden reciclar para volverse a usar Ayude a proteger el medioambiente y deseche el embalaje de manera ecol gica Retire toda la cinta y...

Страница 16: ...proco etc Si la entrada de aire es insuficiente existe un riesgo de intoxicaci n con los gases de la combusti n que vuelven a ingresar a la habitaci n Una caja de entrada salida de aire en la pared po...

Страница 17: ...r a la campana extractora con un cable de extensi n si fuera necesario Utilice el conector para conectar el ventilador si es necesario Use el diagrama de cableado para realizar la conexi n NOTA Aseg r...

Страница 18: ...arillo blanco naranja azul rojo marr n verde amarillo blanco naranja azul rojo marr n velocidad 4 velocidad 3 velocidad 2 velocidad 1 velocidad 4 velocidad 3 velocidad 2 velocidad 1 NOTA si se emplea...