Performance Data Sheet: Quick Connect Filter- SGF-W10
The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for
water leaving the system as specified in NSF/ANSI Standard 42 and Standard 53. System tested and certified by IAPMO R&T against NSF/ANSI Standard
42 and Standard 53 for the reduction of substances listed below.
Contaminant Reduction:
Operation Specifications:
Capacity- 122 Gallons (461 Liters)
Flow Rate- 0.5gpm
Water Supply- Potable Water
Water Pressure- 20 to 120 psi
Water Temperature- 0.6°C to 38°C [33°F to 100°F]
It is essential that the manufacturer's recommended installation, maintenance and filter replacement requirements be carried out for the product to perform
as advertised.
Note: While the testing was performed under standard laboratory conditions, actual performance may vary.
NOTICE To reduce the risk associated with property damage due to water leakage:
• Installation: Read and follow use instructions before installation and use of this system.
• Water Pressure: Do not install if water pressure exceeds 120 psi (8.2 bar). If your water pressure exceeds 80 psi, you must install a pressure limiting
valve.
• Water Temperature: Do not install on hot water supply lines. The maximum operating water temperature of this filter system is 100° F (38° C). Protect
filter from freezing. Drain filter when temperatures drop below 33°F (0.6°C).
•Replacing the Cartridge: The disposable filter cartridge should be replaced every 6 months at the rated capacity, or sooner if a noticeable reduction in
flow rate occurs.
• This filter is not intended to purify water. Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection
before or after the system.
• The substances removed or reduced by this water treatment device are not necessarily in all users' water.
Substance
Average Influent
Influent Challenge
Concentration
Average %
Reduction
Average Product
Water
Concentration
Max Permissible
Product Water
Concentration
Reduction
Requirement
CTO [NSF/ANSI 42]
Chlorine Taste and
Odor
2.0 mg/L
2.0 mg/L ± 10%
>99.9%
0.14 mg/L
N/A
>50%
HEAVY METALS [NSF/ANSI 53]
Lead
0.1496 mg/L
0.15 mg/L ± 10%
99.9%
0.002 mg/L
0.010 mg/L
N/A
Mercury
0.006 mg/L
0.006 mg/L ± 10%
99.9%
0.0005 mg/L
0.002 mg/L
N/A
VOC [NSF/ANSI 53]
Atrazine
0.3014 mg/L
0.009 mg/L ± 10%
>99.9%
0.002 mg/L
0.003 mg/L
N/A
Alachlor
0.3014 mg/L
0.050 mg/L ± 10%
>99.9%
<0.0002 mg/L
0.001 mg/L
N/A
Lindane
0.3014 mg/L
0.002 mg/L ± 10%
>99.9%
<0.00002 mg/L
0.0002 mg/L
N/A
2,4-D
0.3014 mg/L
0.210 mg/L ± 10%
>99.9%
0.002 mg/L
0.070 mg/L
N/A
P-Dichlorobenzene
0.3014 mg/L
0.225 mg/L ± 10%
>99.9%
0.002 mg/L
0.075 mg/L
N/A
Benzene
0.3014 mg/L
0.015 mg/L ± 10%
>99.9%
0.002 mg/L
0.005 mg/L
N/A
ALSO REDUCES [NSF/ANSI 53]
Toxaphene
0.0169 mg/L
0.015 mg/L ± 10%
96.9%
0.0008 mg/L
0.003 mg/L
N/A
Turbidity
11.17 NTU
11 + 1 NTU
97.3%
0.32 NTU
0.5 NTU
95.5%
Cyst
80,000 cysts/L
Minimum 50,000
cysts/L
99.9%
5 cysts/L
N/A
>99.95%
Asbestos
110 MF/L
107 to 108 fibres/L;
fibres greater than
10|jm in length
>99.99%
<0.01 MF/L
N/A
>99%