Thermador PRSE36 Скачать руководство пользователя страница 14

Page 14

SIDE VIEW

FIG. 14 PRSE Wall Mount

FIG. 15 PRSE Floor Mount

PLAN VIEW

STEP B:

Set the bracket on the floor and turn it

until it is oriented properly. The long channel
should be on the top with the free end facing
towards you, one set of mounting flanges should
be resting horizontally on the floor, and the other
set of mounting flanges should be positioned
vertically facing the rear.

STEP C:

Slide the bracket to the desired position.

Note that the minimum (dim. A) and maximum
(dim. B) spacing from the side wall to the center
line of the closest bracket mounting hole is as
shown in the chart above and in Figures 14 and
15.

STEP D:

If you plan to mount the bracket to the rear

wall, slide the bracket back until it is positioned
against the rear wall. If you plan to mount the
bracket to the floor, position the bracket such that
the center line of the rear-most mounting holes in
the horizontal bracket flange are 7/16" in front of
the rear edge of the range side panel when the
range is in its final installed position.

STEP E:

With the bracket properly positioned, use

the bracket as a template and mark the location of
the selected four (4) mounting holes.

STEP F:

Drill four (4) holes at the marked locations.

STEP G:

Using the four (4) screws provided, securely

fasten the bracket.

STEP H:

Carefully slide the range into position.

 FOR

THE ANTI-TIP DEVICE TO ENGAGE THE RANGE,
THE REAR EDGE OF THE RANGE SIDE PANEL
MUST BE WITHIN 2" OF THE VERTICAL MOUNT-
ING FLANGE OF THE ANTI-TIP BRACKET. RE-
MOVE ANY LOOSE ITEMS SUCH AS GRATES
AND BURNER CAPS FROM THE TOP OF THE
RANGE, THEN CAREFULLY TILT THE RANGE
FORWARD TO ENSURE THAT THE ANTI-TIP
DEVICE ENGAGES TO PREVENT TIPPING.

Shown From

Left Side Wall

Max.

 up to 2

"

Shown From

Left Side Wall

7/16"

STEP 4:  INSTALLING ANTI-TIP DEVICE

Min. A

Max. B

Min. A

Max. B

Содержание PRSE36

Страница 1: ...t PRSE36 Models 120 240 VAC 60 Hz 1Ph 30 Amp circuit PRSE48 Models 120 240 VAC 60 Hz 1Ph 50 Amp circuit IMPORTANT Save these instructions for the Local Electrical Inspector s use INSTALLER Please leav...

Страница 2: ...capability Models PRSG364GD PRSG364GL and PRSG366 feature a gas cooking surface with four sealed burners and a griddle four sealed burners and a grill or six sealed burners in addition to a large capa...

Страница 3: ...00 549 For installations at 6 000 feet above sea level or higher it is necessary to de rate the appliance Contact your local gas STEP 1 VENTILATION REQUIREMENTS supplier or Thermador 800 735 4328 for...

Страница 4: ...d cabinets installed on either side of the hood is 13 5 Any openings in the wall behind the range and in the floor under the range must be sealed 6 When there is less than a 12 horizontal clearance be...

Страница 5: ...Trim 26 3 8 9 22 Provided with 30 Range Std Low Back Guard Optional High Shelf 42 Min to Combustibles 10 2 3 1 2 25 24 3 8 30 Ranges 24 3 8 36 48 Ranges 25 PRSG304 16 1 2 CAUTION Do not install the M...

Страница 6: ...y cord with a three prong grounding plug IT MUST BE PLUGGED INTO A MATING GROUNDING TYPE 120VAC RECEP TACLE THAT IS CONNECTED TO A CORRECTLY POLARIZED AND GROUND ED 120VAC CIRCUIT See STEP 6 The range...

Страница 7: ...tor should protrude no more than 2 1 4 inches from the rear wall See Figure 3d This is especially critical if the junction box in the wall will be directly behind the junction box on the unit when the...

Страница 8: ...the door to the fully open position Close the hinge latches See Fig 6 by rotating towards the oven The door can then be removed by gently lifting and pulling the door with the hinges up and out of th...

Страница 9: ...professional range must be level The range is leveled by adjusting the legs with a wrench Replace the kick panel and oven doors by reversing the procedure described above It is important that the two...

Страница 10: ...tion of the Anti Tip Device then turn off power to these circuits Failure to follow these instructions may result in electrical shock or other per sonal injury WARNING ALL RANGES CAN TIP INJURY TO PER...

Страница 11: ...ket may be attached to a solid wood cabinet having a minimum wall thickness of 3 4 The thickness of the wall or floor may require use of longer screws available at your local hardware store In all cas...

Страница 12: ...TEP C Slide the bracket left or right to the correct position for the model that you are installing The distance from the side wall to the center line of the closest mounting hole is 2 3 4 for Model P...

Страница 13: ...y slide the range into position FOR THE ANTI TIP CHANNEL TO ENGAGE THE MOUNTING BRACKET THE REAR EDGE OF THE RANGE SIDE PANEL MUST BE WITHIN 2 OF THE VERTICAL MOUNTING FLANGE OF THE ANTI TIP BRACKET A...

Страница 14: ...oor position the bracket such that the center line of the rear most mounting holes in the horizontal bracket flange are 7 16 in front of the rear edge of the range side panel when the range is in its...

Страница 15: ...has been permanently mounted within the range body Use 5 8 flex line to connect between the gas supply and the appliance manifold pipe which exits the upper left rear of the appliance The appliance m...

Страница 16: ...matics have been placed in the toe kick area of the range for access by a qualified service technician The PRSE Dual Fuel Ranges may be connected to a 120 208 VAC power supply Chart D POWER SUPPLY WIR...

Страница 17: ...eady equipped the cord must have 10 closed loop lugs attached to the free ends of the individual conduc tors preferable soldered in place Locate the junction box on the rear of the unit and remove cov...

Страница 18: ...outside terminal block studs brass colored with nuts 4 Tighten nuts securely 4 WIRE LEAD CONNECTION 1 Remove top nuts only from the terminal block studs Do not remove lower nuts which secure range in...

Страница 19: ...could be plugged into your present 2 wire receptacle See Fig 20 This method is not recommended If this is done you must attach the lug and or the green adapter wire to the receptacle cover plate scre...

Страница 20: ...quirements of all applicable codes DO NOT GROUND TO A GAS SUPPLY PIPE Improper grounding will cause malfunction such as continuous sparking of the burner igniters may damage this appliance and could c...

Страница 21: ...to increase air inlet grill griddle and gas oven only The sealed top burner flames should be approximately 1 to 1 1 4 high The griddle grill gas oven and infrared broiler burner flames should be as s...

Страница 22: ...Follow all cleaning by rinsing with clear water Wipe dry with a clean soft cloth to avoid water marks For discolorations or deposits that persist use a non scratching household cleanser or stainless s...

Страница 23: ...The porcelain grill rack is in place The stainless steel grill housing if equipped is in place The ceramic briquettes are placed on grill tray per instructions enclosed GAS SUPPLY Connection 1 2 N P...

Страница 24: ...Appliances Corp Litho U S A 4 01 We reserve the right to change specifications or design without notice Some models are certified for use in Canada Thermador is not responsible for products which are...

Отзывы: