Page |17
The divider between the
upper and lower drawers
feels warm.
Normal operation, as part of the
moisture control system for the
exterior of the unit.
No action required.
Hi-alarm is activated (due to
high temperature inside the
appliance), HI is shown on
the display LED.
Appliance opened frequently.
Do not open the appliance unnecessarily. Press
alarm once to deactivate.
The ventilation openings have
been covered.
Remove obstacles at the ventilation openings
located at the base of the unit and in the
refrigerator interiors. Press alarm once to
deactivate.
A large amount of product, or warm
product was placed into the
appliance.
Wait until the products cool off or remove the
warm products from the appliance, then press
alarm once to deactivate.
Excessively warm environment.
Avoid placing the unit in direct sunlight, or near a
heat source. Press alarm once to deactivate
Drawers gasket is not sealing.
Inspect the condition of the gasket. If damaged,
cold air can escape the cabinet and cause the
temperature to rise. Press alarm once to
deactivate.
Data Rating Label
The data rating label shows the model and serial number of your appliance. It is located at the right side of the bottom
compartment.
Service Information
For handy reference, copy the information in the form below from the data rating label located at the right side of the