Figure 3: Installation Clearances with a Flush Island Trim
as defined in the “National Fuel Gas Code” (ANSI Z223.1, Current Edition).
Clearances from non-combustible materials are not part of the ANSI Z21.1
scope and are not certified by CSA. Clearances of less than 12” (305 mm)
must be approved by the local codes and/or by the local authority having jurisdiction.
Combustible
Materials
27⅝” (702 mm)
27¼” (692 mm)
36" (914 mm) min
to combustible
materials
24” (610 mm)
max. recess depth
Cantilever
36¾” (933 mm) Max.
35⅞” (911 mm) Min.
23” (584 mm)
44⅞” (1140 mm)
Installation Clearances with Flush Island Trim
24⅝” (625 mm)
24¾” (629 mm)
NOTE: If an inner
wall is used under
the cantilever counter
top, there should be a
⅛” (3 mm) gap from
the rear of the range
to the inner wall.
NOTE: For Flush
Island Trim installations,
counter surface should
have a cantilever edge
meeting the back
section of the Flush
Island Trim accessory.
12” (305 mm) min. to
combustible surface
with Flush Island Trim