Recommended Grounding Method –
Models PRSG304 and PRSG36

The 30" and 36" all-gas ranges are factory equipped with a power supply
cord with a three-prong grounding plug (with polarized parallel blades).
IT MUST BE PLUGGED INTO A MATING GROUNDING TYPE RECEPTACLE
THAT IS CONNECTED TO A CORRECTLY POLARIZED 120 VOLT CIRCUIT.
(See Fig. 19). 

Improper grounding will cause malfunction (such as

continuous sparking of the burner igniters), may damage this appli-
ance, and could create a condition of shock hazard at the igniter of
each burner. 

If the circuit does not have a grounding type receptacle, it is

the responsibility and obligation of the installer or user to have the existing
receptacle changed to a properly grounded receptacle in accordance with
all applicable local codes and ordinances by a qualified electrician. In the
absence of local codes and ordinances, the receptacle replacement shall be
in accordance with the National Electric Code. 

THE THIRD GROUND

PRONG SHOULD NOT, UNDER ANY CIRCUMSTANCES, BE CUT OR
REMOVED.

Alternate Grounding Method –
Models PRSG304 and PRSG36

If installing a properly grounded wall receptacle is impossible at the time of
installation, consult your local electrical inspector for permission to
connect a temporary adapter (with polarized blades) which could be
plugged into your present 2-wire receptacle.
(See Fig. 20.) 

This method is not recommended.

If this is done, you must attach the lug and/or the green adapter wire to
the receptacle cover plate screw. Ground from it to a grounded metal cold
water pipe. (See Figures 20 and 21.)

DO NOT GROUND TO A GAS SUPPLY PIPE.

Grounding Method –
Models PRES304, PRSE36 and PRSE48

All ranges must be properly grounded.  See the grounding instructions for
your installation case, as follows.  Refer also to the instructions and
Figures on Pages 17 and 18.

CASE 1: Electrical Connection and Grounding with a 3 Conductor

Power Supply (To be used when local codes permit grounding
through the neutral.) 

 Secure the neutral, grounded wire of the

supply circuit to the neutral terminal of the NEMA 10-50R
receptacle.  Connect the L1 (black) and L2 (red) hot leads to the
other terminals on the NEMA 10-50R receptacle.  A separate
ground wire is not required.  Ensure that the house supply wires
and all electrical connections meet the requirements of all appli-
cable codes.

NO. 4 WIRE

CLAMP

METER

METAL WATER PIPE

CLAMP

RECEPTACLE

BOX COVER

PLATE

THREE-PRONG

RECEPTACLE

THREE-PRONG

PLUG

FIG. 20 Alternate

Grounding Method –
Models PRSG304 and
PRSG36

COVER

PLATE

THREE-PRONG

PLUG

GROUNDED

COLD WATER

PIPE

GROUND

WIRE

THREE-PRONG

ADAPTER

GROUND

WIRE

TWO-PRONG

RECEPTACLE

FIG. 19 Recommended

Grounding Method –
Models PRSG304 and
PRSG36

FIG. 21 Grounding to a Metal

Cold Water Pipe

STEP 6: ELECTRICAL REQUIREMENTS, CONNECTION & GROUNDING

Содержание PRSE36

Страница 1: ...t PRSE36 Models 120 240 VAC 60 Hz 1Ph 30 Amp circuit PRSE48 Models 120 240 VAC 60 Hz 1Ph 50 Amp circuit IMPORTANT Save these instructions for the Local Electrical Inspector s use INSTALLER Please leav...

Страница 2: ...capability Models PRSG364GD PRSG364GL and PRSG366 feature a gas cooking surface with four sealed burners and a griddle four sealed burners and a grill or six sealed burners in addition to a large capa...

Страница 3: ...00 549 For installations at 6 000 feet above sea level or higher it is necessary to de rate the appliance Contact your local gas STEP 1 VENTILATION REQUIREMENTS supplier or Thermador 800 735 4328 for...

Страница 4: ...d cabinets installed on either side of the hood is 13 5 Any openings in the wall behind the range and in the floor under the range must be sealed 6 When there is less than a 12 horizontal clearance be...

Страница 5: ...Trim 26 3 8 9 22 Provided with 30 Range Std Low Back Guard Optional High Shelf 42 Min to Combustibles 10 2 3 1 2 25 24 3 8 30 Ranges 24 3 8 36 48 Ranges 25 PRSG304 16 1 2 CAUTION Do not install the M...

Страница 6: ...y cord with a three prong grounding plug IT MUST BE PLUGGED INTO A MATING GROUNDING TYPE 120VAC RECEP TACLE THAT IS CONNECTED TO A CORRECTLY POLARIZED AND GROUND ED 120VAC CIRCUIT See STEP 6 The range...

Страница 7: ...tor should protrude no more than 2 1 4 inches from the rear wall See Figure 3d This is especially critical if the junction box in the wall will be directly behind the junction box on the unit when the...

Страница 8: ...the door to the fully open position Close the hinge latches See Fig 6 by rotating towards the oven The door can then be removed by gently lifting and pulling the door with the hinges up and out of th...

Страница 9: ...professional range must be level The range is leveled by adjusting the legs with a wrench Replace the kick panel and oven doors by reversing the procedure described above It is important that the two...

Страница 10: ...tion of the Anti Tip Device then turn off power to these circuits Failure to follow these instructions may result in electrical shock or other per sonal injury WARNING ALL RANGES CAN TIP INJURY TO PER...

Страница 11: ...ket may be attached to a solid wood cabinet having a minimum wall thickness of 3 4 The thickness of the wall or floor may require use of longer screws available at your local hardware store In all cas...

Страница 12: ...TEP C Slide the bracket left or right to the correct position for the model that you are installing The distance from the side wall to the center line of the closest mounting hole is 2 3 4 for Model P...

Страница 13: ...y slide the range into position FOR THE ANTI TIP CHANNEL TO ENGAGE THE MOUNTING BRACKET THE REAR EDGE OF THE RANGE SIDE PANEL MUST BE WITHIN 2 OF THE VERTICAL MOUNTING FLANGE OF THE ANTI TIP BRACKET A...

Страница 14: ...oor position the bracket such that the center line of the rear most mounting holes in the horizontal bracket flange are 7 16 in front of the rear edge of the range side panel when the range is in its...

Страница 15: ...has been permanently mounted within the range body Use 5 8 flex line to connect between the gas supply and the appliance manifold pipe which exits the upper left rear of the appliance The appliance m...

Страница 16: ...matics have been placed in the toe kick area of the range for access by a qualified service technician The PRSE Dual Fuel Ranges may be connected to a 120 208 VAC power supply Chart D POWER SUPPLY WIR...

Страница 17: ...eady equipped the cord must have 10 closed loop lugs attached to the free ends of the individual conduc tors preferable soldered in place Locate the junction box on the rear of the unit and remove cov...

Страница 18: ...outside terminal block studs brass colored with nuts 4 Tighten nuts securely 4 WIRE LEAD CONNECTION 1 Remove top nuts only from the terminal block studs Do not remove lower nuts which secure range in...

Страница 19: ...could be plugged into your present 2 wire receptacle See Fig 20 This method is not recommended If this is done you must attach the lug and or the green adapter wire to the receptacle cover plate scre...

Страница 20: ...quirements of all applicable codes DO NOT GROUND TO A GAS SUPPLY PIPE Improper grounding will cause malfunction such as continuous sparking of the burner igniters may damage this appliance and could c...

Страница 21: ...to increase air inlet grill griddle and gas oven only The sealed top burner flames should be approximately 1 to 1 1 4 high The griddle grill gas oven and infrared broiler burner flames should be as s...

Страница 22: ...Follow all cleaning by rinsing with clear water Wipe dry with a clean soft cloth to avoid water marks For discolorations or deposits that persist use a non scratching household cleanser or stainless s...

Страница 23: ...The porcelain grill rack is in place The stainless steel grill housing if equipped is in place The ceramic briquettes are placed on grill tray per instructions enclosed GAS SUPPLY Connection 1 2 N P...

Страница 24: ...Appliances Corp Litho U S A 4 01 We reserve the right to change specifications or design without notice Some models are certified for use in Canada Thermador is not responsible for products which are...

Отзывы: